MySmile LP221 Cordless Oral Irrigator User Manual

June 17, 2024
MySmile

MySmile LP221 Cordless Oral Irrigator User Manual

IMPORTANT SAFEGUARDS

When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING.

DANGERS:

  • To reduce the risk of electrocution
  • Do not handle the charger with wet hands.
  • Do not place the charger in or drop the charger into water or other liquid.
  • Check the charger cord for damage before the first use and during the life of the product.
  • Do not place or store product where it can fall or be pulled into a tub or sink.
  • Do not place in or drop into water or other liquid.
  • Do not reach for a product that has fallen into the water. Unplug immediately.

WARNING:

  • To reduce the risk of burns, electrocution, fire, serious injury to person
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Oral irrigators shall be used only with cold or warm water, or specific solutions as defined in the manufacturer’s instructions.
  • Children shall not play with the appliance.
  • It must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
  • The product contains non-replaceable batteries.
  • Do not plug this device into a voltage system that is different from the voltage system specified on the device or charger.
  • If the product is opened/disassembled for ANY reason, the warranty is VOID.
  • Never operate this product if it has a damaged cord or plug if it is not working properly, if it has been dropped or damaged, or dropped into water.
  • Return the product to a service center for examination and repair.
  • Do not direct water under the tongue, into the ear, nose, or other delicate areas. This product is capable of producing pressures that may cause serious damage in these areas.
  • Do not direct water into the nose or ear. The potentially deadly Bacteria may be present in some tap water or unchlorinated well water and may be fatal if directed into these areas.
  • A product should never be left unattended when plugged in.
  • Use this product only for its intended use as described in this manual.
  • Do not use attachments not recommended by the manufacturer.
  • Use this product only as indicated in these instructions or as recommended by your dental professional.
  • The appliance must be disconnected from the supply mains when removing the battery;
  • The battery must be removed from the appliance before it is scrapped;
                    • The battery is to be disposed of safely.
  • Only use tips and accessories that are recommended by MySmile
  • Do not drop or insert any foreign object into any opening on the product.
  • Keep the charging unit and cord away from heated surfaces.
  • Do not use this product outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.
  • Do not use iodine, saline (salt solution), or water-insoluble concentrated essential oils in this product. Use of these can reduce product performance and shorten the life of the product. Use of these products may void the warranty.
  • Fill the reservoir with water or other dental professional-recommended solution only.
  • Remove any oral jewelry before the use of this product.
  • Do not use it if you have an open wound on your tongue or in your mouth.
  • If your physician advised you to receive antibiotic premedication before dental procedures, you should consult your dentist before using this instrument or any other oral hygiene aid.
  • Magnetic field:  Pacemakers and similar implanted medical devices may be affected by magnets.
  • Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free of lint, hair, and the like.
  • Never use it while sleeping or drowsy.
  • Never drop or insert any object into any opening or hose.
  • Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.
  • Unplug this product before filling it. Fill (reservoir) with water only unless otherwise specified by the manufacturer. Do not overfill (or specify filling instructions).

Product Description

  1.  JetTip
  2.  Tip Rotator
  3.  OLED Display.
  4.  Power Button
  5.  Pressure “+” Button
  6. Mode Butto
  7.  Pressure ** Button
  8. Reservoir
  9. Tip Eject Button
  10.  Drain Hole
  11.  USB Charging Port
  12. Temperature Sensor
  13. Water Tube
  14. Gravity Ball Sucker
  15. UVC Light Sanitzer

Note: When first use, the water that may remain on reservoir is distiled water after
product was tested in manufacturing, no harmful to human body, please don’t worry.

GETTING STARTED

  1. Powering the Unit 1. Before using for the first time, please fuly charge the product! Be sure to use. with original USB charging cord included in package, USB end connects to DCSV 1A standard port and Type-C end plugs into charging port of the product. As image @ shown.

  2. When charging, the display will show charging lie image ( 45 hours, the display indicates completed like image

  3. Please charge the device when t’s warned “Low Power” on Display, see image(d

  4. While charging, keep the charging port dry and do not rinse the product. 5. Please place the product on your desktop verticall, not horizontall. The device

Afer fully charging

should never be covered with a wrap or towel during charging.

