CAUTION:
- It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
- Do not route any wiring over circuit board.
- Full panel testing, and signal confirmation, must be completed by the installer.
NEW FEATURE: For 5530M Communicators, the status of the panel can be
retrieved not only from the status PGM but now also from the Open/Close
reports from the dialler.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the
initial pairing procedure.
Wiring the 5530m communicators to Honeywell Vista 50P for events reporting and
remote control via keybus:
![Honeywell Vista 50P Wiring Uplink’s Communicators and Programming the Panel
- keybus](https://manuals.plus/wp-content/uploads/2024/03/Honeywell-Vista-50P- Wiring-Uplinks-Communicators-and-Programming-the-Panel-keybus.png)
Wiring and Programming Uplink Communicators to Honeywell Vista 50P
Wiring the 5530m communicators to Honeywell Vista 50P for events reporting and
remote control via keyswitch :
![Honeywell Vista 50P Wiring Uplink’s Communicators and Programming the Panel
- keyswitch](https://manuals.plus/wp-content/uploads/2024/03/Honeywell-Vista- 50P-Wiring-Uplinks-Communicators-and-Programming-the-Panel-keyswitch.png)
Programming the Honeywell Vista 50P Alarm Panel via the Keypad
Enable Contact ID reporting:
Keypad Display | Keypad Entry | Action Description |
---|---|---|
Disarmed | 4140,8,00 | To enter programming mode. |
Program mode | *30, 1 | To select Touch tone for dialing method. |
PABX | *32 | To qo to “Primary subscriber Account #”. |
Prim.Subs. Acct# | 01, 02, 03, 04 | Enter desired account number (in HEX). 1234 |
is just an example.
Primary Phone| 123456, | Enter desired phone number (123456 is an example).
Press to save.
Enter fill field| 45| To qo to “Primary format”.
Primary format| 1| 1 is the value for ContactlD.
Low Speed Format| 81, 01, 01, | To enable Open/Close reports.
Enter fill field| 99| To exit programming mode.
Enable Keyswitch Zone and Status Output:
Keypad Display | Keypad Entry | Action Description |
---|---|---|
Disarmed | 4140,8,00 | To enter programming mode. |
Program mode | *15, 1 | To assign keyswitch to partition 1 (zone 07). |
Confirmation of arming ding | *40, 1 | To enable Open/Close reports for |
Keyswitch.
Normally closed or EOLR| 94, 94| Press 94 until “200” is shown in the lower
right corner.
Alt Program Mode| 20, 1| To configure pin 5 on 17 connector to follow
Keyswitch RED behavior.
Enter fill field| 99| Press 99 a couple of times until you exit programming
mode.
Programming an Alpha Keypad Address
Keypad Display | Keypad Entry | Action Description |
---|---|---|
DISARMED | 4140,8,00 | To enter Programming Mode. |
Program Mode | #93 | To go to “Menu Mode” |
Zone Prog. ? | 0 … 1 | Press 0 until “Device Prog.” is shown. Press 1 to enter. |
Device Address
01-30, 00=Quit| 21| To enter Address 21
21 Device Type| 1| To select Alpha Keypad Console
21 Console Part.| 1| To assign the Alpha Keypad Console to Partition 1
21 Sound Option| | Press to exit from Device Address 21 .
Device Address
01-30, 00=Quit| 22 | To enter Address 22
Note: This Address is optional — if 2s partition is used
22 Device Type| 1| To select Alpha Keypad Console
22 Console Part.| | To assign the Alpha Keypad Console to Partition 2
22 Sound Option| | Press to exit from Device Address 22 .
Device Address
01-30, 00=Quit| 00| To exit the Device Address menu.
Quit Menu Mode ? 1=YES 0=NO| 1| To exit Menu Mode.
Program Mode| *99| To exit Programming Mode
| | Note : The Vista 50P supports up to 8 Partitions.
You will need to repeat the programming steps for Device Addresses 23…28
according to the number of partitions.
Switching from Keyswitch to Keybus
- Wire the device to the panel as described on the respective wiring schemeabove.
- Use the Sync with Panel feature from the Settings menu of the Uplink mobileapp.
The device will apply the new configuration automatically.
NOTE 2: When switching the wiring of the device, make sure that the
device is not powered on.
NOTE 3: When synchronizing or disabling and enabling the Arming/Disarming
feature from the mobile application, make sure:
- the device is powered and connected to cellular network;
- the panel is not in programming menu/mode.
After enabling the Arming/Disarming feature it may take up to 1 minute for the device to apply the new configuration.