NICOR TAC Select LED Troffer Instruction Manual
- June 4, 2024
- NICOR
Table of Contents
TAC SELECT LED TROFFER
INSTALLATION INSTRUCTIONS
TAC Select LED Troffer
The installation must only be performed by a licensed electrician.
To prevent death, injury or damage to property, this product must be installed
in accordance to National Electrical Code (NFPA70) in the US or Canadian
Electrical Code (CSA 22.1) in Canada.
Disconnect power before installing the product or servicing it.
Wait until fixture has cooled down before installing or servicing the fixture.
MIN. 90°C SUPPLY CONDUCTORS
What’s In The Box
Tools Needed
This LED Troffer requires very few tools for installation. A drill or a screwdriver and a pair of wirecutter.
1 Carefully unpack the fixture from its packaging. Inspect product for defects
due to shipping.
| 2 Locate desired positioning for fixture in ceiling grid. Remove ceiling
tiles if necessary.
---|---
3 Turn off power to appropriate circuit at the breaker panel.
| 4 Place fixture into the T-grid ceiling panel. Bend T-grid tabs up and out
and secure fixture to structure and/or grid per state and local codes.
5 Remove cover plate from power supply junction box by removing the screw and
lifting out the cover. Remove knockout(s) as needed.
| 6 Feed wiring through cover plate knock-out and connect wiring as shown.
Grey and purple wiring are for 0-10V dimming systems. Cap off if not used.
7 Reattach cover plate of junction box and secure with the screw.
To adjust CCT or Lumen output, set the switch positions on the back of the
fixture to the desired settings.
Note: 1) Power selection switch is a three-position switch that will
adjust light output: low/medium/high. 2) CCT selection switch is a three-
position switch that will adjust Color Temperature between 3500K, 4000K, or
5000K.| 8 Turn power on and verify that the troffer is lit.
LED EXPRESS LIMITED WARRANTY
Subject to the exclusions below, each NICOR LED product, including the LED
electronics and components of a property-installed NICOR LED product, will be
free from defect in materials and workmanship for a period of ve (5) years
from the original date of purchase. The product shall be considered defective
only if 10% or more of the product’s LED components fail. NICOR LED product
warranty covers the following performance criteria: LED Light Output will be
maintained above 70% of initial output; LED color temperature will not shift
more than 200K in CCT; LED driver will operate within NICOR specications; and
the extra nish, excluding natural aluminum or brass products, will not exhibit
cracking, peeling, excessive fading, or corrosion during the warranty period.
Exceptions apply as defined in NICOR’s product specification sheets, which are
incorporated by reference herein.
This limited warranty is provided to you, the purchaser of the product
identified on Seller’s invoice, as your exclusive remedy and applies only to
NICOR products that have been purchased from an authorized NICOR Distributor;
the product was new and in an unopened NICOR package at the time of
installation; and the NICOR product was installed by a licensed electrician or
under the supervision of a licensed electrician and used by consumers in the
United States or Canada when accompanied with this warranty. This warranty
extends only to the first consumer purchaser and is not transferable. A
consumer wishing to invoke the terms of this limited warranty must first
obtain a RGA number within 30 days of discovery of the defect and return the
product to NICOR for inspection. Once verified to be covered by this limited
warranty, NICOR will, at its sole discretion, repair, replace, or refund the
purchase price of any product that does not conform to this limited warranty.
If NICOR, at its sole discretion, determines that the product should be
repaired or replaced, this warranty is limited to the reasonable, customary,
and necessary costs and expenses associated with the repair/replacement. This
warranty requires that all repair/replacement estimates and costs, including
but not limited to equipment rental (if any), and any other cost or expense to
be incurred in the repair/replacement of the product, be approved in advance
and in writing by NICOR.
FAILURE TO OBTAIN NICOR’S ADVANCE WRITTEN APPROVAL OF ALL REPAIR/REPLACEMENT
COSTS AND EXPENSES IN WRITING SHALL VOID THIS LIMITED WARRANTY.
THIS LIMITED WARRANTY DOES NOT COVER THE FOLLOWING:
- Defects or damages resulting from improper installation, operation, storage, misuse or abuse, accident, or neglect;
- Defects or damages resulting from improper service, testing, adjustment, installation, maintenance, alteration, connection to out-of-specification electrical service, corrosive or damp environments, or connection to incompatible equipment or devices (e.g., connecting non-dimmable lighting products to dimmers);
- Damage which occurs in transit;
- Power surges or overheating due to external conditions
- Acts of nature including but not limited to lightning strikes
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO
THE DURATION OF THIS LIMITED WARRANTY, OTHERWISE, THE REPAIR, REPLACEMENT, OR
REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY
OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED. IN NO EVENT SHALL NICOR BE LIABLE, WHETHER IN CONTRACT OR IN TORT
(INCLUDING NEGLIGENCE) FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE
PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OF
ANY KIND, OR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS OR OTHER FINANCIAL
LOSS ARISING OUT OF OR IN CONNECTION WITH THE ABILITY OR INABILITY TO USE THE
PRODUCT TO THE FULL EXTENT THESE DAMAGES MAY BE DISCLAIMED BY LAW.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
SHARE YOUR EXPERIENCE WITH US
SCAN the QR or visit
www.nicorlighting.com/support/survey
FOLLOW US
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107
P: 800.821.6283
F: 800.892.8393
www.nicorlighting.com
September 24, 2019 10:09 AM rev 1.0
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>