Specifications

  • Product: Trackunit TU700
  • Dimensions: W = 75 mm / 2.96 inches, H = 30 mm, L = 150 mm / 5.91 inches
  • Compatibility: Standard DTM12, Standard DTM12 + MODBUS DTM4, Standard DTM12 with M8 for Access Control, Flying Lead

Product Information

The Trackunit TU700 is a telematics device that provides stable, secure, and reliable connectivity for equipment and machinery.

Product Usage Instructions

Pre-installation

  • Before You Install: Read the Trackunit TU700 Safety Guide before installing.

  • Mounting Location
    Mount the Trackunit TU700 with the serial number facing outwards to avoid obstructing the LED Indicator.

  • Serial Number Location
    The Trackunit TU700’s Serial Number and mobile number are located on the box’s front. The label can be peeled off and saved for later use.

  • Mounting the Cradle
    The included cradle allows the TU700 to be mounted on a flat surface. Insert four M4 screws through the mounting holes and into the mounting surface.

  • Inserting the TU700
    Once the cradle is firmly mounted onto a surface, firmly snap the TU700 into place.

  • Installation Check and Update
    Visit install.trackunit.com to register and verify your unit. Install and activate the Trackunit Raw in an area with strong GPS and mobile coverage before verification.

Installation Guide

Wiring Diagram with Access Control:

Wire color Description
Power Connect to Machine battery through a fuse (Mandatory)
Input 1 Connect to the Hour Counter (Mandatory)

FAQ

  • Q: Where can I find help for installation and activation?
    A: You can find installation, activation, and onboarding info at helpcenter.trackunit.com.

  • Q: How do I contact customer support?
    A: Please reach out to our experienced support team at support@trackunit.com.

  • Q: How can I place an order for accessories or additional products?
    A: You can place your order at trackunit.com if you already know what you need.

Find the accessories you’re looking for.

Trackunit-TU700-IoT-Device- \(1\)

TU700 Shield Mount
Made to protect the TU700 in harsh environments, adding an extra layer of protection.

  • RFID Card Reader
    USB RFID card reader is a easy tool to activate K300 RFID card and DualID RFID card access for operators.

  • Trackunit RFID Cards
    The RFID card is an easy way to control access to your equipment through the K300 or DualID.

  • Splash Proof Relay
    Used when required, to interface the TU700 to specific machine wiring signals or controls.

  • Standard Relays
    Used when required, to interface the TU700 to specific machine wiring signals or controls.Trackunit-TU700-IoT-Device- \(2\)Ferrite
    Designed and certified for use in Japan with TU-501 and TU600-x models.
    Power Cable
    Versatile solutions to connect Trackunit Raw to any type of machine.
    Keypad Bracket
    Made to protect the K300 and DualID II in harsh environments by adding an extra layer of protec-tion. Trackunit-TU700-

Help is here. Whenever and however you need it.

Trackunit-TU700-IoT-Device- \(4\)

Trackunit TU700

The Different Ways of ConnectingTrackunit-TU700-IoT-Device-
\(5\)

Product Diagram

Overview
The TU700 is a telematics device providing stable, secure, and reliable connectivity.

 Product Dimensions

Trackunit-TU700-IoT-Device- \(6\)

  • Length: 150 mm (5.91”)
  • Width: 75 mm (2.95”)
  • Height: 30 mm (1.18”)
  • Weight: 150 g (5.29 oz.) (excl. cable)

Tech Specs

  • Network: LTE-M1 w/ NB-IoT & 2G GSM Fallback
  • Approvals: FCC, ISED
  • GPS: GPD, Galileo, Glonass, Beidou
  • Supply Voltage: 12 – 48 VDC
  • Max. Voltage Range: 9 – 58 VDC
  • Internal Battery: 3.6 V/800 mAh Li-ion
  • Temperature Range: -20C to +60C/-4F to +140F
  • Environmental Class: IP66, IP67, IP69
  • CAN Support: J1939 / CAN Open
  • Modbus Support: With Selected Wiring Harness
  • Bluetooth 5.0 BLE

Included

  • TU700
  • Mounting Cradle
  • Selected Wiring Harness
  • Fuseholder (only for free wire versions) / 1A Fuse
  • Installation & Safety Guides

Compatible With

Pre-installation

Before You Install

  • Read Safety Guide
    Read the Trackunit TU700 Safety Guide before installing.

  • Mounting Location
    Mount Trackunit TU700 with the serial number facing outwards, so you do not obstruct the LED Indicator.

  • Serial Number Location
    Trackunit TU700’s Serial Number and mobile number is located on the box’s front.
    Note : The label can be peeled off and saved for later use.Trackunit-
TU700-IoT-Device- \(8\)

  • Mounting the Cradle
    The included cradle allows the TU700 to be mounted on a flat surface. Insert four M4 screws through the mounting holes and into the mounting surface

  • Inserting the TU700
    Once the cradle is firmly mounted onto a surface, the TU700 is able to firmly snap into place. Trackunit-TU700-IoT-Device- \(9\)

Trackunit Manager

The TU700 is your direct link to Trackunit Manager. Trackunit Manager empowers fleet managers to boost efficiency, safety, and machine up-time. Get a complete view of everything you need – from high-level summaries to specific machine details.

Trackunit-TU700-IoT-Device- \(11\)

Installation Check and Update
Please visit install.trackunit.com to register and verify your unit. Before verification, install and activate the Trackunit Raw in an area with strong GPS and mobile coverage.

Installation

Installation Guide

Wiring Diagram with Access ControlTrackunit-TU700-IoT-Device-
\(13\)

  1. Supply voltage range 12 – 48 V
  2. Active/high when min. 5V DC at Input
  3. Max. Voltage: 48V
  4. Max. load 200 mA
  5. Do NOT use this output to switch off vehicles and machines during operation or driving

Trackunit-TU700-IoT-Device- \(14\)

Functionality Check

Trackunit-TU700-IoT-Device- \(15\)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals