NICOR DQR2-10-120-3K-WH-BF 2-inch. Square LED Down Light Instruction Manual
- June 4, 2024
- NICOR
Table of Contents
LED Recessed Downlight
Installation instructions for 2″ Retrofit LED
DQR2-10-120-3K-WH-BF 2-inch. Square LED Down Light
WARNING: These products may represent a possible shock or fire hazard if
improperly installed or attached in any way. Products should be installed in
accordance with these instructions, current electrical codes and/or the
current National Electric code (NEC).
CAUTION — To reduce risk of fire, electric shock or injury to persons:
- Make sure that the electrical power to the fixture is disconnected prior to any installation or retrofit.
- This light is suitable for damp, wet locations.
- Use with 2″ recessed cans (recessed housing) only. Do not attempt to alter for other sizes or purposes.
- For best dimming results, use standard incandescent wall dimmers in a branch circuit that is supplied with 120V AC power. Check the dimmer manufacturer’s specifications to confirm whether minimum loads apply.
WARNING : Risk of fire or electric shock. Install these kits only in
luminaires that have the construction features and dimensions shown in the
illustrations herein ( 2″recessed housings) Confirm this before installation
by checking the interior of the housing for a manufacturer’s part number and
specifications; or
measuring the diameter of the housing. The recessed housing must have a
minimum diameter (opening) of 31/4″; maximum diameter of 31/2″; minimum inside
clearance of 33/4″. See Figure 1. Do not make or alter any open holes in a
wiring enclosure or in any electrical components installation!
WARNING: Risk of fire or electric shock. Kit installation requires
knowledge of recessed lighting electrical systems. If not qualified, do not
attempt installation. Contact a qualified electrician. measured inside
Do not use these products in luminaires located where elevated ambient
temperatures exist. during kit luminaires
WARNING : Risk of fire or electric shock. The electrical rating of this
product is 120V Ac. The installer must determine whether the power supply is
120V AC at the luminaire before installation. (120V/277V Ac 50-60Hz is
available if 120V/277V is indicated on the caution label)
WARNING: Risk of fire or electric shock. Luminaire’s wiring, ballast(s),
or other electrical parts may be damaged when drilling for the installation of
reflector kit hardware. If drilling is required in any installation, check for
enclosed wiring and components and be careful to protect them from any harm.
To prevent wiring damage or abrasion, do not expose wiring to the edges of
sheet metal or other sharp objects. THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
RETROFIT INSTALLATION
- Always make sure the power to fixtures is disconnected before beginning the removal of existing trim or retrofit installation.
- Remove the existing lamp, trim, and socket plate from the housing.
- Disconnect the orange-colored connector on the fixture (FIG 2).
- Assemble the E26 socket adapter to the existing socket coming down from the housing.
- Connect the orange-colored connector on the fixture.
- Push the fixture gently to the ceiling until seated (FIG 3).