LG ARNU053TRD4 Multi VTM Four Way 2 x 2 Ceiling Cassette
INSTRUCTION MANUAL
ARNU053TRD4
Multi V™ Four-Way 2′ x 2′ Ceiling Cassette
5,500 Btu/h Indoor Unit
OVERVIEW
(Keep this distance between the bottom surface of body and Ceiling Surface)
No. | Part Name | Description |
---|---|---|
12 | Outside Air Intake Hole | Knock-out type |
11 | Flexible Drain Hose | Supplied with product |
10 | Decoration Corner Display Cover | Supplied with panel |
9 | Decoration Corner Cover | Supplied with panel |
8 | Decoration Panel (Accessory) | PT-0AGWO |
7 | Air Outlet | – |
6 | Air Intake | – |
5 | Wired remote controller wire routing hole | – |
4 | Power and Communication cable routing hole | – |
3 | Drain Pipe Connection | – |
2 | Liquid Pipe Connection | – |
1 | Vapor Pipe Connection | – |
SYMBOLS
Note:
1. Unit should be installed in compliance with the installation manual.
2. Unit should be grounded in accordance with the local regulations or
applicable national codes.
3. All electrical components and materials to be supplied from the site must
comply with the local regulations or international codes.
Performance:
Cooling Capacity (Btu/h)1 | 5,500 |
---|---|
Heating Capacity (Btu/h)1 | 6,100 |
L/M/H Power Input at Factory Default (W) | 11/12/13 |
Rated capacity is certified under AHRI Standard 1230. Ratings are subject to
change without notice. Current
certified ratings are available at
www.ahridirectory.org.
Electrical:
Power Supply (V/Hz/Ø) | 208-230/60/1 |
---|---|
Rated Amps | 0.2 |
Piping:
Refrigerant
Liquid Line (in., O.D.): 1/4 Flare
Vapor Line (in., O.D.): 1/2 Flare
Condensate
Condensate Line (in., I.D.): 1
Factory Installed Pump2; Yes
Controls Features:
• Auto changeover (Heat Recovery only)
• Auto operation
• Auto restart
• Dual thermistor control
• Dual setpoint control
• Timer (on/off)
• Weekly schedule
• Auto direction/ swing (up/down)
• Swirl wind (alternating vanes)
• Fan speed control
• Jet cool (fast cooling)
• Filter life display
• Multiple auxiliary heater applications
• Child lock
• Group control
• High ceiling
• Hot start
• Self diagnostics
• External on/off control
• Wi-Fi compatible
• Auto fan
• Leak detection
Required Accessories:
- Panel (24-13/32″ x 24-13/32″) – PT-QAGW0
Optional Accessories:
- Ventilation Flange ‐ PTVK430
- Wireless Remote Controller – PWLSSB21H
- MultiSITE™ CRC2 Controller ‐ PREMTBVC2
- MultiSITE CRC2+ Controller ‐ PREMTBVC3
- MultiSITE CRC2+Z Controller ‐ PREMTBVC4
- Simple Remote Controller – PREMTC00U
- Standard III Remote Controller (White Housing) – PREMTB100
- Standard III Remote Controller (Black Housing) – PREMTBB10
- Deluxe Remote Controller – PREMTA201
- Remote Temperature Button Sensor ‐ ZRTBS01
- Simple Dry Contact (1 contact, 24 VAC external power) ‐ PDRYCB100
- Dry Contact for Third Party Thermostat5 ‐ PDRYCB320
- Dry Contact for Economizer ‐ PDRYCB400
- Auxiliary Heater Kit5 ‐ PRARH1
- Wi-Fi Module – PWFMDD200
Entering Mixed Air:
Cooling Maximum1 (°F WB): 76
Heating Minimum (°F DB): 59
Unit Data:
Refrigerant Type | R410A |
---|---|
Refrigerant Control | EEV |
Sound Pressure dB(A) (H/M/L)3 | 29 / 27 / 26 |
Sound Power dB(A) (H)4 | 46 |
Standard Filter Type | Washable |
Unit Net Weight (lbs.) | 29 |
Unit Shipping Weight (lbs.) | 34 |
Panel Net Weight (lbs.) | 7 |
Panel Shipping Weight (lbs.) | 11 |
Fan:
Type | Turbo |
---|---|
Quantity | 1 |
Motor/Drive | Brushless Digitally Controlled/Direct |
Motor Quantity | 1 |
Air Flow Rate H/M/L (CFM) | 265 / 247 / 212 |
Notes:
1. See Engineering Manual for sensible and latent capacities.
2. Maximum lift is 27-9/16 inches from bottom of unit.
3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard
3745.
4. Sound Power levels are tested in a reverberation chamber under ISO
Standard 3741.
5. If a Third-Party Dry Contact and an LG internal heater or an LG Auxiliary
Heater Kit is installed, supplemental heat capability cannot be controlled by
the Third-Party Thermostat.
6. Communication cable between (main) outdoor unit to indoor units / heat
recovery units to be 18 AWG, 2-conductor, twisted, stranded, shielded. Ensure
the communication cable shield is properly grounded to the (main) outdoor unit
chassis only. DO NOT ground the outdoor unit to indoor units / heat recovery
units communication cable at any other point. Wiring must comply with all
applicable local and national codes.
7. Power wiring is field provided, and must comply with the applicable local
and national codes.
8. This unit comes with a dry nitrogen charge.
9. All capacities are net with a combination ratio between 95 – 105%.
10. Must follow installation instructions in the applicable LG installation
manual.
Specifications
-
Model: ARNU053TRD4
-
Product Name: Multi V™ Four-Way 2′ x 2′
Ceiling Cassette -
Cooling Capacity: 5,500 Btu/h
-
Heating Capacity: 6,100 Btu/h
-
Power Input: 11 / 12 / 13 W (L/M/H)
-
Electrical: 208-230V, 60Hz, 1 phase
-
Refrigerant: R410A
-
Sound Pressure Level: 29 / 27 / 26 dB(A)
(H/M/L) -
Sound Power Level: 46 dB(A) (H)
-
Fan Air Flow Rate: 265 / 247 / 212 CFM
(H/M/L)
Installation
- Ensure the unit is securely mounted on the ceiling following the manufacturer’s guidelines.
- Connect the refrigerant liquid and vapor lines as specified in the manual.
- Install the required accessories such as the panel for optimal performance.
Operation
- Power on the unit and select the desired mode (cooling or heating).
- Adjust the temperature and fan speed using the provided controls.
- Maintain the unit by cleaning or replacing filters regularly.
Maintenance
- Regularly clean the unit and ensure proper drainage of condensate.
- Schedule professional maintenance checks at least once a year.
FAQ
Q: Can I install additional heating elements to supplement heat?
A: If a Third-Party Dry Contact and an LG internal heater or an LG Auxiliary Heater Kit is installed, supplemental heat capability cannot be controlled by the Third-Party Thermostat.
Q: How do I ensure proper communication cable installation?
A: The communication cable between outdoor units and indoor units/heat recovery units should be 18 AWG, 2-conductor, twisted, stranded, shielded. Ensure proper grounding of the communication cable shield to the outdoor unit chassis only.
For a complete list of available accessories, contact your LG representative.