Gaslow 3.9kg or 4.5kg Gas Cylinder Locker Kit Instructions
- June 17, 2024
- Gaslow
Table of Contents
Gaslow 3.9kg or 4.5kg Gas Cylinder Locker Kit
KIT CONTENTS
- 1X GAS LOCKER
- 1X CAMPING GAZ REGULATOR
- 1X LPG STICKER
- 1X GAS BOTTLE BRACKET AND STRAP
- 1X BULKHEAD NOZZLE
- 1X DROP VENT
- 1X 0.5M 8MM ORANGE GAS HOSE
- 1X 2M 8MM COPPER GAS PIPE
- 2X JUBILEE CLIPS
- 2X NUTS
- 2X BOLTS
YOU WILL NEED
- 54mm HOLESAW FOR DROP VENT
- 13mm DRILL BIT FOR BULKHEAD NOZZLE
- 4mm DRILL BIT FOR BOLTS
We recommend that you use a gas detector once installed to make sure that you have no leaks.
FITTING INSTRUCTIONS
-
In the top of the locker, drill a 13MM hole into the locker. The ideal place is towards the rear of the locker (roughly 10-20mm from the back edge), so that the fitting and pipe are closer to the side of your van.
-
However, this can be placed wherever is best suited for your layout.
-
Remove the nut and olive from the top of the bulkhead nozzle and set aside. Remove the flat nut also and place the bulkhead nozzle in the hole, with the threaded end (for copper pipe) facing up and out of the locker.
-
Replace the flat nut and tighten it to secure it to the bulkhead nozzle of the locker.
-
In the bottom of the locker, drill a 54mm hole into the locker. The ideal place is close to the front edge so your gas bottle does not obstruct the vent.
-
Place the drop vent into this hole with the collar facing down, going out of the locker.
-
On the back wall of the gas locker use the gas bottle bracket to mark the holes for the bolts, around 115mm up from the bottom.
-
Drill the 2x 4mm holes you have just templated from the bracket. You should now have x2 holes in the back wall for the nuts and bolts used for the gas bottle bracket.
-
Thread the strap through the bracket leaving it open, with a similar length at each end. (You will close the strap when the gas bottle is in place)
-
Inside the locker, place the gas bottle bracket against the back wall and insert the bolts provided through the bracket and the back wall.
-
From the rear of the locker place the nuts on the bolts and tighten.
-
Attach the orange gas hose to the bulkhead nozzle at the top of the locker.
(TIP: Put the end of the orange gas hose in hot water for 20-30 seconds to soften it temporarily, this will allow it to easier slide onto the barbed fittings) -
Place the x2 jubilee clips onto the orange hose and connect the free end to the camping gas regulator. Then tighten the jubilee clips up over the barbed fittings.
-
From the bulkhead nozzle, place the nut and then the olive onto your 8mm copper pipe. Insert the copper pipe into the top of the bulkhead nozzle and secure it by tightening the nut onto the bulkhead nozzle.
-
Only tighten until there is a firm grip, over tightening may cause a leak.