Mounting instruction

PHILIPS BWP420 Uni Wall Mount - Icon 1

Product Type| LEDs| Power| Input Voltage| CCT| Beam Angle| Weight
---|---|---|---|---|---|---
BWP420 LED 20W| 24| 20W| 220-240V| 3000/4000/5000K| /| 1.4KG
BWP421 LED 40W| 48| 40W| 220-240V| 3000/4000/5000K| /| 3.1KG
BWP421 LED 60W| 48| 60W| 220-240V| 3000/4000/5000K| /| 3.1KG
Item| CCT| Power/VV| OPTIC| Class| Surge Protection Level
---|---|---|---|---|---
BWP420| WW (3000K) NW (4000K) CW (5000K)| 20W| /| | 2KV
BWP42 I| 40W| /| 4KV
60W| /
This product contains a light source of energy efficiency class: D
Product Type| Start(Inrush)
Current(A)
lpeak(A)| Start Current
Duration(us)
/T(@50% off-peak)(us)| Touch current or
protective conductor
current(mA)| Maximum Number of Luminaire on MCB
16A Type B(pcs)| Maximum Number of
Luminaire on MCB
16A Type C(pcs)
---|---|---|---|---|---
BWP420 LED 20W| 35| 245| 0.7| 13| 22
BWP421 LED 40W| 48| 260| 0.7| 10| 16
BWP421 LED 60W| 55| 280| 0.7| 8| 13

PHILIPS BWP420 Uni Wall Mount - Figure 1

Product Type L1 L2 W H1 H2
BWP420 196.5 121 168 112.5 82.5
BWP421 285.7 183 242 143.5 94.6
4pcs ST3.530-50mm or ST4.2*30-50mm screw with expansion tube. The

length of screw depends on the depth of expansion tube.
---|---|---
Drill holes on the mounting surface| Remove the backplane| Install a backplane fixed to the wall
(Mounting screws are not including in the lamp)
| |
60245 VDE 3*1.0mm 2,IEC57(YZW) Wiring| Install the luminaire on the mounting
backboard and adjust it to the proper angle| Installation complete

Please inform yourself about the local waste disposal. separation and collection system for electrical and electronic products and packaging Please act according to your local rules and do not dispose your old product and packaging with your normal household waste. The correct disposal of the packaging, your product and/ or batteries will help prevent potential negative consequences for the environment and human health. Batteries should be disposed separately from the municipal waste stream via designated collection facilities. When disposing a product that contains non-user replaceable batteries, the non-user replaceable batteries shall be removed by a professional.

Warming

  1. The luminaire shall be installed by a qualified electric an and wired in accordance with the latest IEEE electrical regulations or the national requirements.
  2. Turn power off before inspection, installation or removal.
  3. The light source and/or control gear contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
  4. Refer to technical datasheet for additional electrical properties to ensure safe installation.
  5. Luminaire installed must not be in contact with combustible materials.
  6. Ensure power supply cables (L-N / L-N-E) are connected correctly before switching on.

Maintenance

  1. Ensure power supply is switched off before attempting any maintenance work.
  2. Periodic cleaning of the luminaire optical lens cover will ensure maximum optical efficiency.
  3. Luminaire optical lens cover shall be cleaned with clean water and non-abrasive soap, cleaner or detergent solution.

Caution

  1. The Luminaire must be used within the applicable product specifications installation instructions and environmental conditions for storage & operations according to application guidelines provided by Signify for product Warranty to be valid.
  2. Due to improper transportation of the packaging damage, and then lead to the deformation of the luminaire or broken, the supplier does not assume the responsibility for the resulting.

Signify Luminaires (Shanghai) Co., Ltd.
Address: 2F, Building 1, No. 2555 Hechuan Road,
Minhang District, Shanghai, P.R. China