KAUWOX 3000W Solar Wind Power Pure Sine Wave Inverter User Manual
- May 15, 2024
- KAUWOX
Table of Contents
- KAUWOX 3000W Solar Wind Power Pure Sine Wave Inverter
- Use Required Reading
- Preface
- Product characteristics
- Product application
- Panel Description ( 3000W 48V)
- LED Display
- Protective function
- Installation requirements
- Wiring requirements
- Product Specification
- Frequently asked questions and solutions
- Quality Assurance Card
- Maintenance log
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KAUWOX 3000W Solar Wind Power Pure Sine Wave Inverter
Pure sine wave inverter
At a glance, multi-function LCD liquid crystal display
Use Required Reading
Lite version
- This machine has no reverse connection function, battery positive and negative lines can not be connected back, otherwise it will damage the inverter.
- There are four 16-square models for the use of two red and two together, two black and in, together. You can’t use one alone. Otherwise the current is not enough to carry the high power.
- 2V6000(3000), 12V7000(3500), 12V8000(4000),
- 4V10000(5000) ,24V12000(6000)models with four 16-square lines.
- When the INVERTER is not in use, please turn off the inverter switch, so as not to affect the life of the internal components, loss of battery power.
- 12V high voltage protection voltage is 15V, 24V high voltage protection voltage is 29V, 48V high voltage protection voltage is 57V. Do not exceed the voltage, or the inverter will be high-voltage protection, do not work.
- if you want to extend the lead between the battery inverter to be thickened, such as 10 square lines to use 20 square lines. Otherwise, the current can not afford high power.
- battery is how many volts must use how many volts inverter, if 12 V battery must use 12 inverter 24 V battery must use 24 inverter 48 V battery must use 48 inverter. otherwise it will damage the inverter. Remember! !
- the larger the battery number, the greater the power used. The power of the battery is small.
- Smart Fan has 2 boot modes
- The inside temperature reaches 45 intelligent fan starts.
- If high power is used, the intelligent fan turns straight and the low power does not turn.
Please read the instructions carefully before use. This manual refers to the graphics and text for reference only, in kind prevail!
Preface
Respected users:
First of all, thank you for choosing our pure sine wave inverter products. All
our products have been through strict production control and quality control
and accurate testing and certification, all factory products meet the national
standards. Users can buy and use! Thank you for buying our products again!
Matters needing attention
- The installation and commissioning of the equipment shall be carried out by professional electrical maintenance personnel familiar with the structure and operation hazards of the device.
- Failure to comply with this precaution may cause physical injury.
- Do not connect this equipment to the civil power distribution box, such as home lines.
- The inverter should be away from water, avoid water droplets on the machine or gradually above, do not use wet hand plug or unplug.
- If the inverter is in a cool environment, the appropriate temperature should be -20 degrees Celsius -50 degrees Celsius, avoiding direct sunlight and hot air vents.
- Inverters should be kept away from flammable substances, or where flammable gases are accumulated.
- After long-term use, the inverter will heat, so avoid close to the heat-sensitive substances.
- Ensure smooth ventilation and good heat dissipation.
- High pressure danger, please do not open this machine.
- Use the right type of wire to avoid fuse because of excessive inverter current.
- Make sure the inverter connects the correct battery, otherwise it will fuse the fuse of the inverter. Turn off the switch when the machine is not in use.
- Please turn off the switch and clean with a dry cloth before cleaning. Do not use wet cloth or cleaning agent.
Product characteristics
The inverter adopts the SPWM technology of MCU micro-processing control, pure sine wave output and pure waveform. The unique dyna -mic current loop control technology ensures the reliable operation of the inverter. Strong load adaptability, including inductive load, capacitive load, resistive load, mixed load. Strong overload and impact resistance. With input overvoltage, under voltage, overload, overheating, output short circuit and other perfect protection functions. Sinusoidal inverter adopts LCD liquid crystal display mode, the state is clear at a glance. Stable performance, safe and reliable, long service life.
Product application
- Power tools: disk saw, drill, grinder, grinder, buffer, weeding machine and trimmer, air compressor
- Home entertainment electronics: television, cassette recorders, video game consoles, audio, musical instruments, satellite equipment
- Industrial equipment: cloud server, face recognition server, intelligent manufacturing robot, emergency system
- Household appliances: vacuum cleaners, fans, fluorescent lamps and incandescent lamps, razors, sewing machines
- Office equipment: computers, printers, monitors, fax machines, scanners
- Kitchen appliances: coffee maker, blender, ice marker, toaster
Panel Description ( 3000W 48V)
LED Display
Protective function
- Low pressure alarm: buzzer with 1 Hz clearance 2 sound alarm.
- Low pressure protection: buzzer with 1 Hz clearance 3 sound continuous alarm.
- Overpressure protection: buzzer with 1 Hz clearance 4 alarm.
- Overheat protection :80±5, overheat protection buzzer 1 Hz gap 5 alarm.
- Overload protection: overload protection 10 S automatic turn off output 5 S automatic recovery, three consecutive automatic lock.
- Short circuit protection: Output Short Circuit Protection ls shutdown lock.
