Rgdood A01 Rechargeable Wrist Blood Pressure Monitor with Voice Broadcast User Manual
- June 1, 2024
- Rgdood
Table of Contents
- A01 Rechargeable Wrist Blood Pressure Monitor with Voice Broadcast
- Name and function of each part
- Display screen
- How to wear wrist blood pressure monitor
- Correct measuring posture
- Precautions for measurement
- Measurement of blood pressure
- view memory value
- Turn voice on / off
- Select user
- Product troubleshooting
- Matters needing attention
- Technical parameter
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
A01 Rechargeable Wrist Blood Pressure
Monitor with Voice Broadcast
User Manual Version:
V3.1
A01 Rechargeable Wrist Blood Pressure Monitor with Voice Broadcast
- thank you for purchasing our products.
- please read the product manual carefully before use. It can make you better use the product.
- please keep the instruction manual, certificate of conformity and warranty card properly.
Thank you for purchasing the wrist-type fully automatic digital blood pressure monitor. This product BP 102 is specifically designed for home use for adults and elders. It has simple operation, High Definition LED, memory reading and other functions. Please read the operation manual before use.
Name and function of each part
Display screen
How to wear wrist blood pressure monitor
- remove the ornament worn on the wrist, wear the wrist strap of the sphygmomanometer on the wrist, and place the display o the front of the wrist.
- the wrist strap should be firmly wrapped around the wrist, and the edge of the wrist strap should be 1~2 cm away from the wrist
- please keep quiet during measurement, keep the ‘sphygmomanometer at the same height as the heart, and do not move or speak. Please avoid the following gestures during measurement
1. When measuring, the palm should extend naturally, and do not bend or clench the fist. 2. Do not hold your wrist or sphygmomanometer with your other hand. 3. Do not wear the product on the back of the hand or the side of the wrist
Correct measuring posture
1. Please sit in a room suitable for blood pressure measurement. Your body should be relaxed and natural. You should Sit in a chair with your feet on the ground. Keep your body straight and your back straight. (2), As shown in the figure below, please keep the sphygmomanometer at the same height as your heart. Incorrect measurement posture will affect the measurement of blood pressure. Blood pressure will vary according to posture, time and other factors. It is recommended to measure blood pressure with the same posture at the same time every day.
Precautions for measurement
a) Vigorous exercise, smoking or consumption of stimulants / sedatives (such
as coffee or alcohol) are not allowed 30 minutes before blood pressure
measurement.
b) Before measurement, please resting a comfortable and stable environment for
at least five minutes.
©) Itis usually measured in a sitting position.
d) The same hand should be fixed for each measurement.
e) Blood pressure shall be measured at least twice every time, with an
interval of not less than five minutes; Different individual health states may
require longer intervals.
f) Patients with arrhythmia and arteriosclerosis should be professionally
diagnosed by medical personnel,
Measurement of blood pressure
a ). after wearing the sphygmomanometer in the correct posture, turn the power switch to the “on” direction, all the LED lights will be on, and then press the touch button of the product, and the sphygmomanometer wil start measuring. Do not move or speak during measurement. b). after the product’s voice broadcast (with voice function) is completed, it starts to automatically pressurize to measure blood pressure. First, it wil pressurize to about 60mm Hg higher than its own sphygmomanometer, and then start to automatically deflate. The whole process is about 35 seconds to 55 seconds. According to the actual situation of blood pressure, the test time will change; c). when the product pressure drops to a certain extent, the measurement results appear on the LED display screen, with systolic blood pressure displayed at the top, diastolic blood pressure displayed in the middle and heart rate displayed at the bottom;
view memory value
After the test is completed, when the test record is displayed on the LED, if you press and hold the touch key for 3 seconds, you can view the test record and first display the average value of the last three test results. In this mode, short press the touch key to view the next group of memory values (the memory group number s displayed at the heart rate position), press and hold the touch key for 3 seconds to exit and CIose.
