Honeywell Home 33-00618_B C-Wire Adapter Installation Guide

June 17, 2024
Honeywell Home

Honeywell Home 33-00618_B C-Wire Adapter

Honeywell Home 33-00618_B C-Wire Adapter

Overview

This product provides a C wire (common wire) to power a thermostat. Only install if you do not have a C wire available to connect to your thermostat.

ZONING CONTROL PANEL CHECK
For zoned systems, install the C Wire Adapter between the thermostat and the zoning panel, NOT between the zoning panel and HVAC equipment.

BEFORE
Overview

AFTER
Overview

Installation Instruction

  1. Turn the power off at the breaker box or control switch for your HVAC* system.

Overview

  1. *Heating, ventilation, and air conditioning
    Remove your old thermostat from the wall plate.
    Installation Instruction
    Do not remove any wires at this time!

  2. Take a picture of the wiring.
    Ensure the terminal labels and wires are in the image. You may need to reference the picture later.
    Installation Instruction

  3. Confirm that you do not have a wire in the C terminal. If you have a wire in the C terminal, then you do not need this product.
    Look for an unused wire. If you have an unused wire, then you do not need this product. Connect one end of that wire to C terminal at the HVAC and the other to C terminal at new thermostat.

  • The C wire (common) might be labeled as B rather than C on certain thermostats.
    Installation Instruction
    Symbol Go to your HVAC system. It may be located in your attic, crawl space or basement.

    1. Open HVAC system’s cover to reveal the control board.
      Installation Instruction

    2. Take a picture of the wires on the control board.
      Ensure the terminal labels and wires are in the image. You may need to reference the picture later.

  • O or B terminal may also be used.
    Installation Instruction

    1. Use stickers to label the following connected wires:

      • G
      • R or Rc
      • W or W1
      • Y or **Y1
        * Not all systems will have a W or W1-wire. On a heat pump application, the wire coming from O/B on the old thermostat would match to either O or B at equipment rather than W.
        ****
        If multiple wires are connected to a terminal, only label the the wire running to your thermostat.
        Installation Instruction
    2. Disconnect ONLY the wires that you just labelled:

      • G

      • R or Rc

      • W or W1

      • Y or Y1
        * Do NOT disconnect wires that you did not label.
        * If multiple wires are connected to a terminal, only remove the the wire running to your thermostat.
        On a heat pump application, the wire coming from O/B on the old thermostat would match to either O or B at equipment rather than W.
        Installation Instruction

    3. Insert the wires you just disconnected into the C-Wire Adapter terminals.
      Installation Instruction
      Installation Instruction
      This will convert the G and Y-wires into C and K-wires.

    4. Take a picture of the wires you inserted into the C-Wire Adapter.
      Ensure the terminal labels and wires are in the image.
      You may need to reference the picture later.
      Installation Instruction

    5. Connect the wires from the “Equipment” labelled side of the C-Wire Adapter to the matching terminals on the control board.

  • If there are separate wires to W and O, leave the W and O wires attached at HVAC and do not connect them to the C-Wire Adapter.
    Installation Instruction

    1. CHECKPOINT
      Your C-Wire Adapter should now be installed between your thermostat wiring and the control board.
      Installation Instruction

    2. Before mounting, check to make sure surface is clean enough to ensure good adhesion.
      Attach the C-Wire Adapter to the inside wall of the furnace using the magnet on the back of the C-Wire Adapter.
      Note: Earlier versions of this product had an adhesive pad and mount rather than magnet.
      Installation Instruction

    3. Close the HVAC system’s cover.
      Leave the power off.
      Installation Instruction
      Symbol Go back to your thermostat.

    4. Label your now converted wires as shown.
      Installation Instruction

The wires you label C and K are the wires you inserted into the C and K-terminals in step 9.

  1. Label ALL of the remaining wires according to their terminals.
  • O/B terminal may also be used.
    Installation Instruction

    1. Confirm you have labelled ALL of your wiring.
      Disconnect the wires from the old wall plate.
  • O/B terminal may also be used.
    Installation Instruction

    1. Refer to your new thermostat’s installation guide for detailed instructions to complete the following tasks below.
      Installation Instruction
      A Remove the old wall plate and mount the new one.
      Installation Instruction
      B Wire the new thermostat.
      Refer to the labels you applied when inserting the wires.
      When done wiring, you should have wires in the C and K-terminals.
      You should not have wires in the Y or G-terminals.
      Installation Instruction
      C Complete your new thermostat’s installation by attaching the thermostat to the wall plate, restoring the power, and configuring the thermostat.

Customer Support

Parts

www.resideo.com
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
33-00618—03 SA Rev. 05-23 | Printed in United States
© 2023 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
The Honeywell Home trademark is used under license from Honeywell International, Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Honeywell Home User Manuals

Related Manuals