CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE: For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.
Wiring the 5530m communicators to Honeywell Vista 50P for events reporting and remote control via keybus:

![Honeywell Vista 50P Wiring Uplink’s Communicators and Programming the Panel

Wiring and Programming Uplink Communicators to Honeywell Vista 50P
Wiring the 5530m communicators to Honeywell Vista 50P for events reporting and remote control via keyswitch :

![Honeywell Vista 50P Wiring Uplink’s Communicators and Programming the Panel

Programming the Honeywell Vista 50P Alarm Panel via the Keypad

Enable Contact ID reporting:

Keypad Display Keypad Entry Action Description
Disarmed 4140,8,00 To enter programming mode.
Program mode *30, 1 To select Touch tone for dialing method.
PABX *32 To qo to “Primary subscriber Account #”.
Prim.Subs. Acct# 01, 02, 03, 04 Enter desired account number (in HEX). 1234

is just an example.
Primary Phone| 123456, | Enter desired phone number (123456 is an example). Press to save.
Enter fill field| 45| To qo to “Primary format”.
Primary format| 1| 1 is the value for ContactlD.
Low Speed Format|
81, 01, 01, | To enable Open/Close reports.
Enter fill field|
99| To exit programming mode.

Enable Keyswitch Zone and Status Output:

Keypad Display Keypad Entry Action Description
Disarmed 4140,8,00 To enter programming mode.
Program mode *15, 1 To assign keyswitch to partition 1 (zone 07).
Confirmation of arming ding *40, 1 To enable Open/Close reports for

Keyswitch.
Normally closed or EOLR| 94, 94| Press 94 until “200” is shown in the lower right corner.
Alt Program Mode|
20, 1| To configure pin 5 on 17 connector to follow Keyswitch RED behavior.
Enter fill field| 99| Press 99 a couple of times until you exit programming mode.

Programming an Alpha Keypad Address

Keypad Display Keypad Entry Action Description
DISARMED 4140,8,00 To enter Programming Mode.
Program Mode #93 To go to “Menu Mode”
Zone Prog. ? 0 … 1 Press 0 until “Device Prog.” is shown. Press 1 to enter.

Device Address
01-30, 00=Quit| 21| To enter Address 21
21 Device Type| 1
| To select Alpha Keypad Console
21 Console Part.| 1| To assign the Alpha Keypad Console to Partition 1
21 Sound Option| | Press
to exit from Device Address 21 .
Device Address
01-30, 00=Quit| 22 | To enter Address 22
Note: This Address is optional — if 2s partition is used
22 Device Type| 1
| To select Alpha Keypad Console
22 Console Part.| | To assign the Alpha Keypad Console to Partition 2
22 Sound Option| | Press to exit from Device Address 22 .
Device Address
01-30, 00=Quit| 00
| To exit the Device Address menu.
Quit Menu Mode ? 1=YES 0=NO| 1| To exit Menu Mode.
Program Mode| *99| To exit Programming Mode
| | Note : The Vista 50P supports up to 8 Partitions.
You will need to repeat the programming steps for Device Addresses 23…28 according to the number of partitions.

Switching from Keyswitch to Keybus

  • Wire the device to the panel as described on the respective wiring schemeabove.
  • Use the Sync with Panel feature from the Settings menu of the Uplink mobileapp.

The device will apply the new configuration automatically.
NOTE 2: When switching the wiring of the device, make sure that the device is not powered on.
NOTE 3: When synchronizing or disabling and enabling the Arming/Disarming feature from the mobile application, make sure:

  •  the device is powered and connected to cellular network;
  • the panel is not in programming menu/mode.

After enabling the Arming/Disarming feature it may take up to 1 minute for the device to apply the new configuration.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>