  • Product Name: DD1 MINI Desiccant Dehumidifier
  • Manufacturer: EcoAir
  • Model: V1
  • Optimum Humidity Level: 40% – 60% Relative Humidity (RH)

Product Usage Instructions

Humidity Guide
The humidity level in your environment plays a crucial role in maintaining comfort and preserving your belongings. Ensure the relative humidity remains between 40% and 60% for optimal conditions.

Too Dry
Low humidity can lead to skin irritations, damage to wooden furniture, musical instruments, and artwork. Use the dehumidifier to prevent excess drying.

Too Wet
High humidity causes dampness, condensation, and can lead to mold growth. Protect your property and health by maintaining safe humidity levels.

Condensation Control
Condensation occurs when warm air meets cold surfaces, leading to moisture buildup. Open windows to expel excess humidity and allow the dehumidifier to reduce moisture levels effectively.

Important Safety Instructions

Refer to the user manual for detailed safety instructions to ensure safe operation of the dehumidifier.

Cleaning and Maintenance

Regularly clean the water tank, filters, and exterior of the dehumidifier to maintain optimal performance. Store the appliance in a dry place when not in use.

Troubleshooting

If you encounter any issues with the dehumidifier, refer to the troubleshooting section in the user manual for guidance on resolving common problems.

Contact Customer Support

If you have any further questions or need assistance, please contact our customer support team for help.

FAQ

  • How often should I clean the water tank?
    It is recommended to clean the water tank at least once a week to prevent bacterial growth and maintain efficient operation.

  • Can I leave the dehumidifier running continuously?
    Yes, you can leave the dehumidifier running continuously, especially in high humidity conditions to maintain optimal levels.

WELCOME

  • Thank you and congratulations for choosing an EcoAir dehumidifier to help you improve the air quality within your environment. Inside you will find many helpful tips on how to use and maintain your dehumidifier efficiently. Just a little preventative care can save you money and prolong the life of your dehumidifier.
  • The purpose of the dehumidifier is to remove the excess moisture in the air by detecting the humidity level in the room. By keeping humidity within recommended levels, a dehumidifier combats household damp, mould and mildew. Dehumidifiers can help to reduce the symptoms of asthma, allergies, and other respiratory health conditions. They can also be used to help dry laundry quicker and control moisture-based damage (such as the aftermath of flooding, leaks or rising damp) to valuable belongings and furniture.

HUMIDITY GUIDE

There will always be water vapour in the air. The water vapour (or commonly known as moisture) in the air is measured in Relative Humidity (RH) %. RH is the ratio of the actual amount of water vapour in the air to the amount it could hold when saturated expressed as a percentage. Too much or too little moisture in our homes can be unhealthy and uncomfortable. The optimum humidity level is between 40% and 60% (RH) where we feel most comfortable.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-2

Low humidity
Low humidity indoors causes excess drying which can trigger skin irritations such as eczema, chapped skin and dry nose. It can also damage possessions, such as wooden furniture, musical instruments and artwork by drying it out too much.

High humidity
High humidity indoors causes damp and condensation. The damp left by condensation can damage plaster, wall paper, furniture, vehicles, timber windows, doors and clothes. It can be harmful to our health when bacteria thrives, causing mould and fungus.

Maintaining safe levels of humidity
It is important to maintain a consistent humidity range to preserve furniture, paintings, door and window frames. High humidity causes swelling, corrosion, softening of glues and paint. Low humidity causes shrinking, cracking, warping of wood surfaces and gaps in joints, doors and windows. Frequent changes in humidity levels can accelerate damages to property and belongings.

Condensation

  • The warmer the air, the more moisture the air can hold than colder air. So, when the air inside the house becomes colder, the moisture contents in the air becomes saturated, and gets heavier resulting in moisture concentration on the coldest parts of the house particularly on the windows, bathroom mirrors and walls. This is condensation, caused by a sudden increase in humidity, cooking, showers, drying clothes, inadequate ventilation and poor thermal insulation.
  • Condensation does not disappear instantly even with the dehumidifier on. Where excessive condensation appears for example, on your windows, you may want to open your windows to expel the excess humidity for several minutes. It will take a while for the condensation to generally increase the humidity in the room. Once the humidity level in the room around the dehumidifier is increased above the level you have set on the dehumidifier, it will then begin the dehumidification process.