Installation requirements
- Inverter installation with reference to local power requirements, the installation site must be dry, clean and well ventilated.
- Working temperature :-30’C to 40’C
- Storage conditions :-l0’C to 50’C
- Relative humidity :0-95%, no condensation
- Cooling: Forced ventilation
Wiring requirements
Try to get the battery close to the inverter. The following battery line configuration requirements.
Inverter Power | Input Voltage | Input 50cm |
---|---|---|
soow | 12V/24V | 6 squared |
soow | 48V | 1 squared |
1000W | 12V | 10 squared |
1000W | 24V | 6 squared |
1000W | 48V | 2.5 squared |
2000W | 12V | 16 squared |
2000W | 24V | 10 squared |
2000W | 48V | 6 squared |
3000W | 12V | 32 squared |
3000W | 24V | 16 squared |
3000W | 48V | 10 squared |
5ooow | 24V | 32 squared |
5ooow | 48V | 16 squared |
Note: The longer the distance, the thicker the line.
Product Specification
Actual power | 500W | 1000W | 2000W | 3000W | 5000W |
---|---|---|---|---|---|
Display mode | Digital display | Digital display | LCD display | LCD display | LCD |
display
Input Voltage| 12V/24V/48V DC
Input Range| 12Vdc(10-15),24Vdc(20-29},48Vdc(40-57)
Low pressure protection| 12V(10.0V±O.l),24V(20.0V±D.l),48V(40.0V±O.l)
Overpressure protection| 12V(15.0V ±0.3),24V{ 29.0V± 0.3),48V(57.OV ± D.3)
Overload protection| SOOW>115¼| 1000W>115%| 2000W>115%| 3000W>115¼| 6000W>115%
Output voltage| IIOV/220Vac| 110V/220Vac| llOVAC/22DVac| 110V/220Vac|
110V/220Vac
Outpulfrequenc1| SOHz/GOHz| SOHz/GOHz| 50Hz/60Hz| 50Hz/60Hz| 50Hz/60Hz
Output wave forrr| Pure sine wave| Pure sine wave| Pure sine wave| Pure sine
wave| Pure sine wave
Overheat protection| 80°±5′| 80’±5′| 80°±5°| 80°±5′| 80°±5°
Waveform THO| 3%| 3%| 0%| 3%| 3%
Conversion efficiency| 90%| 90%| 90%| 90%| 90%
Cooling mode| Built-in Air Cooling| Built-in Air Cooling| Built-in Air
Cooling| Built-in Air Cooling| Built-in Air Cooling
Contour dimension| 1a.2•s·13cm| 2s.2•s•13cm| 28.5’1S’Bcm| 34•22•9,m| 4G•22•9cm
Product weigh1| 1.1kg| 1.6kg| 2.85kg| 5.1kg| 6.5kg
Frequently asked questions and solutions
-
outside interference
The inverter may be disturbed by some strong electromagnetic waves in use, such as nearby motors, power converters, strong magnetic fields, etc. -
The inverter has no reaction
-
The battery and inverter are not connected and reconnected.
-
The pole of the battery is reversed and the fuse is fused. Replace fuse.
-
Low output voltage
-
Overload, load current exceeds nominal current, turn off partial load and restart.
-
The input voltage is too low. Ensure that the input voltage is within the nominal voltage range.
-
Low Voltage Alarm
-
The battery is dead and needs to be charged.
-
Battery voltage is too low or poor contact, recharge, check battery terminals or clean terminals with dry cloth.
-
Inverter without output
-
Battery voltage is too low, recharge or replace battery.
-
The load current is too high, turn off part of the load and restart the inverter.
-
Inverter overtemperature protection. Let the inverter cool down for a while and put it in a ventilated place.
-
The inverter failed to start and restarted.
-
Terminal connection, fuse, replace fuse.
-
The inverter does not work
-
Check the power switch, fuse and battery connection or smoke.
Quality Assurance Card
- Pure sine wave inverter must be strictly checked before leaving the factory to ensure good quality. We assure you that the machines listed in the card have good performance and complete parts
- One year free warranty, as follows:
- (-)During the one-year warranty period for the purchase of the machine. if any damage or failure occurs, the machine will be provided free of charge to repair and replace the parts, and the damaged parts will be returned to our company.
- (=)The warranty period will automatically expire if the machines specified in this guarantee card are in the following circumstances.
- Change of company trademark;
- Damage caused by faulty operation, negligent use and force majeure;
- The company’s technical personnel without authorization to repair, modify or alter. remove machine number or seal:
- Do not install according to the installation instructions provided by the original factory.
( )Please keep this card properly and present this certificate and purchase receipt (invoice) to technician at repair time.
User information sheet
User units | Contact Person |
---|---|
User address | Contact number |
Distribution Unit | Postcode |
Product model | Local number |
Purchase time | Handling Personnel |
Maintenance log
Dat e| Type of maintenance| S ummary| Maintenance man| User
signature
---|---|---|---|---
| |
| | | |
| | | |
| | | |
Note: pleas e fill in the user information, copy one copy and seal 1\ and send it back 10 our marketing department for filing.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>