Proxim SX5-1040A Wireless Corporation Stratum User Guide
- May 15, 2024
- proxim
Table of Contents
Proxim SX5-1040A Wireless Corporation Stratum
Specifications
- Model: StratumTM X5 Series
- Throughput: Gigabit-plus
- Antenna : MIMO 4×4, integrated or external (software switchable)
- Applications: High-capacity backhaul, video surveillance, multipoint deployments
IMPORTANT
For regulatory information and the latest product updates, including firmware
and the MIBs, please visit Proxim’s support site at
http://support.proxim.com.
The device must be installed by a trained professional who is familiar with
radio frequency
Introduction
- The Stratum™ X5 is a highly efficient radio endpoint that delivers gigabit-plus throughput in both point-to-point and multipoint wide area network configurations.
- Able to operate in MIMO 4×4, with either an integrated or external antenna (software switchable on some variants), the Stratum™ X5 is ideally suited to high-capacity backhaul, high-resolution video surveillance, or high-density multipoint deployments.
- Powered by Proxim WORP® (Wireless Outdoor Router Protocol), managed via web GUI, CLI, Bluetooth-enabled Proxim BlueConnect™ and SNMP for ProximVision® Advanced, this high-speed platform offers advanced Quality of Service, granular service level management, and very secure networking.
Products Covered in This Guide
Model
SX5-1040A| SX5-1042A
Package Contents
Each shipment includes the items listed in the following table. Please verify that you have received all the parts in the shipment, prior to the installation.
Device Overview
The device contains the following features (not all features are available for every variant)
Item | Features | Description |
---|---|---|
1 | Ethernet Port-1 | • 2.5 Gbps Ethernet |
• 802.3at/bt PoE In
2| Ethernet Port-2| • 1 Gbps Ethernet
• 802.3at PoE Out
3| SFP+ Port| • SFP+ Port with 10 Gbps Data transfer
4| Access Port| • 12v External DC IN Supply
A1,A2, A3&A 4| 5 GHz Antenna Ports (A1,A2,A3&A4)| • A provision to
connect external antenna in MIMO 4×4 mode.
• Connect A1 to Antenna Vertical Polarity port and A2 to Antenna Horizontal Polarity port.
• Connect A3 and A4 to Antenna Slant Polarity ports.
5| GPS Connector| • A provision to connect passive GPS antenna for device
positioning.
6| View LEDs & RSSI
LEDs Display
| • Displays boot up information (see View LEDs section).
• RSSI LEDs behavior Information (see RSSI LEDs Behavior Section).
7| Mounting Holes| • A provision to connect 10000-UMK mounting kit.
8| Hose Clamp Slits| • A provision to attach hose clamps (1/2 inch or
12 mm width)
for pole mounting.
9| Grounding Points| • A provision to ground the device.
Important: Stratum X5-1042A device includes a Quad polarization 18 dBi panel antenna which is enabled by default. To use an external antenna instead, switch to external antenna mode via the BlueConnect application or Web GUI. Refer to the antenna switching procedure in the Device Management Guide.
Weatherproofing RJ45 Connection
The following steps explain how to weatherproof the RJ45 connection:
- Use an outdoor-rated CAT5e/CAT6 cable with a straight-through terminated on both ends.
- Insert the CAT5e/CAT6 cable through the Sealing Nut (D) and install the Compression Washer (C) to the cable. Compression Washer (C) has a slit in the middle for quick installation onto the cable.
- Install the parts (D) and (C) in the direction as shown in Figure 2.
- Insert the Flat Washer (A) onto the Connector Body (B) and then insert the CAT5e/CAT6 cable through the Connector Body (B).
- Connect the cable end of the RJ45 connector to the Ethernet port of the device
- Make sure that the locking latch of the RJ45 Connector is properly inserted into the Ethernet port.
- Fasten the Connector Body Assembly to the Device Ethernet port hole and fully tighten it.
- Slide and Insert the Compression Washer (C) into the Connector Body Assembly.
- Fasten the Sealing Nut (D) to the Connector Body Assembly and fully tighten it to weatherproof the cable.
Additional Weatherproofing Steps
To add layer of protection to connectors against the environment, do the
following:
- Wrap vinyl tape in a half-lapped fashion, from the weatherproof connector end and continue wrapping down 3 inches onto the CAT5e/CAT6 cable.
- Next, wrap a layer of the butyl mastic tape over the adhesive side of the tape, covering all ofthe tape and connector.
- Wrap a final layer of vinyl tape over the butyl layer and cover the entire tape assembly.
- Place a small zip tie over the last wrap of tape to prevent it from unwrapping over time.
For a detailed explanation of RJ45 connectors and RP-SMA connections weatherproofing, refer to Stratum TM X5 Series Hardware Installation Guide at http://support.proxim.com.
Assemble the Mounting Hardware
- Fix the Mounting Plate (A) onto the bottom of the device using the provided screws and washers such that the antennas will be vertically and horizontally polarized when mounted; also, it is recommended to partially fasten the screws with washers into all the mounting holes, before final tightening of each screw. Torque the screws to 75 Lbf-in (86 Kgf-cm)
- Fix the Extension Arm (B) to the fixed Mounting Plate (A) with the provided bolt, nut, and washers. The Extension Arm (B) gives the device more possible tilt, letting you adjust for azimuth or elevation over a larger angle.
Mount the Device
- To pole-mount the device, insert the provided bolts through Bracket (D), mate with Bracket (C) around the pole, and secure with supplied washers torquing to 100 Lbf-in (115 Kgf-cm). The supplied screws (Hex. Cap 5/16” x 4” long) are designed for pole diameters from 32 to 89 mm (1.25 to 3.5 inches).
- Fix the fixed Extension Arm (B) to the Mounting Bracket (C) with the provided bolt, nut, and washers. Partially tighten the joints J1 and J2 to allow for alignment of the device.
- Once satisfied with the alignment, tighten the assembled parts by applying torque 130 Lbf-in (150 Kgf-cm).
- While installing the device, make sure that the device Ethernet Port-1 with cable installation (using cable gland) faces downward only as shown in Figure 5 below:
- To wall-mount the device, mount the bracket (C) to a wall by using 4 screws (not supplied), as shown figure below shown:
Plug in the Cables
Note: Unscrew the sealing cap port cover for installation of cables.
- Plug one end of the straight-through Cat5e/CAT6 cable into the Ethernet Port-1 of the device by following the Weatherproofing steps explained under section Weatherproofing RJ45 Connections. Connect the other end of the cable to the OUT / PoE port on the PoE Injector.
- Plugging in the second Cat5e/CAT6 cable to the Ethernet Port-2 is optional. Note: 56V DC (30 W maximum) is available on the Ethernet Port -2; hence, ensure that the connected device is rated to use the above voltage and maximum power.
- When PoE IN receives 56V DC, PoE OUT delivers the same voltage, i.e., 56V DC.
- By default, the Ethernet Port- 2 is for Data only; however, it is possible to enable the PoE OUT and Data feature through Web configuration. Please make sure to disconnect the Ethernet Port -2 cable from the PC before enabling this feature
- To connect the device through a hub or a switch to a Personal Computer, connect an Ethernet cable between the network interface card in the Personal Computer and the hub, and between the hub and the RJ45 IN / LAN port on the PoE Injector.
- To connect the device directly to a Personal Computer, connect an Ethernet cable between the network interface card in the Personal Computer and the RJ45 IN / LAN port on the PoE Injector.
- The PoE Power injector is a Gigabit Ethernet port and can supply up to 60 Watts.
Note: Optional 2.5/5 Gbps 802.3bt PoE injector is available (Part Number: 949-00147), place an order separately with your distributor.
Install Surge Protector
StratumTM X5 Series comes with built-in Ethernet surge protection; however, it is mandatory to install an approved lightning surge protector at the building ingress point. Moreover, if you are installing the device in a region subjected to violent thunderstorms or severe weather conditions, then installation of an additional approved lightning surge protector near the device is recommended.
Note : To buy an additional Surge Protector (Part Number: 235- 00001),
place an order separately with your distributor
Perform the following steps to ensure proper surge protection
-
Mount a surge protector near the building ingress and use 10AWG or larger wire to connect the surge protector’s lug to the earth’s ground.
-
The outdoor device and co-located surge protector should have a common grounding point using the shortest possible grounding cable.
Note: Use Outdoor-rated, UV-protected, shielded CAT5e/CAT6 cable for the following. -
Connect an RJ45 terminated cable between the indoor equipment and the port on the surge protector at the building ingress
-
Connect an RJ45 terminated cable between the surge protector and the outdoor device on Ethernet Port-1.
IMPORTANT: Ensure to loop the cable before entering the premises to prevent water ingress.
Ground the Device
To ensure proper grounding, attach a ground wire of at least 12 AWG stranded to the device at either of the ground points which are located at the bottom corners of the device and use the grounding screw provided. It is important to follow the grounding guidelines below to protect the device against lighting or ESD events:
- Connect one end of the grounding cable to the device and the other end to the closest earth-ground point at the installation site.
- Remove any extra ground wire length when finished connecting it to the single point earth ground.
- Avoid sharp bends, loops or coiling the ground wire, always connect it straight to the ground.
- A proper earth ground impedance is less than 1.0 ohm.
- Measure ground impedance at the point where the surge protector ground wire is connected and not at the grounding rod.
- Connect the surge protector ground wire and equipment ground (both power ground and telecom ground) to a single common ground.
- Make sure all connections are fastened securely and tight.
- Never install a link during a storm and always follow your local safety codes.
Power on the Device
After connecting the PoE Injector and the device using a straight-through
CAT5e/CAT6 cable plug the power cord into a power outlet. There is no ON/OFF
switch on the device. To power down the unit, unplug the RJ45 connector from
the OUT / POE port on the PoE injector.
View LEDs
When the device is powered on, it performs startup diagnostics. When startup
is complete, Ethernet LEDs show the device’s Ethernet state
LED State | Off | On |
---|---|---|
1G | Ethernet Port-2 not connected | Ethernet link is established |
2.5G | Ethernet Port-1 not connected | Ethernet link is established |
PWR | Power is Off | Power is ON |
RSSI LED Behavior
During the first two minutes, after the device is turned on or rebooted, the
unit LED indicators provide the following information
LED State | Off | On |
---|---|---|
RSSI_LED-1 (Lower) | Power is OFF | Power is ON |
RSSI_LED-2 | Wireless 1 (5 GHz) is OFF | Wireless 1 (5 GHz) is ON |
RSSI_LED-3 | N/A | N/A |
LED State | Off | On |
--- | --- | --- |
RSSI_LED-4 | Flash is corrupted (requires RMA) | Flash is Ok |
RSSI_LED-5 (Higher) | Ethernet is DOWN | Ethernet is UP |
Initialize the Device
You can configure the IP address of the device by using HTTP, SNMP, CLI or
Proxim’s ScanTool. For remote management of a device using the Proxim
BlueConnect application, refer to the procedure given in the Device Management
Guide at http://support.proxim.com.
Bluetooth Key: 123456
The following are the default access values of the device:
- Default IP address : 169.254.128.132
- Subnet Mask: 255.255.255.0
- Gateway: 169.254.128.132
- Username: admin
- Password: public
- SNMP Read Write Community String: public
Download Software and Documentation
To download the Software and Documentation, please visit the Proxim support
site at http://support.proxim.com. Once you log on, select the product
category StratumTMX5 Series from
Product Downloads Page and links to the latest software, SNMP MIB file and
documentation will beavailable for download from the StratumTMX5 series
download and documentation page.
Note: You need Acrobat Reader to view the PDF documents.
Technical Support
- Proxim Customer Support Web site is available 7x24x365 at http://support.proxim.com
Telephone Support
- US and Canada: +1-408-383-7700; +1-866-674-6626
- International: +1-408-383-7700
- Business Hours: Tier 1 support: 24×7 live response.
- Tier 3 support: 8 a.m. to 5 p.m. M-F PST (UTC/GMT -7 hrs).
FAQ
- Q: How do I switch to external antenna mode on Stratum X5-1042A?
- A: Use the BlueConnect application or Web GUI as per the antenna switching procedure in the Device Management Guide.
- Q: What is the torque requirement for tightening mounting screws?
- A: Torque the screws to 75 Lbf-in (86 Kgf-cm).
CONTACT
Proxim Wireless Corporation
- ADDRESS: 2114 Ringwood Ave, San Jose/ CA 95131, USA.
- Troll Free: + 1 800-229-1630
- Phone: + 1 408-383-7600
- Fax: +1 408-383-7680
- http://www.proxim.com
P/N 765-00419 Version 1.0
WORP Driving the Internet of Things®
Copyright © 2023 Proxim Wireless
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>