Introduction
The SGW2828-EVK is a evaluation kit (Figure 1) designed for the development and Proof-of-concept testing of applications based on the SGW2828-01A LoRa Module. With the associated PC software, testing is easily enabled when two or more users are connected and using the same frequency channel. The PC software is supported by Windows operating systems (Windows 10).
Required Tools
The SGW2828 Module’s long-range and wall-penetrating capabilities are best
demonstrated when testing is conducted with at least two individual users.
Each user should be equipped with the following:
a. SGW2828-EVK LoRa Evaluation Kit
b. +2dBm SMA antenna
c. Micro-USB cable
d. PC with Windows 10 or above
e. SGW2828-EVK PC Tool program
Operation Guide
a. Preparation
- Download the SGW2828-EVK PC software file at https://www.sgwireless.com/uploads/prod-uct/files/SGW2828%20PC%20Tools%20V1.5.1.zip. Extract the file for the SGW2828-PC-Tool program.
- Prepare the SGW2828-EVK by screwing on the antenna, then connect the SGW2828-EVK to the PC with the micro USB cable (Figure 2). Toggle the power switch to ON.
- Run the SGW2828-PC-Tool program.
b. Configuration of PC Software
-
Select the COM port number assigned for the connected SGW2828-EVK, then click ‘Connect’. The COM port number may be different for each user, and can be found through Device Manager > Ports (COM & LPT) (Figure 3).
Remarks: If the desired COM port number is not showing in the drop-down menu, click ‘Refresh’. -
Configure the RF Parameter, if needed. Users can use the default parameter settings or configure theirown at Menu > Configuration > RF Parameter (Figure 4). Data transmission is enabled when users use the same parameter settings.
• ‘Read’: Read current parameter settings of connected SGW2828-EVK
• ‘Write’: Save customized settings
• ‘Fast Rate’/’Normal’/’Long Range’: Use pre-configured settings
• ‘Default’: Reset to default settings
Table 1: Preset Parameters
Pre-configured Parameters| Fast Rate| Normal| Long Range|
Default
---|---|---|---|---
Preamble| 16| 16| 16| 16
Bandwidth| 500kHz| 250kHz| 125kHz| 250kHz
Code Rate| 1| 1| 4| 1
SF| 7| 9| 12| 7
Hop Period| 0| 0| 0| 0
Channel| 0| 0| 0| 0
TxPow| -4dB| 4dB| 4dB| 4dB
c. User Application Mode
User Application mode enables several tests for the SGW2828-EVK capabilities
and proof-on-concept development:
i. LED ON/OFF
ii. Text
The PC Tool is set to User Application mode by default, and can be accessed in
Engineering mode by Menu > Mode > Application Mode (Figure 5).
i. LED ON/OFF (Figure 6)
Click ‘LED2’ and ‘LED3’ to toggle the LEDs on or off on remote users’
SGW2828-EVK. Messages will show up in the message boxes of both local and
remote users’ PC Tool.
ii. Text (Figure 7)
Input messages in the message box and click ‘Send’. Messages will show up in
the message boxes of both local and remote users’ PC Tool.
d. Engineering Mode
Engineering mode is designed for AT command testing, for example:
i. Get firmware version
ii. Send text thru AT command
The PC Tool is set to User Application mode by default, and Engineering mode
can be accessed by Menu > Mode > Engineering Mode (Figure 8).
Remarks: Please refer to AT Command Application Note for complete AT command
list.
i. Get Firmware Version (Figure 9)
Type command AT+VERSION=? In the command input box and click ‘Send’. The
firmware name and version number will be shown in message box.
ii. Send Text Thru AT Command
Type AT+RF_SEND=1,0,4 in command input box and type text (e.g. abcd) in the
message input box and click ‘Send’ (Figure 11). Tick the Hex box if the
message is in Hex format data.
Remarks: Please refer to AT Command Application Note for complete AT command
list.
On the local PC Tool, the sent message will be shown in Hex format in the message box on the left, while details of data received and sent will be shown in the message box to the right (Figure 11).
On the remote PC Tool, the received message will be shown in the message box to the left, with details in the message box to the right (Figure 12). Hexidecimal values will only be shown in the message box to the right.
e. Firmware Upgrade
When available, firmware updates can be made at Menu > Others > Firmware
Upgrade (Figure 13).
Click ‘FileDir’ to select the firmware file, then click ‘Upload’ to start the
upgrade. A progress bar will appear – please stay on the page until the
upgrade procedure is complete (Figure 14).
After firmware upgrade is completed, click the Arrow to return to the main
page. Then check the firmware version in Engineering Mode by command
AT+VERSION=? to ensure upgrade is completed.
Related Documents and Useful Links
- PC Software Download: https://www.sgwireless.com/uploads/prod-uct/files/SGW2828%20PC%20Tools%20V1.5.1.zip
- SG Wireless SGW2828-01A LoRa Module: https://sgwireless.com/product/SGW2828.
- SG Wireless SGW2828 LoRa Module AT Command User Manual: https://www.sgwireless.com/uploads/product/files/USGA5.03V2.0%20SGW2828%20LoRa%20Module%20AT%20Command%20User%20Manual.pdf
- Semtech SX1276 Documentation: https://www.semtech.com/products/wireless-rf/lora-transceivers/sx1276.
- Segger J-Link Download: https://www.segger.com/downloads/jlink/.
Revision History
Revised | Version | Description |
---|---|---|
13-Oct-2020 | 1 | Initial document release |
21-Dec-2022 | 1.1 | Update on PC Tool version |
28-Apr-2023 | 1.2 | Add firmware upgrade feature |
Contact us at cs@sgwireless.com for any queries,
or find us at any channel below
Website: https://sgwireless.com/
LinkedIn: https://www.linkedin.com/company/sgwireless/
Facebook: https://www.facebook.com/sgwirelessIoT
Twitter: @sgwirelessIoT
Information in this document is provided solely to enable authorized users or
licensees of SG Wireless products. Do not make printed orelectronic copies of
this document, or parts of it, without written authority from SG Wireless. SG
Wireless reserves the right to make changes to products and information herein
without further notice. SG Wireless makes no warranty, representation or
guarantee regarding the suitability of its products for any particular
purpose, nor does SG Wireless assume any liability arising out of the
application of any product and specifically disclaims any and all liability,
including without limitation consequential or incidental damages. SG Wireless
does not convey any license under its patent rights nor the rights of others.
SG Wireless products May not be used in life critical equipment, systems or
applications where failure of such equipment, system or application would
cause bodily injury or death. SG Wireless sells products pursuant to standard
Terms and Conditions of Sale which may be found at
https://www.sgwireless.com/page/terms. SG Wireless may refer to other SG
Wireless documents or third-party products in this document and users are
requested to contact SG Wireless or those third parties for appropriate
documentation. SG Wireless™ and the SG and SG Wireless logos are trademarks
and service marks of SG Wireless Limited. All other product or service names
are the property of their respective owners.
© 2023 SG Wireless Limited. All rights reserved.
SG Wireless™ Confidential
References
- Commercial IoT - SG Wireless
- SGW2828-01A LoRa Module - SG Wireless
- LoRa Connect Transceiver, SX1276, 137MHz to 1020MHz | Semtech
- Terms and Conditions of Sale - SG Wireless
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>