PHILIPS RC450B TrueLine recessed - icon

Product Family Code P max [W]
Flux Basic ELP/ELD/ELW
RC4S5B RC455X RC453X RC453B 20S 13.8W – 22.5W
28S / 36S / 40S / 42S 17.8W – 42W 23.8W – 48W
34S / 43S / 48S / 50S 21.5W – 49.5W 27.5W – 55.5W
Product Family Code Rim Size Max Weight
--- --- ---
Width [mm] Length [mm] Weight [kg]
RC455B 90-200 634-1970
RC455X 100-200 634-1970
RC453B 150-300 1195-1500
RC453X 150-300 1195-1500

PHILIPS RC450B TrueLine recessed - feagerPHILIPS
RC450B TrueLine recessed - feager1

Wieland (W)PHILIPS RC450B TrueLine recessed -
feager2PHILIPS RC450B TrueLine recessed - feager
3PHILIPS RC450B TrueLine recessed - feager
4PHILIPS RC450B TrueLine recessed - feager
5

Functional Notice for Emergency Lighting

Automatic emergency time selection
After installation and power up the driver will detect the battery and start the automatic detection process.

  • During automatic detection, the indicator LED will light up with short green flashes.
  • Between minimum 6 and maximum 30 seconds the TrustSight driver will set the battery type (number of cells) and will set the emergency output power accordingly.

After that, the system is defined and fully operational. The battery type definition has influence on the performance during the self-test and on the battery charge method. When the automatic battery detection process is disrupted, e.g. by switching off the  permanent mains, the detection process is stopped and the TrustSight emergency driver will go into emergency mode with the lowest output power. At a next power up, the automatic detection process will start again.

Periodic testing

Periodic tests of emergency lighting luminaires must be performed according to EN50172 clause 7.2.3 and 7.2.4.
Switch on in the emergency mode each month by simulation of a failure of the supply to the normal lighting for a period sufficient to ensure that each lamp is illuminated. Twice per year, each luminaire shall be tested for its full rated duration (at least 3hrs).
For more information please consult the TrustSight Gen 3 Design in guide. The latest version is available online.

LED indicator status

LED indicator (color/ flashing)| Error condition| Cause| Solution
---|---|---|---
Green / no flashing| | System OK, battery fully charged
Off| | Mains oft EM mode, Rest mode, test in progress
Green /slow (0.25s on, 125s oft)| | System Old battery is charging
Green / fast (0.255 on, 0.25s off)| | System O/C recently tested (< 5 days, Australia mode only)
Red /no flashing| Battery voltage too high or too low| No battery connected| Connect battery
| Wrong or bad battery connected| Replace battery
Red /fast (0.25s on, 0.25s oft)| Output voltage too low or too high| Wrong LED load connected| Connect right load and perform functional test
No load connected or output shorted| Wrong connection| Connect right load and perform functional test
Red/slow (0.25s on, 1.25s oft)| Failed test due to battery| Battery end of life Charger failure| Replace battery and perform duration test Replace driver
Red-green / fast
Fast flashing: (on-time = 0.25s, off-time = 0.25s) Slow flashing: (on-time = 0.25s, off-time = 1.25s)| | DALI device identification|
Green / short
on-time = 50ms, off-time = 0.95s)| | Battery detection|

Service
The battery should be replaced when it no longer meets the rated duration of operation after the corresponding recharge period. The LFP batteries have a life time expectancy of 6 years.

  1. Disconnect the old battery
  2. Reconnect the new battery ELW3 type luminaires switch into inhibit mode as shipped. To enable normal emergency operation; commissioning is needed through Interact Enterprise.
Imax (A 25 29,6
Tref (μs) 214 350
MCB 830/840/930/940 TW/TWBU
B-10 A 13 10
B-13 A 17 13
B-16 A 21 16
C-10 A 21 16
C-13 A 28 21
C-16 A 35 27

PHILIPS RC450B TrueLine recessed - feager5

Emergency Lumen output by DC supplier
The luminous flux of the luminaire is 15% of the nominal luminous flux in central battery emergency mode.

PHILIPS RC450B TrueLine recessed - feage6http://www.lighting.philips.com/main/systems/themes/service- tag.html

To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and iOS).

https://play.google.com/store/apps/details?id=com.philips.servicetag

Disconnect befae servicing

Luminaire has basic insulation between Low Voltage supp and control conductors.
The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be prOllided by us to guarantee safe use of the product over its entire lifetime. Failure  to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
This product contains a light source of energy efficiency class: see table or label.
Zhaga-D4i and SR certified compatibility – For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products I https://www.lighting.philips.co.uk/oem-emea/productsldriving-connected- lighting). The functional compatibility of two SR-certified ancVor Zhaga-04i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-04i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice carvwill cause risk of damage and non- compliance for which Signify  cannot take any responsibility.
© 2023 Signify Holding All rights reserved. This document contains information relating to the product portfolio of Signify which information may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or their respective owners.

Signify Holding The Netherlands

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals