X-SENSE XSO1-W Wireless Interlinked Smoke Alarm User Manual

June 6, 2024
X-SENSE

X-SENSE logo Wireless Interlinked Smoke Alarm
User Manual

This user manual contains important information regarding the operation of your X-sense Pro smoke alarm. Ensure you read this user manual fully before installing and operating the alarm. If you are installing this smoke alarm for use by others, you must leave this manual (or a copy of it) with the end-user.

Package Contents

X SENSE XSO1 W Wireless Interlinked Smoke Alarm -
package

Safety Information

IMPORTANT

  1. DANGERS, WARNINGS, AND CAUTIONS ALERT YOU TO IMPORTANT OPERATING INSTRUCTIONS OR TO POTENTIALLY HAZARDOUS SITUATIONS. PAY SPECIAL ATTENTION TO THESE SITUATIONS.
  2. THIS ALARM IS NOT INTENDED TO ALERT HEARING-IMPAIRED INDIVIDUALS. THE USE OF ALCOHOL OR DRUGS MAY ALSO IMPAIR ONE’S ABILITY TO HEAR THE SMOKE ALARM.
  3. FIRES IN CHIMNEYS, WALLS, ROOFS, DIFFERENT LEVELS, OR BEHIND CLOSED DOORS MIGHT NOT BE DETECTED.
  4. THIS DEVICE DOES NOT DETECT FLAMES, HEAT, CARBON MONOXIDE, OR OTHER HAZARDOUS GASES.

WARNING

  1.  NEVER IGNORE ANY ALARM. FAILURE TO RESPOND CAN RESULT IN SERIOUS INJURY OR DEATH.
  2. THE SILENCE FEATURE IS ONLY FOR YOUR CONVENIENCE AND WILL NOT CORRECT A PROBLEM. ALWAYS CHECK YOUR HOME FOR A POTENTIAL PROBLEM AFTER ANY ALARM. FAILURE TO DO SO CAN RESULT IN INJURY OR DEATH.
  3. TEST THIS SMOKE ALARM ONCE A WEEK. IF THE ALARM EVER FAILS TO TEST CORRECTLY, REPLACE IT IMMEDIATELY! IF THE ALARM CAN NOT WORK PROPERLY, IT WILL NOT ALERT YOU TO A PROBLEM.

Set up and Interconnect Wireless Alarms

All XS01-W alarms contain a built-in RF module that enables you to wirelessly connect 2 or more interlinked alarms and create an interlinked network. When one unit is triggered, all interconnected units will sound an alarm. The XS01-W wireless interlinked alarms in one multi-pack have already been interconnected, and the alarms in each multi-pack have their own independent interlinked network. If you have more than one multi-pack, you will need to connect them all to the same network. Choose one multi-pack as your base network and connect the other multi-packs to it.

How to Interconnect

  1.  Attach 2 wireless alarms onto their mounting brackets and turn clockwise to lock and activate them (see the sections on “Installation Positioning” and “Installation Method”). Make sure these alarms power on.
  2. Quickly press the Test/Silence button on one of the 2 units 4 times; it will beep once and the red LED will flash slowly, indicating it has entered pairing mode and is waiting for a new unit to be added. Quickly press the Test/Silence button on the other unit twice; it will beep once and the red LED will flash rapidly, indicating it is searching for a device to connect to.
  3. After the search is successful and an interconnected group is created, both units will beep once and automatically exit the interconnection mode. At this point, both units will only flash once 60 seconds, indicating they are in normal standby mode.
  4. If you want to connect a third alarm to this group, first activate a new device according to its operating instructions, then quickly press the Test/Silence button on either of the 2 previously interconnected units 4 times. This unit will beep once, and the red LED will flash slowly, indicating it is ready to add a new device to the network. Next, quickly press the Test/Silence button on the new unit twice, and the red LED will flash rapidly as it searches for a network to connect to. After the third unit successfully joins the interconnected network, both units will beep once and automatically exit the interconnection mode.
  5. If you want to connect more units, simply repeat step 4. Up to 24 alarms can be interconnected this way. To ensure that all alarms enter the same interlinked network, make sure you only work with 2 units at a time—one unit enters the pairing mode and the other unit enters the searching mode.
  6. Test the alarms according to the steps in the section “Alarm Test”.

X SENSE XSO1 W Wireless Interlinked Smoke Alarm - alam
test

NOTES

  1. The alarm will enter the searching mode or the pairing mode for 60 seconds with the red LED flashing. After 60 seconds the pairing mode will stop and you need to repeat step 2 to connect the alarms. If needed, press the Test/Silence button once while the alarm is in the searching mode or the pairing mode, and the red LED will stop flashing and the alarm will quit the pairing mode to enter normal status.
  2. Test all your wireless alarms to ensure they are interconnected before installation.
  3. A maximum of 24 wireless alarms can be interconnected on the same network.
  4. The model can only be interconnected with other X-sense Pro XS01-W wireless interlinked alarms.

