Product Information

Specifications

  • Compatibility: UniversalFit
  • Usage: Replacement for fluorescent lamps
  • Installation: Requires ballast listed in Philips TLED compatible ballast list
  • Temperature Range: -4F (-20C) to 113F (45C)
  • Compliance: UL Listed

Product Usage Instructions

Installation Guide
The Installation Guide provides important information and notes for the installation and operation of the UniversalFit lamps. Please adhere to the following points:

  • Not compatible with luminaires using a remote starter.
  • Modifications void the warranty.
  • Must replace fluorescent lamps as specified on the product label.
  • Install with ballast listed in Philips TLED compatible ballast list.
  • Refer to www.philips.com/lighting for the latest ballast compatibility guide.

Instructions for Philips UniversalFit LED Lamps

  1. Switch off power to the luminaire.
  2. Remove diffuser (if provided).
  3. Remove existing fluorescent lamps from the luminaire.
    • Note: Verify the fluorescent tube type is listed on the label of Philips UniversalFit LED lamp.
  4. Install Philips UniversalFit LED lamp (one for each fluorescent lamp removed, ensure pins are firmly seated in the lamp holders).
  5. Replace diffuser (if removed in step 2).
  6. Switch on power to the luminaire.

Type A Lamp Instructions
This lamp is intended for direct substitution of a fluorescent lamp and operates from the integral ballast without modifications to the fluorescent luminaire.

Safety Information
Lamps must be operated within an ambient fixture temperature of -4F (-20C) and 113F (45C) to ensure UL compliance. This device is not intended for use with emergency exits or for emergency lighting.

FAQ

  1. Q: Can I modify the product without voiding the warranty?
    A: No, modifications to the product will void the warranty.

  2. Q: What temperature range should the lamps be operated within?
    A: Lamps must be operated within an ambient fixture temperature of -4F (-20C) and 113F (45C) to ensure UL compliance.

The Installation Guide contains important information and notes regarding the installation and operation of the UniversalFit lamps. Please note the important points below:

  • Not compatible with luminaires that use a remote starter.
  • Modifications to the product void the warranty.
  • Suitable to replace fluorescent lamps as specified on the product label.
  • Must be installed with ballast which is listed in Philips TLED compatible ballast list.
  • Please refer to www.philips.com/lighting for latest ballast compatibility guide.

For Philips UniversalFit LED Lamps

PHILIPS-3241-Universal-Fit-LED-Lamp- \(1\)

See reverse side for installation instructions.

Philips UniversalFit LED Lamps

Instructions

  1. Switch-off power to the luminaire

  2. Remove diffuser (if provided)

  3. Remove the existing fluorescent lamps from the luminaire.
    Note: Verify the fluorescent tube type is listed on the label of Philips UniversalFit LED lamp.

  4. Install the Philips UniversalFit LED lamp (one for each fluorescent lamp removed, ensure pins are firmly seated in the lamp holders).

  5. Replace the diffuser (if removed in step 2).

  6. Switch on power to the luminaire.

CAUTION – IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT  THE MANUFACTURER
CAUTION – RISK OF FIRE. DO NOT INSTALL IN A PRE-HEAT LUMINAIRE
CAUTION – RISK OF FIRE. PERFORM A VISUAL INSPECTION TO ENSURE LAMPHOLDERS ARE N OT DAMAGED OR LOOSE. IF DAMAGED, CORRODED, CHARRED, BLACKENED, OR LOOSE, CONTACT A QUALIFIED ELECTRICIAN FOR PROPER REPLACEMENT.

  • TYPE A LAMP – Intended for direct substitution of a fluorescent lamp and operating from the integral ballast without any modifications to the fluorescent luminaire.
  • This device complies with Part 18 of the FCC Rules.
  • THIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY COMMUNICATIONS EQUIPMENT OR OTHER CRITICAL NAVIGATION OR COMMUNICATION EQUIPMENT OPERATING BETWEEN 0.45 – 30MHZ.

This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

LAMPS MUST BE OPERATED WITHIN AN AMBIENT FIXTURE TEMPERATURE OF -4F (-20C) AND 113F (45C) TO ENSURE UL COMPLIANCE. This Class B digital apparatus complies with Canadian ICES-005.
THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS or NOT FOR
EMERGENCY LIGHTING.

  • 1(N-1) rule applies, meaning:
    • Minimum 3-lamps be replaced in a 4-lamps ballast.
    • Minimum 2-lamps be replaced in a 3-lamps ballast.

© 2023 Signify Holding @ignify

Signify reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
04/2023 www.philips.com/lighting
Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. and are used under license

  • Signify North America Corporation 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807, USA
  • Markham, ON, Canada L6C 2S3
  • 3241 653 18514

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals