Entatial HY316 WIFI Digital Heating Thermostat User Manual

June 17, 2024
Entatial

Entatial HY316 WIFI Digital Heating Thermostat

Entatial HY316 WIFI Digital Heating Thermostat

Many thanks for your selection of our products and services, and also for your trust and support to us.

Features

  • (A) Including built-in sensor and external sensor
  • (B) 0.5°C accuracy keeps the temperature within the level you set.
  • (C) Children lock to prevent misoperation by children
  • (D) Data memory when power is off.
  • (E) Holiday mode make you enjoy more comfortable temperatures in holiday
  • (F) The temperature of the external sensor can be checked

Product Specifications

  • Power: 90-240Vac 50/60Hz
  • Range of temperature display: 1~70°C
  • Display accuracy: 0.5°C
  • Insulating condition: Normal environment
  • Probe sensor: NTC(10k)1%
  • Running program: Set per 1 week as a cycle
  • Contact capacity: 3A/(WW);16A/(WE)
  • Output: Switch relay
  • Limit temperature range: 1~70°C
  • Installation: recessed type (in the wall)
  • Range of temperature adjustment: 5~35°C
  • Size(mm): 868627

Wiring DiagramEntatial HY316 WIFI Digital Heating Thermostat
1

(do not connect terminal “close 4” of electric valve)

Entatial HY316 WIFI Digital Heating Thermostat 2

Water heating and gas wall-hung boiler heating, no contact wiring diagram,(disconnection when electric valve close)
Note : 5&6 connect with gas boiler,3&4 connect with N and L line. If normally closed thermal actuator, then connect with 1&3, If normally open the thermal actuator, then connect with 2&3

Displays

Description of icon

Entatial HY316 WIFI Digital Heating Thermostat 4

Operation key

Entatial HY316 WIFI Digital Heating Thermostat 5

Program mode setting
5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced options choose model of you need, under power on state, long press button for 3-5 seconds enter into programming mode setting, then short press button choose: hour,minute, time period, and press down and up to adjust data, finished setting, about 10 seconds will automatic save and exist.

Entatial HY316 WIFI Digital Heating Thermostat 6

The optimum comfort temperature is 18℃-22℃.

Advanced option A

NO Setting Options Data Setting Function Factory Default
A1 Measure Temperature Calibration -9-+9℃(Displayed temperature
value) as the corrected

A2

| Start/stop working temperature difference setting| ****

0.5-2.5℃

| ****

1℃


A3

| High temperature protection temperature difference setting| ****

1-9°C

| ****

2°C






A4

| ****




Sensor type

| N1:Internal sensor (high-temperature protection close)

N2:External sensor (high-temperature protection close)

N3:Internal sensor control

temperature, external sensor limit temperature (external sensor detects the temperature is higher than the highest temperature of external sensor, thermostat will Close relay, turn off load)

| N1
A5| Child lock setting| 0:half lock 1:full lock| 0



A6

| High-temperature protection for external sensor| 20°C-70°C

When setting temp =20°C, , if press                      will display , cancel high temperature protection

| ****

45°C


A7

| Low-temperature protection| 1-10°C

When setting temp = 10℃, if press           will display , cancel low temperature protection

| ****

5°C

A8 Setting temperature minimum limit 1-10°C 5°C
A9 Setting temperature maximum limit 20-70°C 35°C

AA

| Descaling function| 0: Disable descaling function

1: Enable descaling function

| 0

AB

| Power on/off state memory after electricity cut| 0:Thermostat on/off with memory whenel ectrify

1:Thermostat  off  when  electrify

2:Thermostat  on  when  electrify

| 0

AC

|

Program mode type

| 0: 5+2

1: 6+1

2: 7

|

0

AD| Window function triggers temperature| 10-20°C,setting temperature is 10°C,decrease

it ,will display【–】,then canceled this function

| —
AE| Window function running time| 10-20min| 10
AF| Restore factory defaults| Display Ao , long press  key to whole show|

Return difference : limit valve of external sensor is 45℃ for factory default (A6), value of external sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will remind high temperature production alarm. If temperature decline to 43℃relay continue to work and heating alarm will be relieved. (it can be operated, only when room temperature is lower than setting temperature )

Sensor fault display: please choose correct working way of built-in and external sensor, if choose wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. The thermostat will stop heating until the fault is eliminated

Warranty: We offer the warranty of 24 months, from the sales day. The products of our company can have a lifetime warranty, if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale service.

Installation diagram:

Documents / Resources

| Entatial HY316 WIFI Digital Heating Thermostat [pdf] User Manual
HY316 WIFI Digital Heating Thermostat, HY316, WIFI Digital Heating Thermostat, Digital Heating Thermostat, Heating Thermostat
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals