sinop HP6000ZB-MA Ductless Heat Pump Interfaces Installation Guide

June 1, 2024
sinop

sinop HP6000ZB-MA Ductless Heat Pump Interfaces

sinop-HP6000ZB-MA-Ductless-Heat-Pump-Interfaces-
product

Technical Specifications:

  • Communication Protocol: Zigbee 3.0
  • Frequency: 2.4 GHz
  • Transmission Power: +20 dBm
  • Receiver Sensitivity: -108 dBm

Product Information

The HP6000ZB-MA Ductless Heat Pump Interface is designed to provide seamless integration and control for your ductless heat pump system. It features a button and LED indicator for easy operation and status monitoring.

Installation Instructions

  1. Warnings: Before starting the installation, ensure the circuit for the ductless heat pump is powered off at the main electrical panel.
  2. Open the front panel of the wall unit.
  3. Insert the interface into the dedicated port in the cover of the wall unit.
  4. Close the cover of the wall unit.

Adding Your Ductless Heat Pump Interface:

  1. Download the Neviweb app for iOS or Android and create an account.
  2. In the app, tap Add Device and follow the installation wizard steps.

Disconnecting Your Ductless Heat Pump Interface:

  1. From GT130 Gateway: Turn off the ductless heat pump circuit from the electrical panel, open the cover of the wall unit, then remove the interface from the dedicated port. Press and hold the button on the interface for 10 seconds or until the LED flashes red to indicate disconnection.
  2. From Neviweb: Access the device settings in Neviweb, click Delete, and confirm deletion to remove the device.

Warranty: The product is covered by a 3-year limited warranty.

For more detailed information, please visit our website.

FAQ

  • Q: How do I reset the interface?
    • A: To reset the interface, press and hold the button on the interface for 10 seconds or until the LED flashes red.
  • Q: Can I use multiple interfaces with one heat pump system?
    • A: Yes, you can use multiple interfaces with one heat pump system for enhanced control and monitoring capabilities.

Product Overview

TECHNICAL SPECIFICATIONS

Temperature ranges

  • Operation: 32 °F to 104 °F (0 °C to 40 °C)
  • Storage: -4 °F to 122 °F (-20 °C to 50 °C)

Communication

  • Protocol: Zigbee 3.0
  • Frequency: 2.4 GHz
  • Transmission power: +20 dBm
  • Receiver sensitivity: -108 dBm

Warnings

Before starting the installation, make sure that the breakers for your ductless heat pump are off at the main electrical panel!

INSTALLATION

  1. Open the front panel of the wall unit.
  2. Insert the interface into the dedicated port in the cover of the wall unit.
  3. Close the cover of the wall unit.

ADD YOUR DUCTLESS HEAT PUMP

ADD YOUR DUCTLESS HEAT PUMP INTERFACE TO THE GT130 GATEWAY AND NEVIWEB

  1. If you do not have an account yet, download the Neviweb app for iOS or Android to create an account and add your device.
    Get the app

  2. Tap the , then select “Add Device”.

  3. Follow the steps of the installation wizard.

DISCONNECT YOUR DUCTLESS HEAT PUMP INTERFACE FROM THE GT130 GATEWAY AND NEVIWEB

Disconnection from the GT130 gateway

To disconnect your interface from the GT130 gateway, turn off the ductless heat pump circuit from the electrical panel, open the cover of the wall unit, then remove the interface from the dedicated port located in the cover of the unit. Press and hold the button on the interface for 10 seconds or until the LED flashes red to indicate disconnection.

Disconnection from Neviweb

  1. Click on the device you want to disconnect.
  2. Click on the gear to access the settings.
  3. At the bottom of the page, click Delete.
  4. Click Delete in the dialogue box. The device will be removed from the devices page.

FCC Statement

Transmitter Module IC: 5123A-GM210P / FCC ID:QOQGM210P

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to thefollowing two conditions: (1) this device does not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

3-year limited warranty

SINOPÉ TECHNOLOGIES INC. warrants the components of their products against defects in material and workmanship for a 3 year period from the date of purchase, under normal use and service, when proof of purchase of such is provided to the manufacturer. This warranty does not cover any transportation costs that may be incurred by the consumer. Nor does it cover a product that has been improperly installed, misused or accidentally damaged. The obligation of Sinopé Technologies Inc., under the terms of this warranty, will be to supply a new unit and this releases the manufacturer from paying the installation costs or other secondary charges linked to replacing the unit or the components.