How to Disconnect

Quickly press the Test/Silence button 4 times; the smoke alarm will beep once. Then, hold down the button until it beeps once more to disconnect. After disconnecting, it can be reconnected to the same network, or added to a new network.
NOTE: The X-sense Pro XS01-W wireless interlinked alarms in one multi- pack have already been interconnected. To create a new network, you will first need to disconnect each alarm individually in this multi-pack to avoid having them all join the same network.

Alarm Test

The alarm must be properly attached to the mounting bracket before it can be tested; otherwise, it will not turn on. Be sure to test your alarms when you turn them on for the first time, or when the group configuration has changed. In addition to the weekly tests you should perform, it is recommended to test the alarm after returning from a long trip or vacation. If your XS01-W is interconnected to other wireless alarms, we recommend that every individual alarm is tested during the weekly test.

| Testa single alarm| Test all interconnected smoke alarms
---|---|---
Action| Press the test/silence button.| Hold down the test/silence button.
Indication| •The alarm will sound in 3 short quick beeps.
•The red LED will flash once every second during the audible signal.
•After testing, the alarm will automatically enter standby mode.| •The initiating smoke alarm will beep continuously with the red LED flashing.
•Other interconnected smoke alarms in the network will receive the signal after 5 seconds, and they will beep continuously with the red LED flashing. Release the test/silence button and all the smoke alarms will stop testing.
•The alarm testing should be completed within 3 minutes.
•After testing, the units will automatically enter standby mode.

NOTE: The test function accurately tests the alarm’s smoke sensing circuit without the need to test with smoke. If your smoke alarm fails to give an audible test signal, please refer immediately to the troubleshooting guide at the end of this manual. Never use an open flame to test this device.

Installation Positioning

X SENSE XSO1 W Wireless Interlinked Smoke Alarm -
positiioning

NOTE: If a smoke alarm is installed in a kitchen, ensure it has an accessible silence button, and install it as far away from the stove and sink as possible to avoid false alarms.

  1. Prioritize the installation of an alarm in the bedroom and walkways, and make sure you can hear the alarm from all sleeping areas. In a home with several bedrooms, install an alarm in every bedroom. If you install only one smoke alarm in your home, install the alarm near to all bedrooms where possible, and not in a basement or furnace room.
  2. Install an alarm above the stairway and on every floor of the house.
  3. Smoke, heat, and anything burning will spread horizontally after rising to the ceiling, so install the alarm in the middle of the ceiling where possible. Ensure that the alarm is installed at a minimum distance away from the corner.
  4. If an alarm cannot be installed in the middle of a ceiling, install it at a distance of 50 cm (20 in) away from the corners of the room.
  5. If an alarm is installed onto a wall, a distance of 10-30 cm (4-12 in) should be kept below the ceiling.
  6. If the length of a room or hall is beyond 900 cm (30 ft), several alarms should be installed in the same room.
  7. When the wall or ceiling is angled, the alarm needs to be installed within 90 cm (3 ft) of the highest wall or ceiling point (measured horizontally) in the room.
  8. In multi-level houses or apartments, install at least one wireless smoke alarm on each level and keep them installed in a straight vertical line (see diagram) with as few obstacles between each of the interconnected alarms as possible to ensure optimal signal transmission.

X SENSE XSO1 W Wireless Interlinked Smoke Alarm - fig1

Locations to Avoid:

  1. Near large metal surfaces and/or bundles of wire.
  2. Near fluorescent lights, amateur radios, electrical equipment, or other devices that may transmit an RF signal, as electronic “noise” may cause nuisance alarms.

WARNING

  1. THIS ALARM SHOULD BE INSTALLED BY A COMPETENT PERSON.
  2. ALARMS SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION, USE, AND MAINTENANCE OF FUEL-BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS.
  3. TO PREVENT INJURY, THIS DEVICE SHOULD BE SECURELY ATTACHED TO THE CEILING OR WALL IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
  4. BATTERIES SHOULD NOT BE EXPOSED TO EXCESSIVE HEAT SUCH AS DIRECT SUNLIGHT, FIRE, ETC.

Installation Method

NOTE: Before installation, it is recommended to test the interconnected alarms in the rooms where you intend to install them to ensure that they are within transmission range and that nothing will interfere with their communication.

  1. Use the mounting bracket to mark the screw holes on the ceiling or the wall.
  2. Drill holes at the two marks using an appropriately-sized drill bit. Insert the anchor plugs and screw the mounting bracket using the screws provided.
  3. Attach the alarm to the mounting bracket and turn clockwise to lock the alarm.
  4. Test the alarm according to the steps in the section “Alarm Test”.