IMPORTANT SAFETY INSTRUCTIONS

WARNING!
This dehumidifier is intended for use in domestic households and similar working and residential environments and is not intended for outdoor use. It must be used only as a domestic appliance. EcoAir cannot be held liable for damage resulting from incorrect or improper use or operation

  • Do not alter or modify the appliance’s characteristics in any way. Should repairs be necessary, con-tact EcoAir’s Authorised Service Centre. Self-servicing or unauthorised servicing can be dangerous.
  • The appliance must be installed in accordance with the relevant national legislation.
  • The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Children and pets should be supervised to ensure they do not play with the appliance.
  • Do not use the appliance If the power cable, cord is damaged It must be replaced by an EcoAir’s Authorised Service Centre.
  • The appliance must always be placed in an upright position on an even level surface to avoid any damage, during use or transportation and when put into storage.
  • The appliance must be plugged into a grounded 3-prong outlet and ensure that the voltage matches the rated specifications. If in doubt, check with a qualified technician.
  • Do not use with extension cables or multi sockets. Do not pull or place strain on the power cord when moving appliance.
  • Always unplug the appliance before cleaning or maintenance or when not in use.
  • The appliance must not be placed or used where the atmosphere may contain combustible gasses, oil or sulphur or solvent, or near heat sources (such as heaters or in server rooms) or excessive dust.
  • Do not place or rest any objects on the appliance and do not cover while in use. Always observe the minimum room size for storing and operating the appliance.
  • Allow a minimum of 40 cm clearance around the appliance. Do not place any objects in close proxim-ity to the appliance.
  • Filter must be cleaned every 2 weeks to avoid dust building up internally causing overheating and malfunction.
  • To protect against electric shocks, do not immerse or spray the appliance or any of its parts in water.
  • Ensure the air inlet and outlet are not blocked or covered when in use.
  • Do not insert fingers or any objects into the air inlet or outlet openings.
  • Do not operate or store the appliance under direct sunlight.
  • Always switch of the power before unplugging from the socket.
  • Do not leave the appliance running or plugged in over a long period of time unattended. Leaving unattended electrical appliances running is unsafe.
  • Always make sure your hands are dry when operating the appliance.
  • Only operate the appliance within the specified operating temperature range.
  • Do not run power cord under carpeting, or cover with rugs or runners. Arrange the cord away from areas where it may become a trip hazard.
  • This appliance must not be used outdoor or wet areas such as bathrooms.
  • Do not use the Laundry Mode function over a long period of time or unattended. When drying laun-dry, do not place laundry on the appliance. Always ensure the laundry is placed a safe distance from the dehumidifier at least 40cm.
  • Always clean the filter and cover the dehumidifier with a dust sheet when storing the dehumidifier.

BS PLUG WIRING

  • Should it be necessary to change the plug, please note the wires in the mains lead are colour coded as follows:
    • BLUE – NEUTRAL
    • BROWN – LIVE
    • GREEN AND YELLOW – EARTH
  • In the event that the colours of the wires in the mains lead of this appliance do not corre-spond with the coloured markings identifying the terminals in your plug, proceed as follows:
    1. The BLUE wire is NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK.
    2. The BROWN wire is LIVE and must be connected to the terminal which is marked with the letter L or coloured RED.
    3. The GREEN/YELLOW is EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN or GREEN/YELLOW.
    4. Always ensure that the cord grip is positioned and fastened correctly.
    5. If a 5A (BS 1363) fused plug is used it must be fitted with a 5A -fuse.
      If in doubt consult a qualified electrician.
      Please note the Earth, Neutral and Live Terminals are marked as E , N and L respectively.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-4

