CAMBRO Camcarriers Insulated Transporters Owner’s Manual
- June 4, 2024
- CAMBRO
Table of Contents
CAMBRO® INSULATED TRANSPORTERS
This manual applies to the following Cambro product lines:
OWNER’S
MANUAL
DURABILITY THAT MAKES A DIFFERENCE®
Introduction
Congratulations on the purchase of your new Cambro-insulated transporter. This
Owner’s Manual provides you with a step-by-step guide to assembling,
operating, and maintaining your transporter. If you have any further
questions, please do not hesitate to contact your Cambro Sales Representative,
visit our Web site at
www.cambro.com or call our Customer Service Line at
800 833 3003.
Parts and Assembly Instructions
(A) Pop-up Vent Cap and Anchor Installation and Use Instructions ⁄4 / 19.05mm)
opening with a Pop-up
Vent Cap & Anchor for equalizing pressure and releasing steam. * Lids and
doors manufactured by Cambro after March 2007, feature a large ( 3 To open
vent, firmly grasp the vent, and pull outward until you hear a click. To close
the vent, push the vent in until you hear a click.
To remove the Pop-up Vent components:
- Push the vent cap down into the non-venting position.
- From the bottom or inner side of the lid or door, unscrew the anchor component in a counterclockwise direction. You may need to hold the cap on the opposite side of the lid or door to stop it from turning.
- Once the anchor component is disconnected from the cap, pull up on the cap until it comes completely out of the vent opening.
To install the Pop-up Vent components :
- Place the cap component into the vent opening from the top or outer surface of the lid or door, pushing it fully into the opening until it stops (in the non-venting position).
- From the bottom or inner side of the lid or door, screw in the anchor component in a clockwise direction. You may need to hold the cap on the opposite side of the lid or door to stop it from turning. When the two components are fully connected, stop turning. Do not over-tighten. * UPCs and toploading Camcarriers ® feature a built-in vent, so these instructions do NOT apply to those models.
(B) Beverage Server Faucet and Spout Assembly Instructions
- Put a flat washer in the groove at the end of the spout.
- Place spout in Camtainer.
- Put a fiber washer on the spout. Push it to the wall of the Camtainer.
- Thread the hex nut and tighten the nut firmly, but do not over-tighten. (If the flat washer inside of the Camtainer is flattened and distorted, leaking can occur.) To tighten the hex nut, use the wing nut as a wrench.
- Leave the wing nut in the position used in step 4, the tightened position.
- Insert metal “C” ring in the front groove, in front of the wing nut.
- Insert faucet into the wing nut and tighten it in an upright position (counter-clockwise)
Faucet Kit
Spout Kit
Maintenance and Cleaning
Schedule a thorough, regular cleaning and parts inspection of doors, gaskets,
spigots, latches and hinges. Check to make sure they are in good working
condition or replace if necessary.
(A) Cleaning Instructions
-
Remove and clean lids, vent caps, gaskets, and spigots. To clean gaskets, place in a container or sink of hot, soapy water, wipe off with a soft cloth or brush, rinse with hot water, and dry with soft, dry cloth.
-
Where possible, remove doors and clean around hinges and/or pins.
-
Using a soft cloth or brush and a mild commercial cleaning detergent, clean the outside and inside, paying close attention to handles, latches, hinges and vent caps. Sanitizing
solutions are recommended. Do not use any cleaners containing ammonia or bleach. Do not use steel wool or abrasive pads or brushes. -
Rinse with clean hot water at 70ºF (21,1°C) or hotter.
-
Air dry whenever possible or wipe thoroughly with a dry, clean, soft cloth to remove all moisture inside and out.
-
Store with lids and doors slightly open.
(B) Removing Lingering Scents and Stains
- Use an odor-removing soak or sanitizer to remove scents and stains that can occur from holding coffee and/or foods with strong odors.
- A diluted solution of 2–3 tablespoons of baking soda per gallon of hot tap water or 1 part lemon juice or vinegar to 4 parts hot water is also an effective way to remove lingering odors.
- Rinse thoroughly with hot water and dry.
(C) Usage Tips and Precautions
Pre-heating or pre-chilling your transporter before loading is recommended for
best results and to extend holding time.
To preheat, slide a hot Cambro Camwarmer ® onto the bottom rails or place a
full-sized, uncovered pan of hot water onto the bottom rails. Close the door
for 15–30 minutes. Fill beverage servers with hot water, cover them, and latch
the lid for 15-30 minutes.
To pre-chill, slide frozen Cambro Camchiller(s) ® onto the top rails or slide
a full-sized, uncovered pan of ice water onto the top rails. Close the door
for 15–30 minutes. Another effective method is to place transporters in cooler
or freezer overnight with doors open or lids off. Fill beverage servers with
ice water, cover, and latch lid for 15-30minutes.
To help protect your Cambro insulated transporter, reduce the risk of employee
injuries, and eliminate unnecessary food waste:
- Do not use any type of canned/portable cooking fuel inside a Cambro transporter.
- Always cool metal pans or sheet pans for 30–60 seconds to 250ºF (121ºC) before placing them into the Cambro transporter or on any transporter surface.
- Boiling liquid 190ºF (88ºC) or hotter should not be poured directly into a Cambro transporter.
- Do not place the product against any direct heat source such as a hot oven or grill.
(D) Caster Maintenance (for Camcarts®and Wheeled Camcarriers®)
Caster maintenance should be performed each time your transporter has been
washed or steam-cleaned.
- Grease the swivel raceway of the caster using a lubricant such as Lubriplate #930-AA, Keystone #84EPXLT multi-purpose grease or equivalent. Apply grease using a grease gun with a needle nose adapter or a tube-type applicator such as Sta-lube Moly-graph Assembly Lube. These can be obtained at most auto parts stores.
- Use a light oil such as WD-40 on the hub. Check the caster for damage and test the caster spin and swivel rotation before returning to service.
Warranty
WARRANTY
Cambro warrants to the original buyer that if a product proves defective:
- Within 1 year from the date of manufacture, Cambro will replace the product free of charge; or,
- After 1 year and up to 2 years from the date of manufacture, Cambro will grant a credit of 2/3 of the replacement product; or,
- After 2 years and up to 3 years from the date of manufacture, Cambro will grant a credit of 1/3 of the original price towards a replacement product.
Replacement Parts
Please visit www.cambro.com for a complete list of
replacement parts.
TO ORDER REPLACEMENT PARTS:
- Call Cambro Customer Service at 800 854 7631 or
- Fax your order to 714 842 3430 or
- Call your local Cambro Representative or Distributor
© 2007 Cambro Manufacturing Company, 5801 Skylab Road,
Huntington Beach, CA 92647
714 848 1555
Toll Free 800 854 7631
Fax 714 842 3430
Customer Hot-Line 800 833 3003
UMIT0701 Printed in the USA REV 04/07
MANUFACTURING COMPANY
www.cambro.com
Documents / Resources
|
CAMBRO Camcarriers Insulated
Transporters
[pdf] Owner's Manual
Camcarriers, Insulated Transporters, Camcarriers Insulated Transporters,
Transporters
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>