MFL BAR 9 LED Stage Wash Light Bar User Manual
- May 15, 2024
- MFL
Table of Contents
USER MANUAL
BAR 9 LED Stage Wash Light Bar
Please read the manual carefully before us
CAUTION
DO NOT OPEN THE HOUSING SHOCK HAZARD
Please read this manual carefully before operating this product.
Installation and operating instructions:
- Plugged into a grounded power outlet .
- Install the equipment in a well-ventilated place at least 50cm from any surface, and ensure that the ventilation slots are not blocked.
- Disconnect the equipment from the power supply before any operation.
- The ambient temperature should not exceed 40°C, and the maximum ambient temperature is 45°C. Don’t operate the device at higher temperatures.
- The equipment should be stopped immediately, if a fault occurs, and do not repair the equipment by yourself. Improper maintenance can result in damage and malfunction. Contact technical support for repair approval. Only the same accessories can be used with the original parts, and make sure the power cord is not blocked or damaged.
- Do not expose your eyes to light sources, which can be a sign of a seizure in sensitive people.
- The lamps are only used for decoration and not suitable for ordinary household lighting.
- Replacing the fuse: Unplug the device from the power supply, remove the fuse holder from its original position with a screwdriver, take out the burnt fuse, replace the fuse with the same characteristics, then rerotate the screw, and connect the device to the power supply superior.
- WARNING: Stop using it if the fuse is still blowing after being replaced. Please contact customer support for further instructions, continued use may cause serious damage.
- Fix the equipment with the screw holes on the bracket to ensure that the equipment is firmly fixed to prevent vibration and movement during operation, and always check whether the structure of the equipment is strong enough to withstand equipment that is at least ten times.
- The equipment must be fixed by professionals in places that elders and children cannot reach, and no one can pass under or over the pedestrian crossing.
- End-of-life of the product: This sign indicates that this product should not be thrown into household waste in European Community countries and that waste should be recycled to support the sustainable recycling of resources in order to protect the environment and human health Utilize. If you need to recycle used electrical appliances, please go to an electrical appliance collection center or contact the dealer where you purchased the product to ensure the ecological recycling of the product.
- Before cleaning the device, disconnect it from the power source if connected. Do not use harsh cleaners. Wipe off dust or dirt from the product with a clean cloth. We are not responsible for damage caused by incorrect handling, improper use or wear and tear.
- We reserve the right to make technical modifications.
Technical parameters:
Voltage: AC90-220V, 50-60HZ
Light source: 10pcs 4in1 LED lamp beads
Channel: 4/6/9/40/42CH
Control mode:DMX512,Sound Activated, master-slave, auto.
- Key button description MENU: Function key UP: Plus key DOWN:Minus key ENTER: Confirm key
Digital tube display menu description
NO.| content| scale|
Function and description
---|---|---|---
1| A001| 001-512| The DMX512 address setting
2| 9CH| 4/6/9/40/42| Channel mode setting
3| R255| 000 – 255| Red dimming, from dark to bright
4| G255| 000 – 255| Green dimming, from dark to bright
5| B255| 000 – 255| Blue dimming, from dark to bright
6| W255| 000 – 255| White dimming, from dark to bright
7| F000| 005 – 255| Total strobe, from slow to fast
8| CL01| 01 – 08| red, green, blue, white, yellow, purple, cyan, RGBW
9| EF01| 01 – 20| UP to switch the effect| Press ENTER to set the speed
SP01-SP15
10| SU01| 01 – 06| Sound mode| Press ENTER to set the sensitivity SE01- SE15
Channel description
Channel 4 (Full lamp)
Channel
| **** function|