THE APPLIANCE & ACCESSORIES

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-5

  • A1 Control Panel
  • A2 Louvre
  • A3 Air Outlet
  • A4 Water Level Indicator
  • A5 Handle
  • A6 Water Tanks
  • A7 Grip Handle
  • A8 Filter
  • A9 Air Inlet

Accessories List

B1 User Manual

IMPORTANT SAFEGUARDS

WHERE TO POSITION YOUR DEHUMIDIFIER?
Ensure the unit is a safe distance away from a wall or furniture and away from direct sunlight.
TIP: Position the dehumidifier in the dampest room or somewhere central like a landing or a hallway. As long as the internal doors are open the excess moisture from all of the rooms in the house will migrate naturally towards the dehumidifier and be processed.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-7

DO NOT PLACE OBJECTS ON OR OVER THE APPLIANCE
Ensure the air inlet (A9) and air outlet (A3) are not obstructed. Obstruction will cause overheating and malfunction.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-8

DRYING YOUR LAUNDRY
Never place wet laundry over the appliance. Dry the laun-dry on a rack with a minimum distance of 40 cm.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-9

ROOM SIZE
Never use in small confined area. (Broom cupboard, boiler room, unventilated rooms, in close proximity to a heat source such as heater, tumble dryer, cooker).

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-10

DO NOT SPLASH

  • Do not wash the appliance or immerse in water
  • Do not allow water to drip on to the appliance

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-11

PLACE ON EVEN LEVEL FLOOR

  • Always operate appliance on an even level floor to avoid leakage
  • If appliance is on carpet, ensure the appliance is stable and level

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-12
IMPORTANT

  * Do not move the appliance or remove the water tank when the dehumidifier is running. It may cause damage, electric shock, water leak or spills.
  * After turning the dehumidifier off, do not remove the power plug from the power socket immediately, allow the appliance to cool down for a minimum 5 minutes to help protect the internal components.
  * Dusty, building sites or an industrial environment where particles can clog up the filter or internal components.

INSTALLATION

PLEASE READ IMPORTANT SAFEGUARDS BEFORE INSTALLATION

FIND A SUITABLE POSITION

  • Position the dehumidifier in the dampest room or somewhere central like a landing or a hallway. As long as the internal doors are open, the excess moisture from all of the room in the house will migrate naturally towards the dehumidifier and be processed.
  • If there is a problematic area or a room in a high humidity level, use a hygrometer to measure (available to purchase at ecoair.org) in the property, you may wish to place it in that area initially. Once the problem is settled you may wish to relocate to the location above.
  • Please refer to the important safeguards on the previous pages when positioning the dehumidifier, such as a safe distance away from the wall, avoid confined areas, ensure floor is even and level surface.

INSTALLING THE DEHUMIDIFIER

  • Unpack the dehumidifier and plug in to the socket.
  • Ensure there is a minimum distance of 40 cm around the dehumidifier.
  • Check that the dehumidifier is level to avoid any water leaks.
  • Turn on the dehumidifier to start dehumidification.

ZEOLITE

  • When you first use the dehumidifier and periodically thereafter you may notice a smell coming from the dehumidifier. This is caused by the Zeolite desiccant material and is NOT a sign that the dehumidifier is faulty, nor is it harmful to humans or pets.
  • The Zeolite absorbs odours from items such as cigarettes, cosmetics, hair sprays, building materials and new furniture and then when the desiccant is heated the smell is discharged into the room. (This smell has been described as being like a burning smell or a sour smell). This is normal and will NOT last long, nor is it a sign of a fault.

INITIAL OPERATION

  • When you first use your dehumidifier it will work hard to reduce the room humidity to your set target humidity. This is the time when it will produce most of the water and need emptying more frequently. As the room become dryer, the dehumidifier collects less water. This is normal.
  • Once the power is restored after a power failure, the dehumidifier will continue to operate at the selected settings prior to the power failure.

