Sentry H2O CP-SWS Sentry Wellness System Instructions
- June 2, 2024
- Sentry H2O
Table of Contents
Sentry H2O CP-SWS Sentry Wellness System
Sentry Wellness System Contents (P/N: CP-SWS)
- 1 Pre-Installed White Bracket
- 2 Clear Housings with O-Rings
- (Labels indicate the corresponding filter)
- 1 Catalytic Carbon Filter
- 1 Trappsorb Drop-In Filter
- 1 In-Line Pressure Relief Valve (PRV)
- 1 1/4” Tubing for Cold Water-to-Inlet
- Connection (with PRV installed in-line)
- 1 1/4” Tubing for Outlet-to-Faucet
- Connection (with male brass fitting)
- 1 Wrench
- 2 Screws (for mounting to wall)
- Verify you have the necessary components listed above before starting installation.
Tools Needed (Not Included)
- 1-2 Adjustable Wrenches/Pliers
- Drill with a Philips Head Drill Tip
- Scan to watch the installation video or visit SentryH2O.com
Instructions
IMPORTANT
DO NOT REMOVE PLASTIC WRAP FROM FILTERS UNTIL STEP 2.
STEP 1
Choose a location for installation (i.e. cabinet wall next to your fridge)
and mount the system bracket using the provided screws. We recommend using a
sharpie or pen to mark the mount points, then drill the screws, and then place
the system bracket on the screws.
STEP 2
Remove plastic wrap from filters and place the filters into their
corresponding housings. The Catalytic Carbon Filter MUST be placed into the
Catalytic Carbon Housing on the left side of the system and the Trappsorb
Drop-In Filter MUST be placed into the Trappsorb Housing on the right side of
the system. Unwrap and place each filter one at a time to avoid mixing them
up. Tighten the housings closed by hand and then use the provided wrench to
snugly fit the bowls to the lid, typically an ⅛-¼ turn, until the labels are
facing forward.
STEP 3
Identify the water source for your fridge and turn the water valve counter-
clockwise (OFF) to the off position. This valve should remain off for the
entire installation process.
STEP 4
Using an adjustable wrench, remove the fridge line from the water valve.
Position a container beneath the valve to catch water from the line.
STEP 5
Locate the provided cold water-to-inlet connection tubing with the PRV
valve installed and the female crush collet. With the PRV arrow facing towards
the system, push the tube into the cold water valve. Tighten the collet to the
valve by hand and then use the adjustable wrench to fully tighten. Tug on the
line to ensure a tight fit.
STEP 6
Using the provided outlet-to-faucet tubing with the male brass fitting,
thread the brass fitting onto the fridge line (this is the line that was
removed from the cold water valve in Step 4). Tighten by hand and then use 1
or 2 wrenches to fully tighten. Tug on the line to ensure a tight fit.
STEP 7
Using the cold water valve tubing from Step 5, push the tube end into the
Inlet Head (Catalytic Carbon Housing lid) until the tube bottoms out or can no
longer be pushed in. Tug on the tube to set the connection. Then push the
outlet-to-faucet tubing from Step 6 into the Outlet Head (Trappsorb Housing
lid) until the tube bottoms out. Tug to ensure tight fit.
STEP 8
Restore the water flow by turning the water valve clockwise (On) with your
faucet on. Check for leaks at the fitting locations or bowl gasket locations.
If there is a leak, either the tubes need to be pushed in further or the
housings need to be Re-Seated. We recommend checking at this point and then
again once you turn off your faucet.
STEP 9
Keep the cold water running for 5-10 minutes to purge the system of excess
carbon dust and trapp sorb dust. If the water appears cloudy and doesn’t taste
sweet, continue to purge the system for another 5 minutes. As the system
normalizes, you may notice reduced water pressure for up to one week.
STEP 10
Replace both filters annually and enjoy your new Wellness System!