Model No.: VF120, VF240
INSTALLATION & USER MANUAL
Please read and save these manual
Please read these manual carefully before attempting to install, operate, or
service the products. Failure to follow the instructions may result in
personal injury or property damage.
Please retain this manual for future reference.
Thank you for purchasing this SUPROCKY product.
Safety Considerations
WARNING
To reduce the risk of fire, electric shock or personal injury, please observe the following:
- Please use this equipment in the manner prescribed by the manufacturer. If you have any questions, please contact the manufacturer.
- Installation work and electrical wiring must be completed by qualified personnel in accordance with all applicable codes and standards, including fireproof construction.
- The ceiling joist must bear a static load greater than five times the weight of the product.
- Do not damage electrical wiring and other hidden utilities when cutting or drilling into walls or ceilings.
- Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting mains to prevent power from being switched on accidentally. When the service disconnecting mains cannot be locked, securely, fasten a prominent warning device, such as a tag, to the service panel.
- Do not place the switch where the bathtub or shower can reach.
- When the product is no longer in use, it must not be left in place, but moved out of the way to prevent it from possibly falling.
- Do not disassemble the unit for reconstruction. It may cause fire or electric shock. This product must be grounded.
CAUTION
- Do not install this fan in areas where the temperature may exceed 60°C (140°F).
- Before installation, make sure the unit is facing the correct direction.
- Ensure that the power supply voltage is 120V, 60Hz.
- Comply with all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
- Protects wires from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
- Do not bend the wires.
- Do not use to discharge hazardous or explosive substances or vapors.
- Always turn off the power before working near the fan or motor.
Description
SUPROCKY in-line fan is designed for residential or light commercial
applications, this powerful ventilation fan often be placed in the roof space
or ceiling void, it is much quieter than traditional fan as the fan is located
away from the living space.
SUPROCKY in-line fan is designed with centrifugal fan, so it can use less
energy to move more air. Less energy also means less overheating and motor
failure, saving you money on maintenance.
Unpacking
Carefully open the package containing the in-line fan. Check that all items are included according to the specifications and that all parts are undamaged.
Dimensions
No. | Part Name |
---|---|
① | body |
② | adapter |
③ | junction box cover |
④ | bracket |
⑤ | extension bracket |
⑥ | fan |
Dimensions: mm (inch)
Model No. | A | B | C | D | E | F | G | H | I |
---|---|---|---|---|---|---|---|---|---|
VF120 | 300 | ||||||||
(11.8) | 295 | ||||||||
(11.6) | 210 | ||||||||
(8.3) | 440 | ||||||||
(17.3) | 245 | ||||||||
(9.6) | 97 | ||||||||
(3.8) | 235 | ||||||||
(9.3) | 40-79 | ||||||||
(1.6-3.1) | 375-518 |
(14.8-20.4)
VF240| 340
(13.4)| 330
(13)| 240
(9.4)| 490
(19.3)| 270
(10.6)| 145
(5.7)| 275
(10.8)| 40-110
(1.6-4.3)| 412-550
(16.2-21.7)
InstallationⅠ (between joists)
- Disconnect the power from the outlet before starting the installation.
- Attach the adapters to the unit with screws. (Fig.1)
- After confirming the installation direction of the unit, attach the brackets to the unit with screws. (Fig.2) Dimensions: mm (inch)
- If the distance between the joists is less than A (table 1), lock one side of the expansion bracket to the shortest and fix it to the bracket with screws, while the other side will be kept sliding for easy adjustment during installation; (Fig.3)
Model No.| VF120| VF240
---|---|---
A| 440 (17.3)| 480 (18.9)
(table 1) If the distance between the joists is greater than A (table 1), lock one side of the expansion bracket to the longest and fix it to the bracket with screws, while the other side will be kept sliding for easy adjustment during installation. (Fig.4)
- Lift the unit between the joists and attach it with long screws. (Fig.5)
For best results, mount the unit as horizontally as possible.
Installation Ⅱ (on joists)
- Disconnect the power from the outlet before starting the installation.
- Attach the adapters to the unit with screws. (Fig.6)
- After confirming the installation direction of the unit, attach the brackets to the unit with screws. (Fig.7) Dimensions: mm (inch)
- If the distance between the joists is less than B (table 2), lock one side of the expansion bracket to the shortest and fix it to the bracket with screws, while the other side will be kept sliding for easy adjustment during installation; (Fig.8)
(table 2)
Model No. | VF120 | VF240 |
---|---|---|
B | 370 | |
(14.6) | 410 |
(16.1)
If the distance between the joists is greater than B (table 2), lock one side of the expansion bracket to the longest and fix it to the bracket with screws, while the other side will be kept sliding for easy adjustment during installation. (Fig.9)
- Place the unit between the joists and attach it with long screws. (Fig.10)
For best results, mount the unit as horizontally as possible.
Installation Ⅲ (vertically on joists or pillars)
- Disconnect the power from the outlet before starting the installation.
- Attach the adapters to the unit with screws. (Fig.11)
- After confirming the installation direction of the unit, attach the brackets to the unit with screws. (Fig.12) Dimensions: mm (inch)
- If the distance between the joists is less than C (table 3), lock one side of the expansion bracket to the shortest and fix it to the bracket with screws, while the other side will be kept sliding for easy adjustment during installation; (Fig.13)
Model No.| VF120| VF240
---|---|---
C| 370
(14.6)| 410
(16.1)
(table 3) If the distance between the joists is greater than C (table 3), lock one side of the expansion bracket to the longest and fix it to the bracket with screws, while the other side will be kept sliding for easy adjustment during installation. (Fig.14)
- Lift the unit between the pillars and attach it with long screws. 5. (Fig.15)
For best results, mount the unit as horizontally as possible.
Wiring Diagram
SUPROCKY in-line fan come with a power cord, if you need to replace the power cord, please follow these steps:
- Remove junction box cover and secure conduit or wire holder to junction box cover knockout hole.
- Using wire nuts, connect house power wire as shown in the wiring diagram. (Fig.16)
- Replace junction box cover.
Specifications
Model No.| V| Hz| Op. Temp.| Op. Humidity| Power
Consumption (W)| Air Delivery (CFM)| Weight (lb)
---|---|---|---|---|---|---|---
VF120| 120| 60| -4℉-140 ℉| 0-90%| 54| 170| 13.5
VF240| 105| 300| 17.9
Warranty
SUPROCKY ensure the product components will be free of material defects in
workmanship or materials for a period of 3 years following the date of initial
purchase of such product by a customer. This warranty is limited to the repair
or replacement of defective equipment.
If it is necessary to return unit for service, customer is solely responsible
for proper packaging, transportation costs. Customer must initiate warranty
process by contacting SUPROCKY. Do not send any component or product back to
SUPROCKY without return material authorization.
This limited warranty does not apply to any part or component that is damaged
in transit or when handling, has been subject to misuse, corrosion, chemicals,
acts of God, has not been installed, operated or serviced according to the
seller’s instructions, or has been operated beyond the factory rated capacity
or has been altered in any way.
Routine maintenance is not covered by this warranty.
This limited warranty is void if defect(s)result from failure to have this
unit installed by a qualified heating and air conditioning contractor.
SUPROCKY shall not be responsible for loss of use of any product, loss of
time, inconvenience, or damage to other equipment, or any other indirect or
consequential damage with respect to property whether as a result of breach of
warranty, neglect, or otherwise.
Extraordinary Quality
Led by SUPROCKY Warranty QR Code
www.suprocky.com/warranty
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>