CONTROL PANEL

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-13

  1. Power Key – Turn unit on ON/OFF.
  2. Dry Mode – Select AUTO or ECONOMY or HI settings.
  3. Swing Mode – Select UP FRONT WIDE or HOLD.
  4. Timer Key – Select 2 or 4 or 8 hours’ timer on.
  5. Laundry Mode – Select NORMAL or TURBO modes.
  6. Water Full Indicator – Indicator lights up when the water tank is full or incorrectly installed.
  7. Check Indicator – Indicator lights up when the unit needs attention.

OPERATION

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-22
ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-23
ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-24
ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-25
ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-26
ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-27

EMPTYING THE WATER TANK

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-28

The Water Full/Check Indicator lights up when the water tank is full. The appliance will stop operating. Allow to stand for approximately 30 minutes to ensure all water collected drips into the water tank.

  1. Gently pull the water tank out. Wipe dry the internal compartment

  2. Lift by the handle gently.

  3. Remove the tank lid.

  4. Pour the water away.

  5. Clean the water tank, restore the cover and handle.

  6. Insert the water tank back into to the correct position. (The Water Full light indicator illumi-nates if the water tank is not correctly in position. If this happens, reinsert again).
    NOTE :

    • Clean the water tank with mild detergent if necessary. Do not use solvent, abrasive or hot water. (After Step 4).
    • When cleaning the water tank, take caution to avoid damaging the float.
    • Do not tilt the dehumidifier when removing the water tank. This is to prevent water leaking which may cause electric shock.

CLEANING, MAINTENANCE & STORING THE APPLIANCE

  • STEP 1 – CLEANING YOUR FILTER
1. Turn off and leave for 5 minutes, then unplug the dehumidifier. Remove the filter.
2. Clean the filter with a brush or vacuum clean-er. (Washing will weaken the germicidal effect of the filter).
3. Reinsert the filter back into position.  

Tip: Clean your filter every 2 weeks to keep your air clean and prolong the life of your dehumidifier. The frequency will depend on conditions of opera-tion. Filter must be cleaned every 2 weeks to avoid overheating and malfunction.
Note: If the filter is covered with dust, the airflow and the performance of the dehumidifier will be affected.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-29

  • STEP 2 – REPLACING YOUR FILTER
    It is recommended that the outer filter is replaced every 6 months for optimal performance and hygiene standards. To purchase a replacement filter please visit: www.ecoair.org.

  • STEP 3- CLEANING YOUR DEHUMIDIFIER

1. Turn off and leave for 5 minutes, then unplug the dehumidifier.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-31

2. Clean the surface with a soft damp cloth.
3. Dry thoroughly with a towel after cleaning.
4. For cleaning tank, see Emptying the Water Tank section.  

Caution:

  * Do not wash the unit or immerse in water.
  * Do not let water drip into the air inlet or outlet.
  * When cleaning the water tank, take caution to avoid damaging the float.
  • STEP 4 – STORING YOUR DEHUMIDIFIER
1. Turn off the dehumidifier, wait 30 minutes and unplug the dehumidifier from the power socket.
2. Leave the dehumidifier to drain for approximately one day. Clean and dry the water tank.
3. Clean the filter and the dehumidifier. Cover the dehumidifier to prevent it from gathering dust. Store upright in a cool dry place.
4.  Do not expose to direct sunlight.

TROUBLESHOOTING

CHECK THE FOLLOWING POINTS BEFORE CONTACTING TECHNICAL SUPPORT.

ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-32 ecoair-DD1-MINI-Air-Dehumidifier-Desiccant-fig-33

Dust can build up internally inside the dehumidifier, causing obstruction to airflow and over-heating. This will cause malfunction. Common symptoms are Check Light On, Water Leaking and Not Collecting Water (see details above). When this happens, you will need to request a service at our Service Centre. * Clean the filter regularly (recommended every 2 weeks) to avoid malfunction.
In the unlikely event of a problem with your product, please refer in the first instance to: ECOAIR TECHNICAL SUPPORT www.ecoair.org/support

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals