Honeywell SEARCHLINE EXCEL PLUS Gassing Test Cell User Guide

May 15, 2024
Honeywell

QUICK START
GUIDE
GASSING TEST CELL
SEARCHLINE EXCEL™ EDGE
SEARCHLINE EXCEL™ PLUS

SEARCHLINE EXCEL PLUS Gassing Test Cell

The gassing test cell allows the Searchline Excel™ Plus and Searchline Excel™ Edge calibration to be checked using a user-specified gas concentration, as an alternative to the standard functional test filters.
CAUTION
Prerequisite for calibration check using the gassing test cell is installation of the Honeywell Fixed Platform App to a suitable handheld device.
The test gas must be the same as the gas calibration of the Searchline Excel Plus or Searchline Excel Edge units and ideally the concentration should be between 2  and  5  LEL.m, never below 1 LEL.m.
Note
For Universal Calibration units any of Methane, Ethane, Propane, Butane, Ethylene can be used. Natural gas mixes can also be tested.
Note
Cross-calibration is not recommended. Typical values for crosssensitivity are not sufficiently precise to enable valid calibration checks using the gassing test cell.
Response tests can easily be performed with the functional test filters.
Refer to the Technical Manual for more information.
WARNING
Take necessary precautions to ensure safety when dealing with high concentration gasses.
The gassing test cell supplied by Honeywell Analytics (Part  No:  2017B0185) is 170  mm (6.7  in) long, weighs 958  g (2.11 lb), with gas path 138.8  mm (5.46 in).
The following table outlines the response expected when using this gassing test cell:

Gas type| LEL of the gas (% v/v)| Concentration applied (% v/v)| Calcul ated response with 138.8 mm (5.46 in) gas path (LEL.m)| 4-20 mA output (mA)
---|---|---|---|---
Methane| 4.4| 80| 2.5| 12.0
Ethane| 2.4| 43| 2.5| 12.0
Propane| 2.7| 31| 2.5| 12.0
Butane| 1.4| 25| 2.5| 12.0
Pentane*| 1.1| 20| 2.5| 12.0
Ethylene| 2.3| 42| 2.5| 12.0
Propylene| 2.0| 36| 2.5| 12.0

  • Pentane cannot be used with the gas sing test cell . At normal temperatures, this s ubs tance does not vaporise s ufficiently to give a  usef ul signal in  the  short path of the gas sing test cell .
    WARNING
    These gases are flammable and some are toxic. Take appropriate precautions when handling.

CONNECT THE GASSING TEST CELL

  1. Connect the gassing test cell to the receiver. Ensure the locking tab clicks into the right position.
  2. Rotate the handle clockwise to lock the gassing test cell onto the receiver.Honeywell SEARCHLINE EXCEL PLUS Gassing Test Cell - GASSING TEST CELL 1
  3. Zero the receiver with the empty gassing test cell.
  4.  Apply the test gas to the gassing test cell. Avoid pressurising the test cell. Wait for the receiver output to stabilise.
  5.  Check if the receiver output is as indicated in the table above, ±5% FSD.
  6. Remove the test gas from the gassing test cell.
  7. Remove the gassing test cell.
  8. Re-zero the receiver.

Note
Field calibration is not supported. If result is not as expected contact an authorized service centre.
NOTES
Please Note:

While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This publication is not intended to form the basis of a contract.

Find out more
www.sps.honeywell.com
Contact Honeywell Analytics:
Europe, Middle East, Africa
Life Safety Distribution GmbH
Tel: 00800 333 222 44 (Freephone no.)
Tel: +41 (0)44 943 4380 (Alternative no.)
Middle East Tel: +971 4 450 5800 (Fixed Gas Detection)
Middle East Tel: +971 4 450 5852 (Portable Gas Detection)
gasdetection@honeywell.com
Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
detectgas@honeywell.com
Asia Pacific
Honeywell Analytics Asia Pacific
Tel: +82 (0) 2 6909 0300
India Tel: +91 124 4752700
China Tel: +86 10 5885 8788-3000
analytics.ap@honeywell.com
Technical Services
EMEA: HAexpert@honeywell.com
US: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com
www.sps.honeywell.com
2017M1255 Issue 2
ECN-00034589
©2023 Honeywell Analytics

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals