ADD OIL: 1.2 Litre SAE 10W-30
Place unit on a flat surface. Open the side access panel and remove dipstick. With the funnel supplied add 1.2 Litre SAE 10W-30 oil. Replace dipstick and tighten. -
ADD FUEL:
Fill the fuel tank with clean unleaded petrol.
Note that the fuel tank capacity is 27 Litres. -
STARTING THE GENERATOR:
- Ensure that the generator is placed in a well ventilated area.
- Ensure that there are no electrical appliances plugged into the generator. Turn the Fuel Switch to the “ON” position.
- A. PUSH – BUTTON START:
- Press the ENGINE Switch (Red Switch) to the “ON” position.
- Press & hold the Start Button for 4 seconds and wait for the generator to start.
- Once the generator is running smoothly you can then connect the appliances. CAUTION:
- BE CAREFUL TO NOT OVERLOAD the generator.
- DO NOT PLUG THE GENERATOR DIRECTLY INTO A WALL SOCKET.
4. B. Remote Start: - Press the ENGINE Switch (Red Switch) to the “ON” position.
- Press the “Start” Button on the Remote.
- TO STOP:
1)Disconnect the appliances from the generator.
2)Press the Push – Button Start.
3)Hold down the Remote “STOP button for 3 seconds.
4)Turn the Fuel Switch to the “OFF position. (The Fuel Switch can also shut down the generator’s electrical system)
- Turn “OFF the ENGINE Switch (Red Switch).
NOTE
CAUTION!
If the BATTERY SWITCH (RED SWITCH) is left in the “ON” when the generator is
turned ott, the Battery WILL run flat!
REVIEW AND UNDERSTAND YOUR OWNERS MANUAL AND ALL WARNINGS BEFORE RUNNING YOUR GENERATOR
WARNING
Never fill tank or use indoors. Oo NOT overtil fuel tank and always allow for
fuel expansion. Never fill tank while engine is running or hot Allow unit to
coal for 2 minutes prior to refueling. Keep generator and stored tuel away
from tire. sparks and cigarettes.
**** Generator produces powerful voltage that can cause death or great
physical harm. Never connect to a building’s electncal system unless a
transler switch has been installed by a certihed electncian. Generators pose
risk of shock especially # operated in damp or wet conditions.
Only operate generator outdoors as the engine gives off carbon monoxide, an
oderless and coloress gas. inhaling carbon monoxide will cause nausea,
fainting or possible death.
ANYONE using or servicing generator must read and follow all safety and
operation instructions provided in product manual Failure to follow
instructions may result an circumstances leading to death, injury and property
damage.
STOP
CAUTION! Your generator has been shipped without engine oil. DO NOT add
fuel or start the engine before adding oil. See owner’s manual for
instructions.
CRANKCASE CAPACITY:
10W-30 1.2 Liter of SAE 10W-30 oil