WALL -MOUNTED ROOM HEATER
OWNERS MANUAL
SMAX_030424 Wall Mounted Room Heater
Economical
Ultra-safe
Effective
Healthy| Simple
Stylish
Silent
---|---
https://envi-s.com/manuals?r=qr
AMERICAN
OWNED AND BUILT United States Patent: 8,477,176
IMPORTANT CUSTOMER INFORMATION:
THIS HEATER WILL NOT TURN ON UNLESS MOUNTED ON A WALL
(Please read more about this unique safety feature on the page 4)
THANK YOU FOR CHOOSING THE ENVI HEATER
Please take a few moments to thoroughly read the instructions and familiarize
yourself with all the operational aspects, installation and care of your new
Envi Heater. For your own records, please attach a copy of your sales receipt
to this manual. Also, write the store name/location, date, and serial number
in the warranty section on the page 11.
Models Covered by This Manual
Model Type| 500 W / 120 V Models| 500 W / 220 V Models| 1000 W / 120 V Models|
1000 W / 220 V Models
---|---|---|---|---
Plug-In with Thermostat| LE5012P| –| EM1012P| –
Hardwired with Thermostat| LE5012D| LE5022D| EM1012D| EM1022D
Hardwired No Thermostat| LE5012N| LE5022N| EM1012N| EM1022N
Smart Plugin| SE5012P| –| SM1012P| –
Smart Hardwired| SE5012D| SE5022D| SM1012D| SM1022D
Missing parts?
Have questions or need help?
(PLEASE DO NOT RETURN TO RETAIL STORE BEFORE YOU CALL THE ENVI HELP DESK)
We are here to help you with any questions you might have. Before you call for
help though, please read this manual as it contains instructions to help you
to install, operate and maintain your heater properly. If you still need help
please call the Envi Help desk in
the USA/Canada Toll Free @ (800) 807-0107 or if calling from outside the USA
call +1 (281) 516-1577.
Features & Benefits
- American owned & built with 3 year warranty (USA )
- ISO 9001 Quality Certification.
- Patented, efficient “Stack Convection” technology
- Adjustable temperature control with simple operation.
- Wall-Sens™ technology, safety cut off feature.
- Internal safety locking screw feature locks heater to wall using provided allen key tool.
- Convenient cordset storage inside the heater.
- Turn down the central heat thermostat and use envi heaters where needed – to save on heating bills.
- Environmentally friendly – low power consumption.
- Eliminates hot and cold spots where central heat is ineffective.
- Ultra safe – cool to the touch (90° F/32° C) can remain in use, unattended 24/7.
- Healthy – won’t blow dust and allergens around the room or dry out the air.
- Totally silent fanless technology.
- Auto-dimming power light for dark bedrooms.
- Easy installation – no drill required for mounting to wall.
- Slim – space saving design, only 3.1in (7.9cm) thin.
- Long life – no moving parts, crack resistance surface
- 120 volt and 220 volt hardwired models available.
Important Instructions
HEATER WILL NOT OPERATE UNLESS WALL MOUNTED
When using electrical appliances, basic precautions should always be followed
to reduce the risk of fire, electric shock, and injury to persons, including
the following:
-
Read all instructions before installing or using this heater.
-
Extreme caution is necessary when any heater is used by or near children or invalids, or when the heater is left operating and unattended.
-
Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.
-
For plug-in heaters, to disconnect, push power button to turn heater off (the power indicator light will turn off), then remove plug from outlet. Pull firmly on the plug, do not unplug by pulling on the cord.
-
Connect to properly grounded outlets only.
-
For hardwired heaters, to disconnect, turn controls to off, and turn off power to heater circuit at main disconnect panel (or operate internal disconnect switch if provided).
-
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
-
To prevent a possible fire, do not block air intakes or exhaust in any manner.
-
A heater has hot or arcing parts inside. Do not use in areas where gasoline, paint, explosive and/or flammable liquids are used or stored.
Keep unit away from heated surfaces and open flames. -
Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
-
Use only for the intended household or office uses as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
The use of non-recommended attachments sold by unauthorized dealers may cause hazards. -
Do not use outdoors.
-
This heater is intended for use as a WALL MOUNTED heater only.
Failure to properly secure the heater to a flat, level and vertical wall may result in heater malfunction and/or property damage. -
This heater will not operate (will not power on) unless it is attached to a wall using the supplied wall mounting clips which engage the internal “wall-sens” safety switch.
-
DO NOT attempt to repair or replace any electrical or mechanical part on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. Qualified personnel should perform all servicing only.
Save these instructions
Installation Instructions
WHAT IS IN THE BOX
- Envi Wall Mounted Heater
- Owners Manual
- 2 x Mounting Clips
- 2 x Drywall Anchors / 2 x Masonry Anchors
- 2 x #8 Mounting Screws
- Locking Bar Screw and 3/32″ Hex Allen Key Tool
- Knockout Hole Grommet (hardwired models only)
- Wall Anchor Marking Template. Template holes are marked on the unfolded edges of the packaging insert frame.
New heater smell is normal and will disipate in a couple of hours.
Operating Instructions
HOW IT WORKS
The Envi Heater is designed with innovative “Stack Convection Technology”
that effectively heats a room with minimal energy. The Envi’s inner chamber
simulates “stacks” of varying height, which boost airflow through the heater to
achieve maximum efficiency. The end result is enhanced airflow at safe air
temperatures, all without the use of a fan. The Envi heater will provide
consistent, comfortable, silent heat without drying out the air or leaving
cold spots in the room.
OVERHEAT SAFETY FEATURE
This heater is equipped with an overheat safety feature. When the heater’s
internal components reach a certain temperature that could cause overheating
and a possible fire, the heater will automatically shut off . To reset the
heater, unplug the heater power cord from the electrical outlet for 10
minutes. After 10 minutes, plug the heater into the electrical outlet and turn
on using the heater’s on/off switch located on the front of the unit. WALL MOUNTING
Remove the heater, mounting kit, and packaging insert frame from the box.
Keep the packaging materials for future use.
- Unwrap and flatten the sides of the packaging insert frame (mounting template) and stand the template on the floor. The sides of the template have pre-punched holes to mark the heater mounting height for either 6” or 8” (15 or 20cm) from the bottom of the heater to the floor. Choose either mounting height, and mark two hole locations on the wall. (see Fig. 1). The top two hole locations are for the mounting clips.
- Screw the anchors (Fig. 2) into wall at the marked locations. The distance from the top screws to the floor should be approx. 19″ to 21″ (48cm to 53cm). If a stud is in the way, do not use the drywall anchor supplied, just drive supplied mounting screw directly into the stud. For masonry walls, use the masonry wall anchors provided and drill a 4.5mm (3/16inch) hole using a masonry drill bit (not supplied). Important Mounting Tips
1) The right hand side of the heater must be securely and firmly pushed down on the clip to engage the “wall-sens” power cut-off switch inside the heater. Align this side of the heater first, to ensure the switch is activated. For uneven walls, a thin washer can be used to widen the gap behind this clip to help seat the heater properly.
- The heater can be mounted at other heights besides 6″ or 8″. To do this, measure where you want the bottom of the heater to be on the wall and then measure up an additional 13″ (33cm) and mark your screw locations.
-
Screw the two mounting clips (with arrow pointing upward) into the top two anchor locations and secure firmly to the wall anchors using the provided screws. (see Fig. 3). DO NOT overtighten. There should be a gap behind the mounting clip to hang the heater.
HEATER WON’T TURN ON IF NOT WALL MOUNTED! -
Note: make sure you pre-install the locking bar screw before you mount the heater. (See Fig. 5 below). Install heater on mounting clips (align right side first) and make sure to press down firmly on the heater to ensure a secure fit. You will hear it “snap” into place. (Figure 4 on the left)
For additional information visit www.eheat.com
Installing Locking Bar for Permanent Attachment
- Envi Wall-Mounted Heaters have an additional method to permanently attach the heater to the wall. A locking bar mechanism is built in the heater, which is engaged by screwing an external locking screw into the bottom of the heater vent. The locking screw and Hex/Allen Key are both provided in the mounting kit. Installing the Locking Bar Screw (Fig. 5) BEFORE YOU MOUNT THE HEATER TO THE WALL. Take the locking bar screw out of the mounting kit and while the heater is laying flat, use the Hex/Allen key provided to pre-install the screw in the hole at the left hand side of the bottom vent (Fig 5). Twist the locking screw in about 3/8 of an inch but make sure you do not screw it in too far as it will obstruct the mounting holes at the back of the heater and prevent secure mounting.
- Mount the Heater. Attach the heater to the wall by following the rest of the mounting instructions on previous page.
- Tighten Locking Screw (Fig 5) Follow the rest of the mounting instructions to ensure the heater is properly seated on the mounting clips and then tighten the locking screw to fix the heater to the wall.
DO NOT USE A POWER TOOL! DO NOT OVERTIGHTEN, just turn the screw until the locking bar presses gently up against the left hand mounting clip inside the heater.
Congratulations, you have now permanently mounted your Envi Heater!
Hardwiring Instructions
The Envi Heater is available in some regions as a hardwired model and can be
hardwired direct to a main supply, branch circuit or it can be hardwired to a
line voltage external thermostat of the same voltage as the heater (eg. 120v)
or to an external switch or timer. Consult the instructions for each of these
control devices for specific wiring instructions. The Envi Heater can also be
wired as multiple heaters on the same circuit or controller. Please consult a
certified electrician and ensure that all electrical work is done in accordance
with applicable electrical and building codes.
CAUTION
To prevent short circuits and electrical shocks turn the power off at the main
electrical panel before attempting the hardwiring installation or any repairs.
If the internal power cable (cordset) is damaged it must be replaced by the
manufacturer.
NOTE
Hardwired heaters must be connected to the correct voltage circuit according
to its model designation, ie. (LE5012, EM1012 etc = 120 volts; LE5022, EM1022
etc = 220 volts). Disconnect the power supply before making wiring connections
to prevent electrical shock and equipment damage.
WIRING SCHEMATIC
NOTE: The following wiring schematic is for a single Envi Heater
installation to the applicable ac main supply circuit and assumes that the
there are no external controls being wired to the heater.
-
Determine the best wall mounting location of the Envi Heater in a room. If the proper electrical wiring and wall box already exists at a suitable height on the wall, then choose a suitable knock-out hole on the back of the heater (5 holes to choose from) and position the heater on the wall so that the knockout hole lines up with the electrical wall box. Refer to Fig. 8 for more details.
If new heater circuit wiring and wall box is to be installed, then it is best to mount the heater first and then determine the corresponding location on the wall for the new electrical wiring wall box. When installing a new wall box, ensure it is at a proper location on the wall to allow the heater to remain at 6” to 8” (15cm to 20cm) or so above the finished floor level.
Turn the power OFF at the main electrical panel to the heater circuit. Run the electrical wiring and secure it properly to the electrical box per applicable electrical and building codes.
(NOTE: Although the Envi Heater has a low amperage draw, the electrical code requires a minimum supply wire gauge to be used usually 12g, so make sure you check first.) -
Mount the Envi Heater using the two mounting clips per the “Wall Mounting Instructions” (see page 4) contained herein to ensure that the heater is at the proper location on the wall and that the knockout hole is aligned with the supply wiring.
-
Remove the Envi Heater from the wall to prep for the hardwiring steps. Pull the cordset through the knockout hole using pliers and install the supplied protection grommet. Strip wires to expose 5/8″ of copper on all 3 of the cordset wires (see Fig. 8).
Install the bottom door supplied in mounting kit. Rotate and lay the heater on the ground so that the bottom right corner is facing up and the back of the heater is facing the wall (see Fig. 9). Connect the heater wires L1 (live) , L2 (neutral) and G (ground) to the corresponding supply wires in the wall box per the wiring schematic above. -
Push as much of the connected wiring/nuts deep inside the wall box opening until the heater is sitting flush with no wiring trapped between the heater and the wall. Carefully lift the heater back onto the wall mounting clips that were installed earlier. Re-mount the Envi Heater to the wall, ensuring all three mounting screws are used and the Locking screw is tightened.Rotate heater and lay on its left side front facing out to prepare for joining the wires
-
Turn the power ON at the main electrical panel to the heater circuit. Check that there are no obvious problems with the hardwiring to the heater (such as crackling noises, sparks or smoke) and if everything is okay, turn on the power to the heater by pressing the on/off button. If the wiring has been performed correctly, then the power indicator light will glow red.
ONLY CONNECT 120V SUPPLY TO 120V ENVI HEATERS.
IF YOU’RE NOT SURE IF YOU HAVE 120V OR 220V AVAILABLE DO NOT PROCEED!
220V (4 WIRE) BASIC HARDWIRING GUIDE FOR USA HARDWIRED MODELS
Please note that this is a very basic and “rough guide” and may not apply
to every situation. The terms “110 volt” and “220 volt” are synonymous with
120 volt and 240 volt, respectively. When a customer encounters existing 220
volt four wire supply wiring, there could be more than one way these wires
might be configured, however, the usual 220 volt arrangement is as follows.
Typically 220 volt, 4 wire supply wiring has a black wire and a red wire, each
of which are 110 volt live legs. Sometimes these are two black wires. There
will sometimes be a white wire which is usually a neutral wire, used to power
110 volt devices (do not assume this though, because it could be a thermostat
leg or another ground wire).
Lastly, there should be a green or bare copper wire is usually the ground
wire. Be very careful and never assume!
220 VOLT SUPPLY WIRING | (CONNECT TO) | ENVI HEATER CORDSET WIRES |
---|---|---|
Black Wire (Live 110 volts) | Black Wire | |
Red or 2nd Black Wire (Live 110 volts) | White Wire | |
Green or bare copper wire | Green Wire | |
White Wire (Not needed, cap this off) |
Did you know? 220 volt supply (known as 240 volts in the USA) comes into a home from an outside transformer on two separate wires (legs) which have opposite phases or polarity. The electrical current alternates on one leg from +110 volts to 0 volts and alternates from -110 volts to 0 volts on the other leg (wire). The overall difference between the two legs when connected is 220 volts. So, now you know where 220/240 volts comes from!
Economical. Safe. Simple.
WALL-SENS™ SAFETY FEATURE
In addition to the overheat safety cut-off, the Envi Heater is equipped with an
additional layer of safety to give you greater peace of mind. Wall-Sens™
technology means that in the event that the Envi heater is ever removed from
the wall, power will be immediately cut to the heater. This of course means
that the heater will not work if it is simply removed from its packaging and
plugged into a wall outlet. It must be mounted properly (safely) and then
plugged in (or hardwired) in order for it to be begin to heat.
ELECTRICAL GROUNDING
Plug-in models of the Envi Heater are for use on standard electrical
circuits (eg. 120v for USA/Canada). The cord has a three-blade grounding plug.
An adapter can be obtained at most hardware or electrical stores for
connecting three-blade grounding type plugs to two-slot receptacles. The
grounding lug extending from the adapter must be connected to a permanent
ground such as a properly grounded outlet box. The adapter should not be used
if a three-slot grounded receptacle is available.
DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG.
Envi & Envi Max Operating Instructions
-
Install the heater on a firm, level wall and plug the power cord into a grounded power outlet (or hardwire if applicable). The heater will only operate when it is properly attached to the mounting clips. Be sure to mount in upright position with the thermostat dial and power button at the top of the heater.
-
Once the heater is connected, press the front on/off power button and the POWER INDICATION LIGHT will glow red. (Fig. 10)
-
The Envi Heater is equipped with a built-in thermostat which is adjusted with a dial at the top of the heater. Adjust the room temperature by turning the thermostat dial CLOCKWISE to increase the room temperature. If the area becomes too warm, rotate thermostat dial COUNTER-CLOCKWISE until the temperature is more comfortable. (Fig. 10)
-
Once you have chosen the desired setting, the thermostat will maintain a constant temperature.
NOTE: Models with no thermostat have no temperature control and will stay on until the heater is powered off by either an external switch or external thermostat.
NOTE: For models hardwired to an external thermostat, the built-in heater thermostat should be left on the hottest setting. -
The heater is equipped with an innovative auto dimming feature that dims the power light in a darkened room to help light sleepers. The heater automatically detects when the light level in a room drops and then dims the power light.
-
The plug-in cordset of the Envi Heater can be stored inside the bottom access door. Determine how much cordset you require to extend out of the heater. Remove the heater from the wall, and remove the bottom access door. Carefully push the excess cordset inside the heater (use a wooden ruler or similar) and replace the bottom access door. Re-install the heater to the wall and plug-in the cordset to continue using your heater. For more information please visit the installation web page of www.eheat.com
Smart Envi & Smart EnviMAX Quick Start Guide
- Install your heater, plug it in and turn it on.
