Entatial HY316 WIFI Digital Heating Thermostat User Manual
- June 17, 2024
- Entatial
Table of Contents
Entatial HY316 WIFI Digital Heating Thermostat
Many thanks for your selection of our products and services, and also for your trust and support to us.
Features
- (A) Including built-in sensor and external sensor
- (B) 0.5°C accuracy keeps the temperature within the level you set.
- (C) Children lock to prevent misoperation by children
- (D) Data memory when power is off.
- (E) Holiday mode make you enjoy more comfortable temperatures in holiday
- (F) The temperature of the external sensor can be checked
Product Specifications
- Power: 90-240Vac 50/60Hz
- Range of temperature display: 1~70°C
- Display accuracy: 0.5°C
- Insulating condition: Normal environment
- Probe sensor: NTC(10k)1%
- Running program: Set per 1 week as a cycle
- Contact capacity: 3A/(WW);16A/(WE)
- Output: Switch relay
- Limit temperature range: 1~70°C
- Installation: recessed type (in the wall)
- Range of temperature adjustment: 5~35°C
- Size(mm): 868627
Wiring Diagram
(do not connect terminal “close 4” of electric valve)
Water heating and gas wall-hung boiler heating, no contact wiring
diagram,(disconnection when electric valve close)
Note : 5&6 connect with gas boiler,3&4 connect with N and L line. If
normally closed thermal actuator, then connect with 1&3, If normally open the
thermal actuator, then connect with 2&3
Displays
Description of icon
Operation key
Program mode setting
5+2 (factory default),6+1 and 7 models 6 times period setting for user choose.
In the advanced options choose model of you need, under power on state, long
press button for 3-5 seconds enter into programming mode setting, then short
press button choose: hour,minute, time period, and press down and up to adjust
data, finished setting, about 10 seconds will automatic save and exist.
The optimum comfort temperature is 18℃-22℃.
Advanced option A
NO | Setting Options | Data Setting Function | Factory Default |
---|---|---|---|
A1 | Measure Temperature Calibration | -9-+9℃(Displayed temperature | |
value) | as | the | corrected |
A2
| Start/stop working temperature difference setting| ****
0.5-2.5℃
| ****
1℃
A3
| High temperature protection temperature difference setting| ****
1-9°C
| ****
2°C
A4
| ****
Sensor type
| N1:Internal sensor (high-temperature protection close)
N2:External sensor (high-temperature protection close)
N3:Internal sensor control
temperature, external sensor limit temperature (external sensor detects the temperature is higher than the highest temperature of external sensor, thermostat will Close relay, turn off load)
| N1
A5| Child lock setting| 0:half lock 1:full lock| 0
A6
| High-temperature protection for external sensor| 20°C-70°C
When setting temp =20°C, , if press will display 【 — 】 , cancel high temperature protection
| ****
45°C
A7
| Low-temperature protection| 1-10°C
When setting temp = 10℃, if press will display 【 — 】 , cancel low temperature protection
| ****
5°C
A8 | Setting temperature minimum limit | 1-10°C | 5°C |
---|---|---|---|
A9 | Setting temperature maximum limit | 20-70°C | 35°C |
AA
| Descaling function| 0: Disable descaling function
1: Enable descaling function
| 0
AB
| Power on/off state memory after electricity cut| 0:Thermostat on/off with memory whenel ectrify
1:Thermostat off when electrify
2:Thermostat on when electrify
| 0
AC
|
Program mode type
| 0: 5+2
1: 6+1
2: 7
|
0
AD| Window function triggers temperature| 10-20°C,setting temperature is 10°C,decrease
it ,will display【–】,then canceled this function
| —
AE| Window function running time| 10-20min| 10
AF| Restore factory defaults| Display Ao , long press key to whole
show|
Return difference : limit valve of external sensor is 45℃ for factory default (A6), value of external sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will remind high temperature production alarm. If temperature decline to 43℃relay continue to work and heating alarm will be relieved. (it can be operated, only when room temperature is lower than setting temperature )
Sensor fault display: please choose correct working way of built-in and external sensor, if choose wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. The thermostat will stop heating until the fault is eliminated
Warranty: We offer the warranty of 24 months, from the sales day. The products of our company can have a lifetime warranty, if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale service.
Installation diagram:
Documents / Resources
|
Entatial HY316 WIFI Digital Heating
Thermostat
[pdf] User Manual
HY316 WIFI Digital Heating Thermostat, HY316, WIFI Digital Heating Thermostat,
Digital Heating Thermostat, Heating Thermostat
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>