Inserting and Removing Tips

  1.  Insert the tip into center of the knob unti the tip clicks into place, see image (3.
  2. To remove the tip, press the tip eject button, see image ©
  3. While device is spraying water, do not press tip eject button to avoid tip popping up, cause to injury.

Operating The Product

  1. Long press the ONIOFF button for 2s, the device turns on and on standby state,the display shows battery power, water temperature, mode and pressure level.See image (7

  2. Short press “M button to switch modes, see image

  3. When the device turns on with standby state, press “+ and ~” at meanwhile toswitch temperature unit between C and * .

  4. Mode Introduction:
    Strong: Powerful spraying, for deep hard to clean stains.
    Normal: Moderate strength, daily cleaning for majority of people.
    Soft: Spray gently, for sensitve teeth, new users and children above 8 years old.
    Puise: Spray in strong-weak cycle, massage gum and for people with mildperiodontits.
    (When select mode in running process, Modes change i cycle like below)

  5. After mode selected, short press ONIOFF button to start working. Then short press ONIOFF button will pause the process, and machine stops working.

  6. Pressuire level setting: Strong, normal and soft modes all have 3 pressure level to adjust, take strong mode for an example:

  7. When power s off, long press “M” button to tum on UVC mode. UVC light is tumed on with 1205 countdown on when short press ONIFF: button. In UVC steriizing process, the display tumns to standby page when short press ONJOFF button, see below.

  8. When Sterilization completes, the display automatically turns to standby state after 10s. Or in 10s, the display directly tums to standby state if short press ONIOFF button.

  1. Long press ON/OFF button 0.5s, the device will be tumed off; While the device is on standby state without any action in 35s, it will shut off automaticaly.
  2.  For accurate temperature display, please add water to level over the scale mark where the temperature sensor probe is able to soak into water. See image/d)

Starting Cleaning Your Mouth

  1.  Hold both product body and water tank like image 0, rotate in a counter-clockwise direction, then pull the water tank down to disassemble it.

  2. Fill the water tank with lukewarm water or pure water, see image (

  3. Rotate product body and water tank meanwhile in clockwise to assemble water tank

  4. Tum on the device, select proper mode and pressure level. 5. Insert tip, diect tip at an angle of 90° to your guiine or between your teeth. Short press ONIOFF button to spray stream and move back and forth.
    Press ONIOFF button again to pause in any time if needed. See image 1213,

Warm Tips:

For those who wear denture or braces, please mainly clean between testh
For sensilive testh, please start with soft mode and then adjust modes based onpersonal circumstances.
Please don’t over tilt the device while t’s running to avoid it stops sucking water out due that gravity ball doesn’t soak into water.

After Use and Maintenance

  1. Reservoir Cleaning
  2. Use bottle brush clean up scale depositnside the water tank after detaching it, see image ®. 2. Rinse the tube and gravity ball, or use warm waer to steriize them, see image (.

Maintenance

  1. Please tum the device off after every use.
  2.  Ifthe device is not about to use for a long time, empty the remaining water, wash.the reservoir and natural ai dry it before storage.
  3. For hygiene consideration, please replace jet tip every 3 months.
  4. The device is recommended to wash with tap-water or warm water below 35°CI95°F5. Please timely clean up impurities on filtring net at the end of gravity ball

ENVIRONMENTAL PROTECTION INFORMATION

Hazardous Substances Table

This table is compiled according to SJIT 11364 standard.

Indicates that the concentration of the hazardous substance in all homogeneousmaterials for the partis below the relevant threshold of the GB/T 26572 standard.
X: Indicates that the conceniration of the hazardous substance in at least one.homogeneous materials for the part is above the relevant threshold of the GBIT 26572 standard.

Environmental Protection

The interior battery must be recycled before you throw away the appliance at the end ofis lfe, or you are able to hand itn to offical recyciing center.
Disassemble the battery only when the appliance is being disposed. f0) S i protecton of the product In normal siate is 10 years.

Read More About This Manual & Download PDF: