FRANKE FCS 90 O1 EV8 Hood User Manual
- June 12, 2024
- Franke
Table of Contents
FRANKE FCS 90 O1 EV8 Hood
Product Information
The product is a cooking appliance with various models, including FCS 90 O1 EV8, FCS 90 NF EV8, FCC 90 NF EGC, FCC 90 O2 EGC, FCL 90 NF EGC, FCL 60 A2 EGC, FCL 60 NF EGC, and FCL 90 A2 EGC.
It is equipped with an illumination system that uses a lamp with the following specifications:
- Power: 4W
- Socket: E14
- Dimensions: 107 x 37mm
- ILCOS Code: DRBB/F-4-220-240-E14-35/100
The product also features controls for the lighting system and the extractor motor. The extractor motor has three operating speeds: low, medium, and maximum. There are safety measures to be followed, including not touching accessible parts that may become hot during use and using self-shielded tungsten halogen lamps or self-shielded metal halide lamps for replacement. Care and maintenance instructions include cleaning the grease filters every 2 months (or more frequently for heavy usage) and replacing the activated charcoal filter every 4 months (or more frequently for heavy usage).
Product Usage Instructions
- Before installation and use, read the manual carefully for safety information and correct operation guidelines.
- Keep the manual with the appliance at all times, even if you move or sell it.
- Familiarize yourself with the operation and safety features of the appliance.
- Follow the regulations provided by local authorities for fume discharging.
- Do not use the product if you have reduced physical or mental capabilities, lack experience and knowledge, or without supervision or instruction.
- Switch on/off the lighting system using the L switch.
- Switch on/off the extractor motor using the M switch.
- Set the operating speed of the extractor using the V switch: 1. Low speed for continuous and silent air change with light cooking vapour. 2. Medium speed for most operating conditions. 3. Maximum speed for eliminating high cooking vapour emission.
- Clean the grease filters every 2 months (or more frequently for heavy usage) by washing them in a dishwasher.
- Replace the activated charcoal filter approximately every 4 months (or more frequently for heavy usage).
SAFETY INFORMATION
For your safety and correct operation of the appliance, read this manual carefully before installation and use. Always keep these instructions with the appli-ance even if you move or sell it. Users must fully know the oper-ation and safety features of the appliance.
- The wire connection has to be done by specialized technician.
- The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
- The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please refer to the paragraphs on working dimensions and installation).
- If the instructions for installa-tion for the gas hob specify a greater distance, this must be respected.
- Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
- Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
- For Class I appliances, check that the domestic power supply guarantees adequate earthing.
- Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
- Regulations concerning the discharge of air have to be fulfilled.
- Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
- If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker hood.
- The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
- If the supply cord is damaged, it must be replaced from the man-ufacturer or its service agent.
- Connect the plug to a socket complying with current regula-tions, located in an accessible place.
- With regards to the technical and safety measures to be adopted for fume discharging, it is important to closely follow the regulations provided by the local authorities.
- WARNING: Before installing the Hood, remove the protective films.
- Use only screws and small parts in support of the hood.
- WARNING: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.
- Do not look directly at the light through optical devices (binoculars, magnifying glasses…).
- Do not flambè under the range hood; risk of fire.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Children should be supervised to ensure that they do not play with the appliance.
- The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction.
- Accessible parts may become hot when used with cooking appliances.
- Clean and/or replace the Filters after the specified time period (Fire hazard). See paragraph Care and Cleaning.
- There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the ap-plicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
- “In case of replacement with halogen lamp use only self-shielded tungsten halogen lamps or self-shielded metal halide lamps.”
USE
- The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
- Never use the hood for purposes other than for which it has been designed.
- Never leave high naked flames under the hood when it is in operation.
- Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
- Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
CARE AND CLEANING
- The Activated charcoal filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage (W).
- The Grease filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher (Z).
- Clean the hood using a damp cloth and a neutral liquid detergent.
CONTROLS
L | Light | Switches the lighting system on and off. |
---|---|---|
M | Motor | Switches the extractor motor on and off. |
V | Speed | Sets the operating speed of the extractor: |
1. Low speed, used for a continu- ous and silent air change in the presence of light cooking vapour.
2. Medium speed, suitable for most operating conditions given the optimum treated air flow/noise level ratio.
3. Maximum speed, used for elimi- nating the highest cooking vapour emission, including long periods.
LIGHTING
Lamp| Power (W)| Socket| Voltage (V)| Dimension (mm)|
ILCOS Code
---|---|---|---|---|---
****| 4| E14| 220 – 240| 107 x 37| DRBB/F-4-220-240-E14-35/100
Franke S.p.a.
Via Pignolini, 2
37019 Peschiera del Garda (VR)
www.franke.it
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>