Turn voice on / off
In the standby mode, press and hold the touch key for 3 seconds to enter the setting mode. First, tum on or off the voice prompt function, and then briefly press the touch button to select whether to tun on or off the voice prompt function.
Select user
Turn the power switch to on state, press the start key for a long time, and
release the key after the “user icon” on the LCD starts flashing.
When the “user icon” s flashing, short press the start button to cycle the
measurement user.
About product charging instructions:
a). When the product is in use, if the power is low and the low power symbol
is on, please charge the product i time. When the power s to0 low, the product
may not be used, or the deviation of test results may be too large.
b).When charging, the charging indicator on the LED flashes green. When the
power supply is full
The LED charging indicator is always green.
c). Charging input voltage: DCSV; Current: 1A;
d). Please do not measure blood pressure during charging.
Product troubleshooting
Abnormal phenomenon | reason | Troubleshooting |
---|
The measurement result is
too high or too low| Sphygmomanometer is not at the same height as the head|
Maintain correct posture and re measure
Move or speak while measuring| Keep quiet and do not move during measurement
Tight wrist or arm muscles| Relax and re measure
The wristband is too loose or fight| Wear the wristband correctly
The product cannot be
pressurized| The product has air leakage| Contact customer service center
The measurement results are
different at different times| People’s blood pressure will change at different
times| Please take the measurement at the same lime every day Please relax
during the measurement
Shutdown during
measurement| Product power is too low| Please remeasure after charging the
product
Unable to start measurement| Product power is too low| Please to measure after
charging the product
Power switch not on| Remeasure after turning on the power switch
Product error code corresponding fault
Er 1 | Sensor calibration failed |
---|---|
Er 2 | Measurement error, measurement signal instability |
Er 3 | Abnormal measurement results |
Er 4 | Inflation is too slow or the product leaks |
Er 5 | Pressurization too fast |
Er 6 | Excessive interference in measurement |
Er 7 | Pressure exceeding 295mmHg |
Matters needing attention
a)-The measurement results are only for reference, which is dangerous for self
diagnosis. Please refer to the doctor’s advice.
b)-Self diagnosis may worsen the condition.
c)- Diabetes, hyperlipidemia and hypertension may accelerate arteriosclerosis
and may also cause circulatory disorders,
d)-The patient’s wrist and upper arm pressure values may vary.
e)- For patients with severe hypertension o serious blood disease, please use
it under the guidance of a doctor
f) Keep babies or people who cannot express themselves away from the machine.
g)- Please do not use it for other purposes than blood pressure measurement
h)- Keep the product away from live objects
i) – Please keep away from high-voltage equipment and signal transmitting
devices to prevent errors due to interference
J)- Please do not disassemble the host or maintain it by yourself
K)-Please do not start measuring until the product is worn to the wrist
l)-Do not use corrosive liquid to wipe the product surface
Technical parameter
Display Mode | Multi color LED |
---|---|
Measuring Method | Oscillography method |
Measuring Range | Pressure: 0-280mmHg (0-37.3KPa) |
Pulse: 40-185 times / minute
Measurement Accuracy| Pressure: ± 3 mmHg (t0.4KPa)
Pulse: ± 5% (of the Read value)
Use Environment| Temperature: +5-+40 C Humidity: 15-85%
Storage Environment| Temperature: -10-+55’C Humidity: 10-93%
Wrist Range Can Be Measured| About 13.5-19.5cm
Weight| About 107g
Memory capacity| 2 users .99 group memory
Unit of measurement| mmHg , KPa
Measurement content| Systolic blood pressure, diastolic blood pressure, pulse
Operating atmospheric pressure| 80-105 KPa
Stored atmospheric pressure| 50-105 KPa
Power Supply| Built in lithium battery
Charging mode| TYPE-C
Automatic shutdown| No operation for 60 seconds ± 15 seconds
Key type| Touch key
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>