X SENSE XSO1 W Wireless Interlinked Smoke Alarm - fig2

LED Indicator and Audible Alarm

Status LED indicator Audible alarm Action
Standby Mode Red LED flashes once every 60 seconds. None
Alarm Mode Red LED flashes once every flashes a second. Short quick beeps
Test Mode Single Smoke Alarm Red LED flashes once every second. 3 short
quick beeps Press the test/silence button once.
All interconnected smoke alarms in the network Red LED flashes once every
second. Continuous beeping until you release
the test/silence button Hold down the test/silence

button.
Silence Mode| Red LED flashes once every 5 seconds.| None|
---|---|---|---
Low Battery| Red LED flashes once every 60 seconds.| 1 beep every 60 seconds| Each alarm gives an independent warning.
Malfunction| Red LED flashes twice every 40 seconds.| 2 beeps every 40 seconds| Each alarm gives an independent warning.

Silence Mode

If you press the silence button during an alarm state, the unit will be in silent mode for 9 minutes. During the silence mode, the red LED will flash once every 5 seconds. The alarm will enter normal mode after 9 minutes.
NOTES

  • You can silence all interconnected units by pressing the Test/Silence button on one of the units. If one unit is still alarming, it is the initiating unit (the unit that detected danger); to silence all interlinked units, you must also press the Test/Silence button on the initiating unit
  • While interconnected, the initiating unit cannot be triggered again during the 9-minute silence duration. However, all other interconnected units can be triggered again if they detect danger during the silence mode.

Technical Specifications

Power Supply 10-year sealed lithium battery (non-replaceable)
Sensor Type Photoelectric
Safety Standard EN 14604:2005+AC:2008
Coverage Area 20-40 m2 (215-430 sq. ft)
Operating Temperature 4-38°C (40-100°F)
Operating Relative Humidity 5 85%(non-condensing)
Alarm Loudness z 85 dB at 3 m @ 3.2 ± 0.3 kHz pulsing alarm
Silence Duration About 9 minutes
Operating Frequency 868 MHz

Maximum Number
of Interconnected Units| 24 wireless units
(only compatible with X-sense Pro wireless alarms)
Transmission Range| Over 250 m in the open air

NOTES

  1. Battery life is calculated on the current ratings in the standby mode with weekly testings. If its operation mode changes to an alarming condition, the battery life will be decreased accordingly.
  2. The smoke alarm functions between 4-38°C (40-100°F). Prolonged exposure to temperatures outside of this range can reduce battery life and affect accuracy. We do not recommend operating the device outside of this range.

Maintenance

To keep your smoke alarm in good working order, follow these simple steps:

  1. Verify the unit’s alarm sound and indicator are working properly by testing the unit once a week.
  2. As a minimum, your smoke alarm should be cleaned once every 3 months: Remove the unit from the ceiling and clean the alarm cover and vents with your vacuum cleaner fitted with the soft brush attachment to remove dust and dirt.
  3. Never use detergents or other solvents to clean the unit.
  4. Avoid spraying air fresheners, hair spray or other aerosols near the alarm.
  5. Do not paint the unit. Paint will seal the vents and interfere with the sensor’s ability to detect fire.
  6. Never attempt to disassemble the unit or clean inside. Doing so will void your warranty.
  7. When removed, place the smoke alarm back in its proper location as soon as possible, to assure continuous protection from fire.
  8. When household cleaning supplies or similar contaminants are used, the area should be ventilated.

Troubleshooting

PROBLEM SOLUTION
Your smoke alarm does not sound during testing. •Please check whether the

alarm is properly attached to the mounting bracket
•Make sure you push the test button firmly.
•Check the installation positioning. The wireless signal might be blocked or out of range.
False alarms are triggered intermittently or when residents are cooking, taking showers, etc.| •Check the location of your smoke alarm (see Installation Positioning”).
•Clean the smoke alarm (see “Maintenances).
Red LED fl ashes and the alarm sounds one beep every 60 seconds.| The battery is low. Replace the device immediately, as the battery is sealed inside the device and can’t be replaced.
Red LED fl ashes and the alarm sounds two beeps every 40 seconds.| The alarm is malfunctioning. Please clean your smoke alarm and see if it is working normally. If not, replace the device immediately.

Environmental Protection

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with the Local Authority or retailer for recycling advice.

Manufacturer and Service Information

X-sense Innovations Co., Ltd. Address: B4-503, Kexing Science Park, 15 Keyuan Road, Shenzhen, 518057, CHINA

Importer

X-Sense Europe B.V. Parellaan 2H, 2132 WS Hoofddorp, the Netherlands

Warranty

Thank you for purchasing our product. X-sense Pro provides a 5-year worry-free guarantee from the date of purchase. If you have any questions, please feel free to contact the dealers or distributors in your region. They will get back to you within 1-3 working days.

X-Sense Innovations Co., Ltd.
Conforms to EN 14604:2005+AC:2008
Phone Number: +86 755-2267-0560
Importer
X-Sense Europe B.V.
Parellaan 21-f, 2132 WS Hoofddorp, the Netherlands

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>