Specifications :

  • Module Lengths: 4ft, 6ft, 8ft
  • Tools Required: 4FT Module w/o endcaps, 6FT Module w/o endcaps, 8FT Module w/o endcaps

Product Usage Instructions

  1. Utility Box and Cover Plate Installation:
  2. Install utility box and cover plate.
  3. Strain relief.
  4. Wall Mount Bracket Installation:
  5. Plan wall mount bracket locations for 4ft, 6ft, or 8ft modules.
  6. Install wall mount brackets based on required number (2 for 4ft, 3 for 6ft or 8ft).
  7. Fixture Installation:
  8. Determine power feed location and install the utility box parallel with the fixture.
  9. Complete electrical connections at the box with the supplied power cord.
  10. Crimp supplied strain relief onto power cord insulation.
  11. Attach the cover using supplied painted hardware.
  12. Fixture Engagement:
  13. Feed the power cord through the access hole at the back of the fixture.
  14. With two people, raise the fixture into position and engage it on hooks located on top of brackets.
  15. Let the fixture rotate down into position.
  16. Endcap Installation:
  17. Insert the foam gasket onto the fixture end.
  18. Fasten the gasket in place using the supplied plastic rivet.
  19. Install LEFT or RIGHT endcap using supplied screws.

FAQ:

  • Q: How many brackets are required for each module length?
    A: Each 4ft fixture requires two brackets, and each 6ft or 8ft fixture requires 3 brackets.

  • Q: What tools are needed for installation?
    A: Tools required include the 4FT Module w/o endcaps, 6FT Module w/o endcaps, and 8FT Module w/o endcaps.

System Overview

These instructions review how to install FloatPlane wall mount fixtures. 4ft, 6ft and 8ft modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphics below show the components required to install a typical run of FloatPlane wall mount fixtures.

IMPORTANT : Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation. FloatPlane-4ft-Wall-Mount-
Fixtures-fig- \(1\)

Tools Required:

  • Medium Flat blade Screwdriver
  • Medium Phillips Screwdriver
  • 3/8” Nut driver
  • 5/16” Nut Driver

Module Lengths

  • FloatPlane wall mount fixtures come in 4ft, 6ft and 8ft modules.
  • Overall module lengths are shown below.
  • Add 9/16” for each EDGE endcap or 1” for each CURVE endcap.

FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(2\)

ATTENTION: Install in accordance with national and local building and electrical codes.

Installation Instructions

  1. Determine power feed location and install 2”x4” utility box (supplied by others) parallel with fixture. Complete electrical connections at box with supplied power cord. Crimp supplied strain relief onto power cord insulation (recommend Heyco Tool PN0019(R12). Attach cover using supplied painted hardware.

  2. Determine wall mount bracket locations based on the allowable distance from fixture ends to brackets, and also factoring in site conditions (location of structural members).
    Each 4FT fixture requires two brackets, and each 6 or 8 FT fixture require 3 brackets.

  3. Install mount brackets to wall structure using appropriate fasteners (BY OTHERS). Note bottom of installed fixture will sit approx. 3/8” below bottom edge of bracket.
    Bottom edge of wall bracket to be located flush with bottom edge of cover plate.

  4. POWER LOCATIONS : Prior to engaging fixture on mounting brackets, feed installed power cord through one of the power access holes at the back of fixture.
    With 2 people, raise fixture into position and engage it on hooks located on tops of brackets. Then let the fixture rotate down into position. FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(3\)

  5. At power feed location on fixture. Insert a medium size flat blade screwdriver into slots on access panel.

  6. Twist the screwdriver and the tab on the access panel will POP UP. Repeat on the other tab on the access panel. Open the wire access panel.

  7. Crimp supplied strain relief onto power cord insulation (recommend Heyco Tool PN0019(R12). Complete necessary electrical connections (by others) in compliance with local codes. Push the wires and connectors back down into the wire compartment when complete. FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(4\)

  8. Insert the foam gasket onto the fixture end. Using the supplied plastic rivet, fasten the gasket in place so it doesn’t move during endcap installation. Install LEFT or RIGHT endcap using supplied screws. Align the fixture housing to endcap for best aesthetic before final tightening.

