Oase 5500 Aquarius Fountain Set Eco User Manual

June 17, 2024
Oase

Oase logo

Aquarius Fountain Set Eco
5500, 7500, 9500

Commissioning

5500 Aquarius Fountain Set Eco

Original manual. This manual belongs with the unit and must always be passed on together with the unit.

WARNING

  • Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution.
  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.

Further instructions in a PDF format are available for download online at: www.oase.com/manual

The following additional topics are addressed in the operating manual:

  • Product features, symbols on the unit
  • Cleaning and maintenance, storage/winter-proofing, malfunction repair
  • Technical data, wear parts, spare parts, disposal

Safety information

Electrical connection

  • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
    – The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
    – For your own safety, please consult a qualified electrician.

  • Only connect the unit if the electrical data of the unit and the power supply match.

  • Only plug the unit into a correctly installed outlet.

  • The device is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.

  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).

  • Protect open plugs and sockets from moisture.

Safe operation

  • Operate the unit only when there are no people in the water.
  • The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators (ICDs). Keep a distance of at least 0.2 m between the implant and the magnet.
  • Do not use the unit, if electrical lines or the housing are damaged.
  • The supply cord cannot be replaced. If the cord is damaged, the appliance should be scrapped.
  • Do not carry or pull the unit by its power cable.
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Never carry out technical changes to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.
  • Should problems occur, please contact the authorised customer service or OASE.

Intended use

  • For pumping normal pond water for water features and fountains.
  • While adhering to the technical specifications.
  • Adherence to the permissible water quality.

The following restrictions apply to the unit:

  • Do not use in swimming ponds.
  • Never use the unit with fluids other than water.
  • Never run the unit without water.
  • Do not use for commercial or industrial purposes.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
  • Do not connect to the domestic water supply.

Product Description

Oase 5500 Aquarius Fountain Set Eco - Fig 4

Aquarius Fountain Set Eco 5500, 7500, 9500

  1. Fountain pump
  2. Telescopic extension
  3. Nozzles
  4. Transition piece with fine filter screen
  5. Flow regulator, ball joint with union nut, transition piece, sleeve, double nipple
  6. Stepped hose adapter

Installation and connection

Reassembling the unit
How to proceed:
 A

Oase 5500 Aquarius Fountain Set Eco - Fig 1

  1. Fit the sleeve, flow regulator, double nipple, union nut, ball joint and transition piece together and screw onto the pump outlet.
  2. Screw the telescopic extension with the desired nozzle onto the flow regulator.
  3. Screw the stepped hose adapter onto the flow regulator for feeding a water course if applicable.
  4. Align the telescopic extension and hand tighten the union nut on the ball joint.

Installing the unit
**
WARNING**
Severe injuries or death due to operation of this unit in a swimming pond. Defective electrical components will electrify the water with dangerous electrical voltage.

  • Never operate the unit in a swimming pond.

NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear and will require earlier replacement.

  • Thoroughly clean the pond or pool before installing the pump.
  • Install the pump at a raised level above the bottom. This reduces intake of muddy water.

How to proceed:
 B

Oase 5500 Aquarius Fountain Set Eco - Fig 2

  • Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely covered with water.

Commissioning/start-up
CAUTION
Risk of injury due to unexpected start-up. Internal monitoring functions may switch off the unit and automatically reactivate it.

  • Disconnect the power plug before carrying out any work on the unit.

NOTE
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.

  • Do not connect the unit to a dimmable power supply.

Switching ON/OFF

  • Switching on: Plug the power plug into the outlet.
    – The unit switches on immediately.

  • Switching off: Pull the power plug from the outlet.

Environmental Function Control (EFC)
When started up and then every 20 … 40 minutes the pump automatically performs a pre-programmed self-test (Environmental Function Control (EFC)). The pump detects if it is running dry / clogged or submerged. The pump shuts down automatically after 60 to 120 seconds if it runs dry/is blocked. In the event of a malfunction, disconnect the power supply and “flood the pump” or remove the obstacle. Afterwards, the unit can be restarted.

Setting the flow rate
 C
Setting the spray pattern and flow rate:

Oase 5500 Aquarius Fountain Set Eco - Fig 3

  • Adjust the flow regulator so that the nozzle produces the desired spray pattern.
  • Adjust the flow regulator to achieve the desired flow rate for the water course.

OASE GmbH
Tecklenburger Straße 161
48477 Hörstel | Germany
+49 (0) 5454 80-0
+49 (0) 5454 80-9353
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Oase User Manuals

Related Manuals