MEDiBrace MBR8-2 Far Infrared Heated Back Support Belt
Please read this manual carefully and retain for future reference.
Product Introduction
Front
Back
Components:
- Button Controller & Charge Port
- Built-in Battery Compartment
- Plastic Rigid Stents
- Compression Straps
- Far-Infrared Graphene Heated Pad (internal)
- USB Cable
Specification
Name Model No.| Belt Size| Suggested Waist Fit| Weight|
Rated Power| Input Parameter| Battery Capacity
---|---|---|---|---|---|---
MEDi Brace® RAY-D8 v2
MBR8-2| 3XL 1450235mm
2XL XL L
1300235mm
1200235mm
1100230mm
M 1060230mm
S 910230mm| 112-129cm
102-119cm
94-110cm
82-96cm
72-86cm
54-76cm| 720g±10g
660g±10g
625g±10g
580g±10g
560g±10g
520g±10g| 10W| 5V 2A| 6000mAh
Note: “Belt Size” is for reference only, manual measurement, (error:
1-2cm).
“Suggested Waist Fit” based on circumference of body at the navel point (sizes
overlap each other)
Back Support Operation
-
Prepare by loosely attaching the compression straps (4) to the main belt, or leave them hanging down freely.
-
Wrap the main belt around your waist with the badge to your right side. Press end of belt at point (B) against your stomach.
-
Pull end (A) over (snug fit, but not too tightly) to connect to the Velcro on belt end (B). The function of this connection is to wrap and hold the belt firmly in position around your body.
There should be no abnormal pressure on main belt Velcro points. If you’re struggling to pull and stretch to connect A & B together, the belt is too small for you. -
Firmly grip both ends of the compression straps (4), pull and stretch them forward together at the same time, attaching them to the main belt. The function of these straps is to compress the belt and the stents (3) firmly against your back to provide the required lumbar support.
You can adjust the level of compression that feels most comfortable by detaching and repositioning the straps.
Don’t stretch and position the straps so tightly that the compression restricts natural blood flow or cause undue pain or pressure to your back.
It’s not recommended to wear the belt whilst sleeping.
FIR Heat Operation
-
Press and hold down the button for 3 seconds to power ON the RAY-D8. The red indicator light is displayed first. This is the highest setting where the temperature will reach 65-70 degrees.
-
Clicking the button multiple times will cycle through the additional settings. For example the next short press of the button will switch the RAY-D8 to mid-range where the orange indicator light appears. The temperature here is 55-60 degrees.
-
A third press of the button will switch the RAY-D8 to its lowest setting where the yellow indicator light is displayed and the temperature is 45-50 degrees.
We’re all unique and each person’s skin tolerance is different. It’s recommended to begin on the lowest setting and not exceed 45 minutes the first session.
It’s recommended to wear over thin cotton clothing. -
To power OFF the RAY-D8, press and hold down the button for 3 seconds.
For safety reasons, the RAY-D8 will automatically power OFF after a period of approximately 30 minutes.
Red Light 65-70°C High Temperature
Orange Light 55-60°C Medium Temperature
Yellow Light 45-50°C Low Temperature
Charging Operation
When the battery has 20% charge remaining, the light begins to flash and it’s time to re-charge.
-
Press and hold down the button for 3 seconds to power OFF
Do not use the RAY-D8 whilst charging. Remove the device from your body and set aside to re- charge. -
Insert the included USB cable (6) into any standard 5V charging adaptor.
-
Insert the type-c interface part of the cable into the charging port (1) on the RAY-D8 (under the button).
When plugged in and charging, the red light flashes.
Yellow flashing indicates the battery is fully charged.
Never store with the battery completely discharged.
For optimal use charge and discharge once per month.
Cleaning Instructions
Apply a slightly damp cloth if you need to clean your RAY-D8.
DO NOT IMMERSE IN WATER ~ KEEP DRY
The internal battery and wiring are not accessible. Immersing in water will
damage or destroy the device
Safety Warnings
Do not use this
device if you are taking strong pain medication or if you have any open sores
or wounds.
This product should not be used by children.
Persons who are hyper-sensitive to heat, pregnant, have bone diseases, skin allergies, heart disease, abnormal blood pressure, suffer epilepsy, implants (such as cardiac pacemaker), or osteoporosis should exercise special caution when using this device or seek guidance from your physician or GP.
Although this product is perfectly safe at its operating temperatures, if you feel any discomfort, stop using it.
Internal battery cannot be treated as general waste.
Dispose of the battery according to local regulations.
Executive Standard: ROHS 2.0 CE UKCA
Security Category: REACH
Customers Support
Manufacturer: ProfessorZ Ltd., 128 City Road, London EC1V 2NX, UK
Tel: +44 20 8123 6664
AF Pharma Service Europe SL, Muntaner 281
08021, Barcelona, Spain ~
info@afpharmaservice.com
LOT# / Date of Issue: 24/08/2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>