  9. Ensure the electrical connectors are tucked inside the wire cavity. Push down on the lid while simultaneously twisting the flat blade screwdriver, the panel tab will lock into place. Repeat at the other screwdriver slot location.

  10. LEVEL: Using 5-16” nut driver, level fixture by adjusting the Tilt screw.
    LOCK: Lock the fixture to wall bracket assemblies by tightening the Lock screw.

  11. Insert the foam gasket onto the mounted fixture end. Using the supplied plastic rivet, fasten the gasket in place so it doesn’t move during fixture joining.
    Note the joining fixture requires its own mount brackets (2pcs if a 4FT, 3pcs if 6/8 FT) FloatPlane-4ft-Wall-Mount-Fixtures-fig-
\(5\)

  12. Ensure both fixtures are horizontal and mounted at the same height. Snug joining nuts using 3/8” nut driver, align the fixture housings for best aesthetic before final tightening. Complete necessary electrical connections in compliance with local codes. Close all wire access panels (step 9) when complete.

  13. LEVEL: Using 5-16” nut driver, level fixture by adjusting the Tilt screw.
    LOCK: Lock the fixture to wall bracket assemblies by tightening the Lock screw. FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(6\)

ADDITIONAL INFORMATION

  • FloatPlane Fixtures available with a factory installed, perforated 75% down reflector. For best optical performance, reflector must be installed as shown, SHINY SIDE facing UP. Note down reflector is installed on top of clear acrylic upper diffuser.
  • FloatPlane Fixtures available with a factory installed, solid 100% down reflector (shown as hatched lines). For best optical performance, reflector must be installed SHINY SIDE facing UP. Note down reflector is installed on top of clear acrylic upper diffuser. FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(7\)
  • If the fixture is mishandled during installation, a shadow may appear in the luminous window. This is caused by the upper diffuser being pushed below the LED.
  • Insert finger underneath the upper diffuser and gently pry the panel free along the length.
  • Re-install the upper diffuser (SHINY SIDE facing DOWN). If applicable, re-install optional 75 or 100% downlight reflectors on top of diffuser in correct orientation. FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(8\)

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Sensor in Rows

Single Sensor Controlling Whole Row

  1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.
    Note :
    A maximum of 8 drivers can be wired to 8 sensors; confirm fixture driver count with factory.FloatPlane-4ft-Wall-Mount-Fixtures-fig-
\(9\) Multiple Sensors Controlling Separates Zones in a Row

  2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
    Notes :

  3. A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.

  4. Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(10\)

Sensor Spacing

  • For correct operation, sensor should be placed a minimum distance of 8ft apart.
  • Wireless sensor should be placed no further than 40ft apart for good wireless signal connection.

FloatPlane-4ft-Wall-Mount-Fixtures-fig- \(1\)

Important Consideration When Using Sensor in a Row

  • For fixtures with wireless sensors (CS, SB or RA options):
    • DO NOT connect fixture purple and brown (or purple & grey/pink) control wires to an external dimming switch.
    • Fixture mains wiring should not be connected to a circuit with an external on/off switch.
    • For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
    • For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage:
Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire. FloatPlane-4ft-Wall-Mount-Fixtures-fig-
\(2\)

Daylight Sensor

  • The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:
    • Minimum distance from the window ≥ 2ft (0.6m).
    • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.
  • As a guideline the formula 0.72 X H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

The detection area for the movement sensor can be roughly divided into two parts;

  • Minor movements (person moving ≤ 3ft/s or 0.9m/s).
  • Major movements (person moving ≥ 3ft/s or 0.9m/s).

Photosensor spatial response

ATTENTION: Install in accordance with national and local building and electrical codes.

© 2019 Signify Holding. All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the copyright owner. Phone: 604.888.6811 Signify North America Corporation. 400 Crossing Blvd, Suite 600 Bridgewater, NI 08807. Telephone: 855-486-2216 Web: ledalite.com/products Revision D Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 253. Telephone: 800-668-9008