  • Vacuum Generator Model: CM85
  • Vacuum Port: M5 connector, compatible with 4/6mm air pipe
  • Voltage: DC/24V
  • Features: Vacuum switch control valve (VAC), vacuum breaking control valve (BLOW)
  • Adjustment: Slotted screw for vacuum break size adjustment

Product Usage Instructions

  1. Installation:
    Connect the V port to an external M5 connector using a 4/6mm air pipe. Ensure to install an air filter core between the V port and the suction cup to prevent dust and debris from entering the vacuum system.

  2. Power Connection:
    Connect the vacuum switch control valve (VAC) and vacuum breaking control valve (BLOW) to a DC/24V power source.

  3. Vacuum Adjustment:
    Use the slotted screw to adjust the size of the vacuum break. Clockwise rotation increases the vacuum size, while counterclockwise rotation decreases it.

  4. Digital Display Pressure Switch Wiring:
    Follow the wiring method for the pressure switch: Brown for power input DC/24V, Blank for NPN output, White for analog signal output 1-5V, Blue for OV.

  5. Output Circuit Wiring:
    Refer to the provided output circuit wiring diagram for correct wiring configuration.

Frequently Asked Questions (FAQ)

  • Q: How often should the air filter core be replaced?
    A: It is recommended to replace the air filter core regularly, typically every 3-6 months depending on usage and environmental conditions.

  • Q: Can the vacuum generator be used with a different voltage other than DC/24V?
    A: No, the vacuum generator is designed to operate specifically with DC/24V voltage input.

CM85 vacuum generator operating instructions

  1. Positive pressure of 0.5Mpa, ±0.05Mpa is applied to both sides of the P at the same time, and there are 1 minute 8mm-10mm trachea on both sides.
  2. V is the vacuum port, which is connected to an external M5 connector and a 4/6mm air pipe. In order to ensure a longer service life, an air filter core needs to be connected between the V port and the suction cup to prevent dust and debris from being sucked into the vacuum and affecting the service life of the vacuum valve.
  3. VAC is a vacuum switch control valve, DC/24V.
  4. BLOW is a vacuum breaking control valve, DC/24V.
  5. The slotted screw is used to adjust the size of the vacuum break. Clockwise is to adjust the size of the vacuum, and counterclockwise is to adjust the size of the vacuum.
  6. Digital display pressure switch wiring method:
    • Brown is the power input DC/24V
    • Blank is NPN output
    • White is an analog signal output 1-5V
    • Blue is OV

Digital pressure switch wiring diagram

duet3d-CM85-Vacuum-Generator- \(1\)

Digital display switch parameter setting operating instructions

duet3d-CM85-Vacuum-Generator- \(2\)

Digital display switch parameter setting operating instructions

duet3d-CM85-Vacuum-Generator- \(3\) duet3d-CM85
-Vacuum-Generator- \(4\) duet3d-CM85-Vacuum-Generator-
\(5\) duet3d-CM85-Vacuum-Generator- \(6\)

Output circuit wiring diagram

duet3d-CM85-Vacuum-Generator- \(7\)

duet3d-CM85-Vacuum-Generator- \(8\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals