This user manual contains important information regarding the operation of your smart smoke and CO alarm listener. Ensure you read this user manual fully before installing and operating the listener. If you are installing this device for use by others, you must leave this manual (or a copy of it) with the end user.
Introduction
This device is intended to work with smoke/CO alarms that meet the UL standards and last 10 years or less, however it does not detect fire, smoke, or carbon monoxide. The smoke and CO alarm listener sends you real-time mobile notifications whenever it hears alarms from the nearby existing smoke or CO alarms in your home.
Product Overview
Package Contents
Device Setup
Download the X-Sense Home Security App
To download the X-Sense Home Security App, scan the QR code or search for “JC- Sense Home Security” in the Apple App Store or Google Play Store. Sign up with a valid email address. If you already have an account, make sure the app is updated to the latest version.
Note: Make sure your smartphone supports iOs 11 and higher, or Android 8.0 and higher.
Before connecting devices, make sure that
- You know your Wi-Fi network name and password.
- You are connecting your device using a 2.4 GHz Wi-Fi network (incompatible with 5 GHz Wi-Fi network).
- Make sure the Bluetooth on your phone is turned on.
Note: When the device is configured via Wi-Fi, make sure your mobile phone and device are as close to the router as possible, which can speed up device configuration.
Connect the Smoke and Carbon Monoxide Alarm Listener to the Base Station
The Smoke and Carbon Monoxide Alarm Listener can be connected to the base
station through the wireless network. When the listener is connected to the
base station, you will receive push notifications wherever you are to stay
informed of the device status.
Note: Before adding devices to the system, make sure the base station has been successfully added to the app.
- Tap “ “, and select “Smoke and CO Alarm Listeners” in the product list. Then, tap “Nexr to enter the pairing page.
- Enter a name for the listener. Then select the room in which it is installed. Then tap “Next.’
- Remove the back cover from the device and install the battery. Ensure battery polarities are matched correctly. Then tap “Next.’
- Follow the prompts on the page by quickly pressing the test button twice on the device until the LED flashes blue rapidly, indicating that the device is waiting to connect to the Wi-Fi.
- Tap “Next” to add the device. You will hear “Ready to add the device.’
- After successfully connected, you will hear “Device added” and the “Device added” page will appear. Then, the app page will go to “Ready to Install.’ Follow the instructions to complete the installation. Now, you can find the listener in the device list.
- If you want to add multiple devices into the system, please repeat the above steps.
NOTE: If you fail to add the listener to the network within 60 seconds, the device will automatically exit the network configuration. To re-enter the network configuration, you need to repeat the above steps.
Installation Method
Gather the necessary items before installation:
Package Contents:
Installation Notes
Find a location for your listener mounting bracket within 2-6 in (5-15 cm) of a smoke/CO alarm, making sure the arrow on the bracket points to your existing smoke/CO alarm. The sensor hole of the listener should face the buzzer of the smoke/CO alarm for best results.
NOTE
- Keep the distance between the smoke/CO detector and listener no closer than 2 in (5 cm).
- Keep the distance between the smoke/CO detector and listener no more than 6 in (15 cm).
Installation Instructions
- Once you have decided the mounting location, mark two screw holes on the wall or ceiling according to the holes on the mounting bracket, then drill the two screw holes to a depth of 1.2 in (30 mm) using a 01/4 in (6.0 mm) drill bit.
- Insert the anchor plugs and screw in the mounting bracket using the provided screws.
- Attach the listener to the mounting bracket by turning clockwise to lock the device.
Note: The sensor is housed in the small hole on the side of the listener. Please do not poke it, as this may result in damage.
Signal Reception Test
After the listener is attached to the mounting bracket, tap *Nexr and you will
go to the HSignal Reception Test page. The signal reception test ensures that
the listener can receive alarm signals from your smoke/CO alarm.
-
Press the smoke or CO alarm’s tesVsilence button. The listener will flash red and an in-app message “Alarms Signal Received will appear below the page when the listener receives an alarm signal.
Note: If the listener does not hear your alarm, it cannot monitor your alarm. This is possibly because you didn’t press the smoke/CO alarm’s test/silence button, or the smoke/CO alarm is too old and needs to be replaced. -
The signal reception test lasts 3 minutes. Tap the Test Cancelation button or press the button on the side of the listener to cancel the test.
Installation Is Completed
Your listener has been installed and now the listener is hearing your smoke/CO
alarm.
Testing yoursmoke/CO alarm may trigger the listener (including the device’s
test after battery replacement).
To avoid false alarms, press the button on the side of the listener or enable
the signal reception test in the app before testing your smoke/CO alarm, then
press the test/silence button on the smoke/CO alarm.
Wrthout Using the App
You can start the listener’s signal reception test without using the app,
which will facilitate the monthly test of your smoke/CO alarms.
Step 1: Press the button on the side of the listener to start the reception test. The listener will flash red quickly.
Step 2: Press the smoke/CO alarm’s test/silence button. If the listener receives alarm signals, the LED indicator will flash red and you will receive a push notification.
The signal reception test lasts 3 minutes. Press the button on the side of the listener to cancel the test.
Battery Replacement
- To replace the battery, detach the listener from the mounting bracket by twisting it counterclockwise.
- Remove the batteries, then install new batteries matching the correct polarity markings.
- Test the device, then mount the listener onto the mounting bracket by twisting clockwise to lock the device.
Technical Specifications
Specifications of Alarm Listener
LED Indicator of Listener
Troubleshooting
Environmental Protection
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with Local Authority or retailer for recycling advice.
Manufacturer and Sevice Information
X-Sense Innovations Co., Ltd.
Address: B4-503, Kexing Science Park 15 Keyuan Road, Shenzhen, 518057, CHINA
Email: support@x-sense.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>