INSTALLATION INSTRUCTIONS
TPC Select LED Troffer
**** The installation must only be performed by a licensed electrician.
To prevent death, injury or damage to property, this product must be installed
in accordance with National Electrical Code (NFPA70) in the US or the Canadian
Electrical Code (CSA 22.1) in Canada.
Disconnect power before installing the product or servicing it.
Wait until the fixture has cooled down before installing or servicing the
fixture.
MIN. 90°C SUPPLY CONDUCTORS
What’s In The Box
One (1) TPC Select Edgelit LED Troffer
Tools Needed
This Edgelit LED Troffer requires very few tools for installation. A drill or
a screwdriver and a pair of wire cutters. Sheet metal screws can be used to
attach the fixture to the T-grid or framing.
-
Carefully unpack the fixture from its packaging. Inspect product for defects due to shipping.
-
Locate the desired position for the fixture in the ceiling grid. Remove ceiling tiles if necessary.
-
Turn off power to the appropriate circuit at the breaker panel.
-
Bend grid mounting tabs.
-
Place the fixture into the T-grid ceiling panel. Secure to structure and/or grid per state and local codes.
-
Remove the access plate from the junction box (do not discard it) by removing the screws.
-
Connect wiring as shown.
-
Reattach the cover of the junction box and secure it with the screw. To adjust CCT or Lumen output, set the switch positions on the side of the driver to the desired settings.
Note:
- Power selection switch is a three-position switch that will adjust light output: low/medium/high.
- CCT selection switch is a three-position switch that will adjust Color Temperature between 3500K, 4000K, or 5000K.
- Turn the power on and verify that the panel is lit.
LED EXPRESS LIMITED WARRANTY
Subject to the exclusions below, each NICOR LED product, including the LED
electronics and components of a property-installed NICOR LED product, will be
free from defects in materials and workmanship for a period of ve (5) years
from the original date of purchase. The product shall be considered defective
only if 10% or more of the product’s LED components fail. NICOR LED product
warranty covers the following performance criteria: LED Light Output will be
maintained above 70% of initial output; LED color temperature will not shift
more than 200K in CCT; LED driver will operate within NICOR specifications;
and the extra nish, excluding natural aluminum or brass products, will not
exhibit cracking, peeling, excessive fading, or corrosion during the warranty
period. Exceptions apply as defined in NICOR’s product specification sheets,
which are incorporated by reference herein.
This limited warranty is provided to you, the purchaser of the product
identified on the Seller’s invoice, as your exclusive remedy and applies only
to NICOR products that have been purchased from an authorized NICOR
Distributor; the product was new and in an unopened NICOR package at the time
of installation; and the NICOR product was installed by a licensed electrician
or under the supervision of a licensed electrician and used by consumers in
the United
States or Canada when accompanied by this warranty. This warranty extends only
to the first consumer purchaser and is not transferable. A consumer wishing to
invoke the terms of this limited warranty must first obtain an RGA number
within 30 days of discovery of the defect and return the product to NICOR for
inspection. Once verified to be covered by this limited warranty, NICOR will,
at its sole discretion, repair, replace, or refund the purchase price of
any product that does not conform to this limited warranty. If NICOR, at its
sole discretion, determines that the product should be repaired or replaced,
this warranty is limited to the reasonable, customary, and necessary costs and
expenses associated with the repair/replacement. This warranty requires that
all repair/replacement estimates and costs, including but not limited to
equipment rental (if any), and any other cost or expense to be incurred in the
repair/replacement of the product, be approved in advance and in writing by
NICOR.
FAILURE TO OBTAIN NICOR’S ADVANCE WRITTEN APPROVAL OF ALL REPAIR/REPLACEMENT
COSTS AND EXPENSES IN WRITING SHALL VOID THIS LIMITED WARRANTY.
THIS LIMITED WARRANTY DOES NOT COVER THE FOLLOWING:
- Defects or damages resulting from improper installation, operation, storage, misuse or abuse, accident, or neglect;
- Defects or damages resulting from improper service, testing, adjustment, installation, maintenance, alteration, connection to out-of-specification electrical service, corrosive or damp environments, or connection to incompatible equipment or devices (e.g., connecting non-dimmable lighting products to dimmers);
- Damage that occurs in transit;
- Power surges or overheating due to external conditions
- Acts of nature including but not limited to lightning strikes
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO
THE DURATION OF THIS LIMITED WARRANTY, OTHERWISE, THE REPAIR, REPLACEMENT, OR
REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY
OF THE CONSUMER AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED. IN NO EVENT SHALL NICOR BE LIABLE, WHETHER IN CONTRACT OR IN TORT
(INCLUDING NEGLIGENCE) FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE
PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR
CONSEQUENTIAL DAMAGES OF ANY KIND, OR LOSS OF REVENUE OR PROFITS, LOSS OF
BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE
ABILITY OR INABILITY TO USE THE PRODUCT TO THE FULL EXTENT THESE DAMAGES MAY
BE DISCLAIMED BY LAW.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
THANK YOU
FOR YOUR PURCHASE
SHARE YOUR EXPERIENCE WITH US
SCAN the QR or
visitwww.nicorlighting.com/support/survey
https://www.nicorlighting.com/support/survey/
FOLLOW US NICOR, Inc. 2200 Midtown Place NE,
Albuquerque,
NM 87107 P: 800.821.6283
F. 800892.8393
www.nicorlighting.com
September 9, 2019 3:24 PM rev 1.0