PHILIPS RC450B TrueLine recessed Instruction Manual
- May 15, 2024
- Philips
Table of Contents
RC450B TrueLine recessed
Instruction Manual TrueBlend
RC450B
RC450B TrueLine recessed
Product Family Code | P max [W] | |
---|---|---|
Flux | Basic | ELP/ELD/ELW |
RC4S5B RC455X RC453X RC453B | 20S | 13.8W – 22.5W |
28S / 36S / 40S / 42S | 17.8W – 42W | 23.8W – 48W |
34S / 43S / 48S / 50S | 21.5W – 49.5W | 27.5W – 55.5W |
Product Family Code | Rim Size | Max Weight |
--- | --- | --- |
Width [mm] | Length [mm] | Weight [kg] |
RC455B | 90-200 | 634-1970 |
RC455X | 100-200 | 634-1970 |
RC453B | 150-300 | 1195-1500 |
RC453X | 150-300 | 1195-1500 |
Wieland (W)
Functional Notice for Emergency Lighting
Automatic emergency time selection
After installation and power up the driver will detect the battery and start
the automatic detection process.
- During automatic detection, the indicator LED will light up with short green flashes.
- Between minimum 6 and maximum 30 seconds the TrustSight driver will set the battery type (number of cells) and will set the emergency output power accordingly.
After that, the system is defined and fully operational. The battery type definition has influence on the performance during the self-test and on the battery charge method. When the automatic battery detection process is disrupted, e.g. by switching off the permanent mains, the detection process is stopped and the TrustSight emergency driver will go into emergency mode with the lowest output power. At a next power up, the automatic detection process will start again.
Periodic testing
Periodic tests of emergency lighting luminaires must be performed according to
EN50172 clause 7.2.3 and 7.2.4.
Switch on in the emergency mode each month by simulation of a failure of the
supply to the normal lighting for a period sufficient to ensure that each lamp
is illuminated. Twice per year, each luminaire shall be tested for its full
rated duration (at least 3hrs).
For more information please consult the TrustSight Gen 3 Design in guide. The
latest version is available online.
LED indicator status
LED indicator (color/ flashing)| Error condition| Cause|
Solution
---|---|---|---
Green / no flashing| | System OK, battery fully charged
Off| | Mains oft EM mode, Rest mode, test in progress
Green /slow (0.25s on, 125s oft)| | System Old battery is charging
Green / fast (0.255 on, 0.25s off)| | System O/C recently tested (< 5 days,
Australia mode only)
Red /no flashing| Battery voltage too high or too low| No battery connected|
Connect battery
| Wrong or bad battery connected| Replace battery
Red /fast (0.25s on, 0.25s oft)| Output voltage too low or too high| Wrong LED
load connected| Connect right load and perform functional test
No load connected or output shorted| Wrong connection| Connect right load and
perform functional test
Red/slow (0.25s on, 1.25s oft)| Failed test due to battery| Battery end of
life Charger failure| Replace battery and perform duration test Replace driver
Red-green / fast
Fast flashing: (on-time = 0.25s, off-time = 0.25s) Slow flashing: (on-time =
0.25s, off-time = 1.25s)| | DALI device identification|
Green / short
on-time = 50ms, off-time = 0.95s)| | Battery detection|
Service
The battery should be replaced when it no longer meets the rated duration of
operation after the corresponding recharge period. The LFP batteries have a
life time expectancy of 6 years.
- Disconnect the old battery
- Reconnect the new battery ELW3 type luminaires switch into inhibit mode as shipped. To enable normal emergency operation; commissioning is needed through Interact Enterprise.
Imax (A | 25 | 29,6 |
---|---|---|
Tref (μs) | 214 | 350 |
MCB | 830/840/930/940 | TW/TWBU |
B-10 A | 13 | 10 |
B-13 A | 17 | 13 |
B-16 A | 21 | 16 |
C-10 A | 21 | 16 |
C-13 A | 28 | 21 |
C-16 A | 35 | 27 |
Emergency Lumen output by DC supplier
The luminous flux of the luminaire is 15% of the nominal luminous flux in
central battery emergency mode.
http://www.lighting.philips.com/main/systems/themes/service- tag.html
To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and iOS).
https://play.google.com/store/apps/details?id=com.philips.servicetag
Disconnect befae servicing
Luminaire has basic insulation between Low Voltage supp and control
conductors.
The light source and/or control gear and/or the external flexible cable
contained in this luminaire shall only be replaced by the manufacturer or his
service agent or a similar qualified person.
Storage, installation, use, operation and maintenance of the products needs to
be performed exactly according the instructions in this manual and/or other
instructions as may be prOllided by us to guarantee safe use of the product
over its entire lifetime. Failure to adhere to these instructions will
invalidate your entitlement to warranty. Bolts with indication of torque
strength on the drawing need to be tightened using a calibrated torque wrench.
Pre-assembled bolts need to be retightened again to the required torque
specification to assure maximum strength over lifetime.
This product contains a light source of energy efficiency class: see table or
label.
Zhaga-D4i and SR certified compatibility – For Zhaga-D4i/SR-Certified based
luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see
also: https://www.zhagastandard.org/products I
https://www.lighting.philips.co.uk/oem-emea/productsldriving-connected-
lighting). The functional compatibility of two SR-certified ancVor Zhaga-04i
controllers/sensors to be used in combination, as well as the override
possibility of any line-switch function used in an SR-based/Zhaga-04i
luminaire, is to be released by the master controller/sensor supplier. If
using a NEMA 7-pin socket on an SR-based luminaire, a full system verification
is required. Not following this advice carvwill cause risk of damage and non-
compliance for which Signify cannot take any responsibility.
© 2023 Signify Holding All rights reserved. This document contains information
relating to the product portfolio of Signify which information may be subject
to change. No representation or warranty as to the accuracy or completeness of
the information included herein is given and any liability for any action in
reliance thereon is disclaimed. The information presented in this document is
not intended as any commercial offer and does not form part of any quotation
or contract. Philips and the Philips Shield Emblem are registered trademarks
of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding
or their respective owners.
Signify Holding The Netherlands
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>