PHILIPS WL140V LED34S CoreLine Wall Mounted Light Instructions

May 15, 2024
Philips

PHILIPS WL140V LED34S CoreLine Wall Mounted Light

Specifications

  • Product: CoreLine Wallmounted WL140V
    LED34S/830 PSED ELB3 WH

  • Power: 38.5 W

  • Dimensions: D390 mm

  • Luminous Flux: 3,350 lm

  • Color Temperature: 3000 K

  • Emergency Lighting: DALI, IP65, ELB3h/EL-DC

Product Usage Instructions

Lighting

The CoreLine Wallmounted WL140V LED34S/830 PSED ELB3 WH is a high-performance wall-mounted luminaire suitable for various indoor and outdoor lighting applications. Follow these steps for proper usage:

Installation

  1. Ensure the power supply is switched off before installation.
  2. Mount the luminaire securely on the wall using appropriate fixtures.
  3. Connect the luminaire to the power source as per the provided wiring diagram.

Operation

To operate the luminaire:

  • Switch on the power supply.
  • Use the dimmable feature if desired for adjusting the light intensity.

Maintenance

Regularly clean the luminaire and check for any signs of damage. Replace the light source when necessary following the provided instructions.

FAQ

Is the CoreLine Wallmounted luminaire suitable for outdoor use?

Yes, the luminaire is IP65 rated, making it dust and jetproof, suitable for outdoor applications.

Can the light intensity be adjusted?

Yes, the luminaire is dimmable, allowing users to adjust the light intensity as needed.

CoreLine Wall- mounted

WL140V LED34S/830 PSED ELB3 WH
CoreLine Wall-mounted, 38.5 W, D390 mm, 3350 lm, 3000 K, DALI, IP65, ELB3h/EL- DC
CoreLine wall-mounted solutions deliver on the CoreLine promise of innovative, easy-to install and high quality luminaires. These circular-shaped, surface- mounted luminaires are suitable for both ceiling and wall installations and are easy to apply in circulation areas such as corridors, hallways and staircases. The modern, unobtrusive design, combined with a homogeneous light distribution, ensures this luminaire will blend into the architecture of most buildings. And thanks to the push-in connectors, installation of the CoreLine WL140V is fast and straightforward. This family includes Interact ready luminaires with integrated wireless communications, ready for use with Interact gateways, sensors and software.

Product data

Product data|
---|---
General Information| | | Glow-wire test| Temperature 850 °C, duration 30 s
Light source replaceable| No| | EU RoHS compliant| Yes
Number of gear units| 1 unit| | |
Driver included| Yes| | Light Technical|
Product family code| WL140V [Coreline Gen3 Wall Luminaire]| | Luminous Flux| 3,350 lm
Lighting Technology| LED| | Saturated Red (R9)| <50
Type of emergency lighting battery| Lithium| | Correlated Color Temperature (Nom)| 3000 K
Value ladder| Performance| | Luminous Efficacy (rated) (Nom)| 87 lm/W
CE mark| Yes| | Color rendering index (CRI)| >80
Warranty period| 5 years| | Flickering value (PstLM) Flickering value as| 1
Flammability mark| –| | per EN 61000-3-3|
ENEC mark| –| | Stroboscopic effect visibility measure (SVM)| 1.6
Beam angle of light source| 120 degree(s)| | Power consumption during Central DC| 3 W
---|---|---|---|---
Light source color| 830 warm white| | emergency mode|
Optic type| Symmetrical| | |
Luminaire light beam spread| 120° x 120°| | Approval and Application|
Unified glare rating CEN| 25| | Ingress protection code| IP65 [Dust penetration-protected, jet-
| | | | proof]
Operating and Electrical| | | Mech. impact protection code| IK10 [20 J vandal-resistant]
Input Voltage| 220-240 V| | Sustainability rating| –
Line Frequency| 50 or 60 Hz| | Protection class IEC| Safety class II
Initial CLO power consumption| – W| | Photobiological risk| Photobiological risk group 0 @200mm
Average CLO power consumption| – W| | | to EN62778
Inrush current| 18 A| | Photobiological risk specification| 0.2 m
Inrush time| 0.025 ms| | |
Power Consumption| 38.5 W| | Initial Performance (IEC Compliant)|
Power Factor (Fraction)| 0.9| | Luminous flux tolerance| +/-10%
Connection| Push-in connector 6-pole| | Initial chromaticity| (0.4338,0.4030) SDCM <3
Cable| –| | Power consumption tolerance| +/-10%
Number of products on MCB of 16 A type B| 34| | |
| | | Over Time Performance (IEC Compliant)|
Temperature| | | Control gear failure rate at median useful life| 5 %
Ambient temperature range| 0 to +25 °C| | 50000 h|
| | | |
| | | Lumen maintenance at median useful **life*| 80
Controls and Dimming| | | 50000 h|
| | | |
Dimmable| Yes| | |
Driver/power unit/transformer| Power supply unit with DALI interface,| | Application Conditions|
| DC compatible for central emergency| |
Performance ambient temperature Tq| 25 °C
| lighting (integrated)| |
Maximum dim level| 1%
Control interface| DALI| | Suitable for random switching| No
Constant light output| No| | |
| | |
Product Data|
Mechanical and Housing| | | Order product name| WL140V LED34S/830 PSED ELB3 WH
Housing Material| Polycarbonate| | Full product name| WL140V LED34S/830 PSED ELB3 WH
Reflector material| Polycarbonate| | Full product code| 871869997872300
Optic material| Polycarbonate| | Order code| 910505101558
Optical cover material| Polycarbonate| | Material Nr. (12NC)| 910505101558
Fixation material| –| | Numerator Quantity Per Pack| 1
Housing Color| White| | EAN/UPC – Product/Case| 8718699978723
Optical cover finish| Opal| | Numerator Packs per outer box| 1
Overall height| 85 mm| | EAN/UPC – Case| 8718699978723
Overall diameter| 390 mm| | |
| | | |
Emergency Operation| | | |
Emergency flux**| 350 lm| | |

Dimensional drawing

PHILIPS-WL140V-LED34S-CoreLine-Wall-MountedLight-FIG-1

© 2024 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.

www.lighting.philips.com
2024, March 11 – data subject to change