**** explain
---|---|---
CH 1| 000-255| R red dimming, from dark to bright
CH 2| 000-255| G Green dimming, from dark to bright
CH 3| 000-255| B Blue dimming, from dark to bright
CH 4| 000-255| W White dimming, from dark to bright
Channel 6 (Full lamp)
Channel| function|
explain
---|---|---
CH1| 000-255| Total dimming, from dark to bright
CH 2| 005-255| Total strobe, from slow to fast
CH 3| 000-255| R red dimming, from dark to bright
CH 4| 000-255| G Green dimming, from dark to bright
CH 5| 000-255| B Blue dimming, from dark to bright
CH 6| 000-255| W White dimming, from dark to bright
9channel mode (Basic Function)
channel| value|
function declaration
---|---|---
CH1| 000-255| Total dimming, from dark to bright
CH 2| 005-255| Total strobe, from slow to fast
CH 3| 000-009| Perform the (CH 6-9 ) RGBW static dimming
010-019| Static color, CH4 Select (red, green, blue, white, yellow, purple,
cyan, RGBW)
020-029| Breathing effect, CH5 Select color
030-039| Jump change effect
040-049| Gradient change effect
050-059| Pulse change effect, CH5 Select color
060-069| Autorun effect-1, CH5 Select color(cycle autorun)
070-079| Autorun effect-2, CH5 Select color
080-089| Autorun effect-3, CH5 Select color
090-099| Autorun effect-4, CH5 Select color
| 100-109| Autorun effect-5, CH5 Select color
---|---|---
110-119| Autorun effect-6, CH5 Select color
120-129| Autorun effect-7, CH5 Select color
130-139| Autorun effect-8, CH5 Select color
140-149| Autorun effect-9, CH5 Select color
150-159| Autorun effect-10, CH5 Select color
160-169| Autorun effect-11, CH5 Select color
170-179| Autorun effect-12, CH5 Select color
180-189| Autorun effect-13, CH5 Select color
190-199| Autorun effect-14, CH5 Select color
200-209| Autorun effect-15, CH5 Select color
210-229| Autorun effect-16, CH5 Select color (8 full color effects)
230-233| Sound mode 1, CH5 Select color
234-237| Sound mode 2, CH5 Select color
…| …
246-249| Sound mode 5, CH5 Select color
250-255| Sound mode 6, CH5 Select color
CH 4| 000-255| Static color mode: red, green, blue, white, yellow, purple,
cyan, RGBW. Autorun effect: adjustment speed, from slow to fast . Sound mode:
adjustment sensitivity, from low to high (The highest sensitivity is the
sensitivity set by the menu) .
CH 5| 000-031| Default color
032-063| Red, CH3 Manual color selection
064-095| Green, CH3 Manual color selection
096-127| Blue, CH3 Manual color selection
128-159| Yellow, CH3 Manual color selection
160-191| Purple, CH3 Manual color selection
192-223| Cyan, CH3 Manual color selection
224-255| White, CH3 Manual color selection
CH 6| 000-255| R red dimming, from dark to bright
CH 7| 000-255| G Green dimming, from dark to bright
CH 8| 000-255| B Blue dimming, from dark to bright
CH 9| 000-255| W White dimming, from dark to bright
40 Channel (point control)
channel
| value|
function declaration
---|---|---
CH 1| 000-255| R1 red dimming, from dark to bright
CH 2| 000-255| G1 green dimming, from dark to bright
CH 3| 000-255| B1 blue dimming, from dark to bright
CH 4| 000-255| W1 white dimming, from dark to bright
…| …| …
…| …| …
CH 37| 000-255| R10 red dimming, from dark to bright
CH 38| 000-255| G10 green dimming, from dark to bright
CH 39| 000-255| B10 blue dimming, from dark to bright
CH 40| 000-255| W10 white dimming, from dark to bright
42 Channel (point control)
channel
| value|
function declaration
---|---|---
CH1| 000-255| Total dimming, from dark to bright
CH 2| 005-255| Total strobe, from slow to fast
CH 3| 000-255| R1 red dimming, from dark to bright
CH 4| 000-255| G1 green dimming, from dark to bright
CH 5| 000-255| B1 blue dimming, from dark to bright
CH 6| 000-255| W1 white dimming, from dark to bright
…| …| …
…| …| …
CH 39| 000-255| R10 red dimming, from dark to bright
CH 40| 000-255| G10 green dimming, from dark to bright
CH 41| 000-255| B10 blue dimming, from dark to bright
CH 42| 000-255| W10 white dimming, from dark to bright
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>