MAXWATT MX13000AS 13.5kVA Petrol Portable Generator User Guide

June 1, 2024
MAXWATT

MAXWATT MX13000AS 13.5kVA Petrol Portable Generator

MAXWATT MX13000AS 13.5kVA Petrol Portable Generator 

Instruction For Use

Instruction For Use

  1. ADD OIL: 1.6Litre SAE 10W-30
    Place unit on a flat surface. Remove the oil dipstick.With the funnel supplied add 1.6 Litre  SAE 10W-30 oil. Replace dipstick and tighten.

  2. ADD FUEL:
    Fill the fuel tank with clean unleaded petrol. Note that the fuel  tank capacity is 45 Litres. ****45 L


  3. STARTING THE GENERATOR:
    ****Instruction For Use

  4. Ensure that the generator is placed in a well ventilated area.

  5. Ensure that there are no electrical appliances plugged into the generator

  6. Turn the Fuel Switch to the “ON” position.

  7. Battery connection
    Fasten the black negative wire on the negative terminal of the battery

  8. (6 A) PUSH – BUTTON START:

  9. Press the Battery Switch (Red Switch) to the “ON” position.

  10. Press & hold the Start Button for 4 seconds and wait for the generator to start.

  11. Once the generator is running smoothly you can then connect the appliances.
    CAUTION:

  12. BE CAREFUL TO NOT OVERLOAD the generator.

  13. DO NOT PLUG THE GENERATOR DIRECTLY INTO A WALL SOCKET.
    (6 B) Remote Start:


  14. Press the Battery Switch (Red Switch) to the “ON” position.

  15. Press the “Start” Button on the Remote.

  16. TO STOP:

  17. Turn the Fuel Switch to the ”OFF” position.

  18. Turn “OFF” the Switch (Red Switch).

  19. Press the Push – Button Start.

  20. Hold down the Remote “STOP” button for 3 seconds.

  21. Disconnect the appliances from the generator.

NOTE
CAUTION
**** If the BATTERY SWITCH (RED SWITCH) is left in the “ON” when the generator is turned off, the Battery WILL run flat!

Safety Instruction

REVIEW AND UNDERSTAND YOUR OWNERS MANUAL AND ALL WARNINGS BEFORE RUNNING YOUR GENERATOR

Warning

Read and understand the operators manual thoroughly before operating the generator to avoid any serious injury or even death

Fire hazard do not add fuel while generator is on.

Generator is potential source of electric shock do not exposed to moisture rain or snow do not operate with wet hands or feet.

Exhaust fumes contains poisonous carbon monoxide gas that can cause unconsciousness are DEATH Operate investment ventilated outdoor areas away from open Windows are doors

Prior to connecting any appliance to the generator check the rating label of the appliance refer to manual for details

Do not exposed to rain are used in damped locations

DANGER

Using a generator indoors CAN KILL YOU IN MINUTES Exhaust fumes contain carbon monoxide This is highly poisonous gas you cannot see or smell

Never use inside home or garage EVEN if doors and windows are open

Only use outside and far away from Windows doors and vents