- Download and install the Envi Smart Heater app on your phone.
| |
---|---|---
https://envi-s.com/android?r=qr
|
-
Follow the prompts to create an account.
Input the security code from the verification email. -
From the app home screen click the plus sign to add a heater.
-
Follow the prompts until you see “Ready to connect”, You can now connect your heater to your WiFI.
-
Next, follow the prompts to connect your heater to the Internet using your wifi until you see “Connection Successful”.
-
Congratulations, your heater is paired with your phone and connected to the Internet, to be operated by you, anywhere in the world!
Smart Envi & Smart EnviMAX Operating Instructions
Timer
Timer automatically shuts off the heater after the desired amount of time.
Press to set timer
Press to start timer
Press to change time in 30 minute increments
Schedule mode
Note: heater must be left powered on in order for scheduling to work. The
schedule does not turn the heater on.
Use the built-in scheduler to control your room temperature.
Set it to save power while you’re away and turn up the heat to have your room
nice and cozy by the time you get home.
To activate the schedule mode press and hold for 3 seconds, heater will now
follow the programmed schedule.
Schedule can be programmed in the main menu, see main menu options below.
*The Envi Smart App allows you to easily create and switch between more flexible schedules. If you pair your Smart Envi with your phone, the more limited on-board schedule is disabled and schedules can be created on your phone. Menu
The menu gives you access to less used options and controls.
When in the menu use to navigate through options and change settings, use to
advance and to save setting changes and use to go back and to cancel setting
changes.
Menu items are as follows:
Display: Change display settings.
Auto brightness allows the display to change brightness automatically based on
room illumination level. You can enable or disable this feature.
Change brightness allows you to select the desired display brightness. This
setting only applies when auto brightness is disabled.
Timeout turns the display off automatically after 3 minutes of inactivity. You
can enable or disable this feature.
Night Light: Change nightlight settings
On/off: turn night light on or off.
Auto brightness allows the night light to change brightness automatically
based on room illumination level. You can enable or disable this feature.
Change brightness allows you to select the desired night light brightness.
This setting only applies when auto brightness is disabled.
Timer: Change timer settings
Timer on/off: turn timer on or off.
Set Duration: set how long timer should run.
Set Temperature: set the temperature you want the heater to maintain during
the timer operation.
Network: Network settings and information
Change network allows you to switch your heater to a new wifi network
(requires phone and app).
Device IP address: allows you to see your heater’s IP address if it is
connected to a network.
Wi-Fi signal: Displays the strength of Wi-Fi signal from the router.
Freeze Protect: Protects your room from freezing temperatures by
automatically turning on the heater if room temperature falls below 40° F (5°
C)
Enable or disable this feature.
Child Lock: Protect your heater from unintended changes by locking out the
buttons on the heater
Enable this feature
Child lock can also be enabled and disabled by holding down both the and for 3
seconds.
Device Settings: View and modify device settings
Firmware version displays current firmware version.
Factory Reset: Reset your heater to its original settings. This will unpair
your heater and remove it from your account.
Device Calibration: Your heater’s temperature sensor is calibrated at the
factory and should not require adjustment, however if you feel your heater is
reading too low or too high, you can use this setting to adjust the
calibration.
Temperature unit: Select between temperatures displayed in °F and °C.
About: Displays your device ID. This is the default name of your heater in the
app and what you will see when the app detects a heater when pairing.
Power light: Change settings for the red power light
Auto brightness allows the display to change brightness automatically based
on room illumination level. You can enable or disable this feature.
Change brightness allows you to select the desired display brightness. This
setting only applies when auto brightness is disabled.
Set Schedule: Allows you to create and turn on/off the on-board schedule
On/Off Schedule: activate or deactivate schedule mode.
Set 5-1-1 Schedule: Creates the schedule. When creating the schedule, you
cycle between settings using and and then press to edit that setting.
Setting a schedule:
The best way to program your heater to follow a schedule is using our free
smart-phone app. However, if you do not wish to use the app, you can program a
schedule directly on the heater.
To program a schedule:
Select “Program 5-1-1” schedule in the menu.
Screen will show “M-F” and “wake”, The time will be flashing, use the (up
button) and (down button) to select the time you want to apply the wake
setting during the work week, click the (power button) to set the time.
Now the temperature will flash, use the (up button) and (down button) to select
the temperature you want to set at the wake time during the work week, click
the (power button) to set this temperature.
Repeat this process for the “leave”, “return”, and “sleep” times for M-F, and
then selecting times and temperatures for Saturday and then Sunday. When this
is complete press (power button) to save the schedule.
At any time while setting the schedule you can use the (timer button) to go
back to the previous step.
Set Time/Day: Set the internal clock on your heater, this is necessary if
schedule is to operate properly.
Set time: set the current time.
Set day: Set the current day of the week.
Set Daylight savings: Turn daylight savings time on/off.
Set Timezone: Specify which time zone your heater is operating in.
The heater is equipped with an innovative auto dimming feature that dims the
power light in a darkened room to help light sleepers. The heater
automatically detects when the light level in a room drops and then dims the
power light.
The plug-in cordset of the Envi heater can be stored inside the bottom access
door. Determine how much cordset you require to extend out of the heater.
Remove the heater from the wall, and remove the bottom access door. Carefully
push the excess cordset inside the heater (use a wooden ruler or similar) and
replace the bottom access door. Re-install the heater to the wall and plug-in
the cordset to continue using your heater. For more information please visit
the installation web page of www.eheat.com
To get the most out of your Envi Heater, please follow these helpful
hints:
OPTIMAL OPERATING CONDITIONS
- For optimal performance in a room, close all doors for first time use. You may have to leave your 500 watt heater on for several hours to enable the room to reach equilibrium temperature while the heat builds gradually. This will allow the room to reach equilibrium temperature while the heat is gradually building up.
- For optimal performance, mount the heater on an interior wall with the bottom of the heater 6” to 8” (15 to 20cm) from the floor. For smaller rooms this can be increased with little detriment, however try to keep the bottom of the heater a maximum of 18” (46cm) from the floor.
- The 500 watt Envi heaters are designed to heat rooms up to 150 ft² in size (14m²) and the 1000 watt heaters are designed to heat up to 350 ft² (28m²). Of course, this will vary depending on a number of factors, including outdoor temperature, room insulation, room draftiness, room objects, etc.
- To save energy and to reduce your heating bills, place the heater in a room or area that needs extra heat instead of raising the thermostat on your central heating system. This heater will function very well as both a sole source of heat or as an additional heating source that can easily maintain the temperature in most rooms and attached bathrooms if the correct number of Envi heaters are installed. There is no need to increase the heat in the entire house when you only need comfort in the room in which you are currently located.
- We highly recommend that our customers weatherize their homes or offices to further reduce their heating bills. Simple tasks such as replacing weather stripping around doors and windows, caulking doors and window seams, sealing attics and basements properly, and adding more insulation to your walls and ceiling will help further to reduce heating costs.
Care & Maintenance Instructions
CLEANING
-
Unplug the unit and let it cool completely.
-
To remove dust from the Envi heater, use a soft cloth on the exterior and use a compressed air can to blow dust through the top vent of the heater out the bottom.
-
To remove marks or stains from the heater, the front outer shell can be cleaned with a soft, damp cloth. You may use a mild detergent if necessary. After cleaning, dry the unit with a soft cloth.
CAUTION: Do not let liquid enter the heater. -
Do not use alcohol, acetone based cleaners, gasoline, abrasive powders, furniture polish, or abrasive or rough cloths or brushes to clean the front of the heater. This may cause damage or deterioration to the surface.
-
Do not immerse the heater in water.
-
Wait until the unit is completely dry before using again.
-
Some customers, over a long period of time may experience “dirty marks” on the wall above the heater. This can be caused by candles or dust being drawn into the heater and passed out the top. Over time this may leave dirty marks above the heater. The wall is not damaged and can easily be washed using appropriate cleaning products such as a magic eraser sponge.
STORAGE
Store the heater in a cool, dry location when not in use. However, the Envi
Heater is a slim, attractive wall mounted heater than can be left mounted on
the wall – all year round!
Troubleshooting
If the heater will not operate, please check the following before calling for help with technical questions:
- The number one trouble shooting tip is to check that the internal, electrical safety switch (Wall-Sens™ ) is being engaged. The heater WILL NOT OPERATE AT ALL if this switch is not engaged. This problem occurs when the right hand side of the heater is not pushed down far enough between the gap between the wall and the mounting clip. The mounting clip can become squished if it is screwed in too hard. Uneven walls can also cause the same mounting/wall switch problems.
- Check if the power cord is plugged into an electrical outlet and the heater is set to ON by confirming the light on the front of the panel is lit. If not, plug in the heater and press the on/off power switch.
- If the heater has been hardwired, consult an electrician to check that all connections have been made correctly. Make sure that you hardwire the correct voltage. Many people do not understand how to work with 220 volt wiring. Always triple check the voltage and the model heater that was purchased as this is a common mistake and can lead to heater malfunction and pose a serious safety risk.
- Check if there is electricity to the circuit by checking to make sure the breaker in the breaker box is in the “on” position.
Specifications & Certifications
PRODUCT SPECIFICATIONS
Power Rating: | 500 Watts (All Models) | 1000 Watts (All Models) |
---|---|---|
Volt & Amp Rating: | LE5012P/D/N Models = 4.17A @ 120V LE5022D/N Models = 2.27A | |
@ 220V SE5012P/D Models = 4.17A @ 120V SE5022D Model = 2.27A @ 220V |
EM1012P/D/N Models = 8.33A @ 120V EM1022D/N Models = 4.54A @ 220V SM1012P/D
Models = 8.33A @ 120V SM1022D Models = 4.54A @ 220V
Unit Size:| 19.3in W x 2.2in D x 22.2in H (49.0cm W x 5.6cm D x 56.4cm H)|
19.3in W x 3.1in D x 22.2in H (49.0cm W x 7.9cm D x 56.4cm H)
Net Weight:| 10 lbs (4.5 kg)| 12.3 lbs (5.6 kg)
Packaged Wt:| 12 lbs (5.5 kg)| 14.5 lbs (6.6 kg)
SAFETY LISTINGS
Conforms to UL Std: | UL 2021 |
---|---|
Cert. to CAN/CSA Std: | C22.2 No. 46 |
Conforms to IEC Std: | 60335-1 & 60335-2-30 |
Conforms to AS/NZS: | 60335.1 & 60335.2.30 |
COMMERCIAL FIRE SAFETY COMPLIANCE & CALIFORNIA TITLE 24 CERTIFICATION
The Envi Heater is in compliance with the requirements of The Life Safety
Code, NFPA 101 (2012), section 19.7.8. The Envi Heater is a fixed wall heater
(not portable) and operates with low surface temperatures and is thus suitable
for commercial use in Elderly Care, Childcare, corporate and government
facilities. The Envi Heater is also compliant for California Title 24 use in
Residential New Construction, Alterations and Additions. Contact the
manufacturer for more information if needed.
Warranty & Contact Info
THREE YEAR LIMITED WARRANTY
-
The manufacturer warrants the accompanying Envi Heater to be free of defects in material and workmanship for the applications specified in its operation instructions for a period of THREE (3) years from the date of original purchase in the United States of America and Canada. If the unit exhibits a defect in normal use, the manufacturer will, at its option, either repair or replace it, free of charge within a reasonable time after the unit is returned during the warranty period.
-
As a condition to any warranty service obligation, the consumer must present a copy of the original purchase invoice.
-
THESE WARRANTIES DO NOT APPLY FOR:
• Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in material or workmanship.
• Damage caused by improper installation or connection to incorrect supply voltage.
• Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the instructions.
• Damage to the finish of the case, or other appearance parts caused by wear.
• Damage caused by repairs or alterations of the unit by anyone other than those authorized by the Manufacturer.
• Freight and Insurance cost for the warranty service. -
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO A THREE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. THE MANUFACTURER DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL THE MANUFACTURERS LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.
-
Note: This warranty does not renew or extend with a replacement product. All warranties are from the date of the original product purchase.
-
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, salvaged, or refurbished products.
-
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
Manufacturer’s Contact Information
eheat, Inc.
Houston, TX, United States of America
support@eheat.com
Toll Free 800-807-0107
www.eheat.com
REGISTRATION DETAILS
Serial # (on back):|
---|---
Date Purchased:|
Location:|
Store Name:|
© 2024 eheat, Inc.
Toll Free 800-807-0107
www.eheat.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>