Specifications
- Probe Number of Temperature Sensors: 5 (4 Internal and 1 Ambient)
- Temperature Range: Varies based on the specific sensors
- Accuracy: Not specified
- Resolution: Not specified
- Device Base Display: 2.4 TFT LCD
- Dimension Water Resistance: IPX2
- Dimensions Water Resistance: IP67
- Bluetooth Distance: >230 ft / 70m (outdoor), >66 ft/20m (enclosed cookware)
- Probe Material: Stainless Steel
- Battery Connection: 3.7 volt 3020 mAh
- Sleep Mode: The device will automatically enter the default Sleep Mode after 30 minutes if the Probe is removed
Important Safeguards
Please read this entire manual before using your Typhur Sync. Failure to follow these instructions could result in property damage or bodily injury.
CAUTION
- DO NOT use the Probe when cooking at temperatures above 572°F / 300°C or directly above hot coals or open flame.
- DO NOT place the Device Base unit directly on the grill cover or close to any hot surface.
- DO NOT use the Probe in a microwave or pressure cooker.
- DO NOT use cleaning products containing alcohol, ammonium, benzene, or abrasives, all of which could damage the device.
- DO NOT submerge the Probe in water for long periods.
- DO NOT run the Probe under cold water immediately after cooking. Let the probe cool down prior to washing.
The Device Base is NOT waterproof and should not be submerged in water or placed in the dishwasher. The probe is SHARP! Care should be exercised when handling the probe. This appliance should NOT be used by or near children or individuals with certain disabilities. If the Probe falls into a fire or direct heat source, turn off the cooking appliance and close the lid immediately. Allow the Probe to cool completely before removing.
Carefully remove the Probe from the cooked meat, taking caution as it may be
hot.
The Device Base shall only be supplied with safety extra-low voltage (SELV)
corresponding to the marking on the appliance.
SAVE THESE INSTRUCTIONS
Diagram
-
Ambient Temperature Sensor
(Ambient Max 572 ℉ / 300 ℃) -
Internal Temperature Sensor 1 – 4 (Internal Max 212 ℉ / 100 ℃)
-
Safety Notch
-
Stainless Steel
-
High-density Zirconia Ceramic Handle
Overview
- 2.4″ TFT Screen
- Touch Capacitive Control
- Type-C USB (5V 1400mA minimum required)
- Probe Icon Identify each Probe through the color of the handle
- Stand
Specifications
Using for the First Time
- Before using your Typhur Sync, ensure the product is fully charged and you have reviewed the important safety information.
- Download the free Typhur App for iOS or Android.
- Insert the probe completely into the meat, ensuring that it passes the Safe Notch and that the 4 internal sensors are in the center of the meat.
Operation
Panel Instruction
Power Control
Power On: To power on the Device Base, press the “O” button for 3
seconds. The Device Base will activate and the buttons will illuminate.
-
Power Off: Press and hold the “O” button for 3 seconds to shut down the screen. When cooking, select “Stop” on the screen prompt of ” Stop the Current Cooking ” to power off the Device Base. The Probe will automatically power off after 30 minutes of being plugged into the Device Base.
-
Sleep Mode: The Device Base automatically enters default Sleep Mode after 30 minutes of Probe inactivity. The default Sleep Mode time can be changed via the Typhur App.
When in Sleep Mode, the display turns off, the “<” and “>” buttons cease to illuminate, and the “O” button emits a pulsing light. -
Screen Lock Mode: The screen will enter locked mode after 30 seconds of inactivity on the main page. To unlock the screen, simply touch any key. The screen will then return to its previous state.
Pair the Typhur App
For first-time use, tap “Pair” directly on the Device Base.
- Open the Typhur App on your smartphone or tablet.
- Tap on “Device” and select “Add Device”. Select Typhur Sync and follow the instructions to pair your device.
Connectivity
Wi-Fi connection (highly recommended) The device will actively connect to Wi-
Fi when within range of a Wi-Fi signal. This ensures that the Typhur App
instantly receives any messages from the Probe. The device will display the
signal strength of the currently connected Wi-Fi network through the “Wi-Fi”
icon.
Bluetooth connection
The device can also connect to and push messages to the Typhur App via
Bluetooth. However, this connection method does not guarantee that the app
will receive all messages instantaneously. Please note that the Wi-Fi
connection is more reliable than the Bluetooth connection.
Restore Factory Settings
Press “<” and “>” simultaneously for 5 seconds to enter the “Reset” mode.
Follow the prompts to complete the operation.
Cooking
Temperature Setting
Unplug either Probe to be used, and the Device Base’s screen will display the
“Set Temp” prompt.
Set the target temperature: Press the “O” button on the Device Base to select the desired cooking temperature, within the selectable range of 105 – 212°F. Insert the probe before setting the temperature.
You can adjust your temperature unit preference via the Typhur App.
Temperature Adjustment
While cooking, you can press the “O” button to access the “Settings” to adjust
the target temperature.
Stopping Cooking
Press the “O” button, access the “Settings” menu, and select “Stop the Current
Cooking”.
Cooking States
Remove from heat: This state indicates that the food should be removed
from the heat source.
Resting: The food has entered a resting state, allowing the residual heat to continue to rise.
Ready: The food is cooked and ready to be served. Click “O” button to end the cooking process.
Trouble Shooting
Certifications
- Contains FCC ID: 2A6RN-WT1000
- Contains IC: 28517-WT1000
- FCC ID: 2A6RN-WTP1000
- IC : 28517-WTP1000
For Europe:
- The frequency band of operation is 2400 to 2483.5 MHz.
- Maximum transmit power less than 20 dBm EIRP.
[Shenzhen Typhur Technology Co., Ltd] hereby declares that the radio equipment
type [WT03] complies with Directive 2014/53/EU. The full text of the EU
Declaration of Conformity is available at the following Internet address:
https://explore.typhur.com/ce-declaration
[Shenzhen Typhur Technology Co., Ltd] hereby declares that the radio equipment
type [WT03] complies with Radio Equipment Regulations 2017. The full text of
the declaration of conformity is available at the following internet address:
https://explore.typhur.com/ce-declaration.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CAUTION: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Radiation Exposure Statement
The device complies with RF specifications when used near your body at a
distance of 10 mm. Ensure that the device accessories, such as a device case
and device holster, are not composed of metal components. Keep the device away
from your body to meet the distance requirement.
FCC Supplier’s Declaration of Conformity Product Name: Typhur Sync Wireless Thermometer
- Model number: WT03
- Supplier Name : Typhur Inc.
- Supplier Address (USA): 2890 Zanker Rd, Suite 120, San Jose, CA 95134
- Suppliers contact mail: allen.f@typhur.com
ISED Statement
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science, and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with Industry Canada radiation exposure limits set forth for an uncontrolled environment.
ISED Radiation Exposure Statement
The device complies with RF specifications when used near your body at a
distance of 10 mm. Ensure that the device accessories, such as a device case
and device holster, are not composed of metal components. Keep the device away
from your body to meet the distance requirement.
This symbol, affixed to the product or its packaging, indicates that the product must not be processed with household waste. It must be brought to an electric or electronic waste collection point for recycling and disposal. By ensuring the Appropriate disposal of this product you also help in preventing potentially negative consequences for the environment and human health. The recycling of materials helps preserve our natural resources. For further information regarding the recycling of this product, please contact your municipality, local waste disposal center, or the store where the product was purchased.
Support
Please contact our Customer Support Team if you have any questions.
- 1(888) 838-6563 (USA)
- support@typhur.com
- www.typhur.com/contact-us (USA),
- uk.typhur.com/contact-us (UK)
Typhur Privacy Statement
We value your privacy and personal data rights, and we, Typhur Inc. are the
entity responsible for the collection, use, and disclosure of information
under our Privacy Statement. For more details, please visit https://www.ty-
phur.com/privacy-statement.
Terms of Service
- For details about Typhur’s Terms of Service, please visit https://www.typhur.com/terms-of-service
- Refund & Return Policy
- Typhur has a 30-calendar day hassle-free return policy.
- For more details please visit: https://www.ty-phur.com/refund-and-return
Limited One-Year Warranty
- This appliance carries a limited one-year warranty against defects from the date of purchase.
- Full details are stated in Typhur’s warranty policy at www.typhur.com/warranty.
FAQ
- Q: Can I submerge the Device Base in water?
- A: No, the Device Base is not waterproof and should not be submerged in water or placed in the dishwasher.
- Q: How do I know when to replace the Probe?
- A: If the Probe falls into a fire or direct heat source, turn off the cooking appliance and close the lid immediately. Allow the Probe to cool completely before removing. Carefully remove the robe from the cooked meat, taking caution as it may be hot.
- Q: Can children use this appliance?
- A: This appliance should NOT be used by or near children or individuals with certain disabilities.
References
- phur.com - This website is for sale! - phur Resources and Information.
- phur.com - This website is for sale! - phur Resources and Information.
- phur.com - This website is for sale! - phur Resources and Information.
- Contact Us | Typhur
- Warranty Policy | Typhur
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>