guzzle H2O 515-0000 Stealth Flex Carbon Block Filtration Instruction Manual
- June 17, 2024
- guzzle H2O
Table of Contents
- MICROBIOLOGICAL HAZARD
- PART IDENTIFICATION
- STEALTH FLEX SYSTEM LAYOUT
- STEALTH FLEX SYSTEM OVERVIEW
- MOUNTAING BRACKET INSTRUCTION
- STEALTH FLEX INSTALLATION
- STEALTH FLEX OPERATION
- SEALTH FLEX BRACKET MOUNTING PATTERN
- SEALTH FLEX WIRING DIAGRAM
- TO DISCONNECT PUSH TO CONNECT FITTINGS
- TO INSTALL PUSH TO CONNECT FITTING
- INSTALL UV UNIT IS SHOWN TO ELIMINATE TRAPED AIR POCKETS
- LED STATUS CODES
- CHANGING CARBON FILTER
- WINTERIZING
- STEALTH SYSTEM TIPS AND TROUBLE SHOOTING
- PRODUCT SPECIFICATIONS AND CAPACITIES
- CUSTOMER SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
guzzle H2O 515-0000 Stealth Flex Carbon Block Filtration
MICROBIOLOGICAL HAZARD
Human consumption of untreated water can lead to exposure to harmful
microorganisms and an increased risk of gastrointestinal illness. Operating
this filtration and purification device incorrectly increases your risk of
exposure to harmful microorganisms and increases your risk of gastrointestinal
illness. Reduce your chances of becoming sick by following the warnings and
instructions in this operator’s manuals.
Guzzle H2O products are designed to reduce unwanted bad taste & odor,
chlorine, VOCs, lead, mercury, and other contaminant particles as small as 0.5
micron in size. Guzzle H2O products are 3rd party tested in accordance with US
EPA Guidelines for Ultraviolet Disinfection to inactivate 99.99% of viruses,
protozoa, and bacteria. Guzzle H20 products do not remove toxins, heavy
metals, or treat chemically contaminated water, and will not make potable
water from sources with these contaminants. Observe all instructions and
specifications in this document. When in doubt, treated drinking water should
be tested by the user to verify its safety to consume.
UV exposure risk if used improperly
Electrical shock possible
PART IDENTIFICATION
ITEM NO>
ITEM NO. | DESCRIPTION | qty. |
---|---|---|
1 | FILTER, 0.5 MICRON CARBON BLOCK, TWIST LOCK, ASSEMBLY | 1 |
2 | TUBING, 0.375 OD, 0.25 ID, PEX. BLUE | 1 |
3 | LED UV CHAMBER, PEARL AQUA 12C, WITH FLOW SENSING SWITCH | 1 |
4 | THREAD FORMING SCREW, PHIL HEAD, NO 8, 0.75 LG, 316 SST | 4 |
5 | WOOD SCREW, PHIL HEAD, NO 10, 0.75 LG, 316 SST | 4 |
6 | MOUNTING BRACKET, FILTER, TWIST LOCK OR SLIMLINE, STEEL, POWDERCOATED | 1 |
7 | CAP, TWIST LOCK FILTER MANIFOLD, ACETAL, WHITE | 1 |
8 | CABLE ASSEMBLY, 2.1 x 5.5MM PLUG, 2-16 AWG CABLE, PLAT, 15FT LG | 1 |
9 | STRAIGHT ADAPTER, 0.375 PTC x 0.375 NTP | 2 |
10 | DECAL, DO NOT FREEZ WARING | 1 |
12 | DECAL, STEIALT SERIAL NUMBER | 2 |
14 | 0-RING, 0.949 OD, 0.755 ID, 0.907 THK, SILICONE, FOR TWIST CAP | 1 |
15 | CONNECTOR, STRAIGHT, 0.375 PTC X 0.375 PTC, ACETAL, WHITE | 1 |
16 | STRAIGHT DOPTER, .375 TUBE X .5 BARB | 2 |
17 | STRAIGHT DOPTER, .375 TUBE X .375 BARB, ACETAL | 2 |
18 | HOSE CLAMP, WORM DRIVE, .5 TO .9 ID, .5 W, .23 THK, SST | 2 |
STEALTH FLEX SYSTEM LAYOUT
NOTES
NOTE THE DIRECTION OF WATER FLOW
STEALTH FLEX SYSTEM MAY BE ARRANGED WITH IN LENGTH OF THE RIGHT OR LEFT SIDE
SEE INSTRUCTIONS FOR FOR REVERSING CARBON FILTER BRACKET PHASE 6.
WATER MUST ALWAYS FLOW TO THE CARBON FILTER BEFORE UV.
TUBE SECTION 2 MAY BE TRIMMED OR BENT TO ACCOMODATE INSTALLATION.
OR
STEALTH FLEX SYSTEM OVERVIEW
System Layout:
The Stealth Flex includes a carbon filter and a UV purification chamber. It
must be installed with the carbon filter at the water inlet, and the UV at the
outlet. See page 4. The Stealth Flex should be installed on the cold water
line between the water source, such as the pump or pressure tank. or water
line; and the point of use faucet. Ideally the Stealth should be the last
component the water passes through before the faucet.
It is optional to provide a dedicated stand alone drinking water faucet for
the Stealth Flex system. Operator preference should dictate this decision.
Considerations include a slight pressure drop associated with the carbon
filter, and if a fully isolated water purifier is required.
Mounting :
The Stealth Flex can be mounted to configure the inlet on the Right or Left side of the system. Note that the Mounting Bracket (6) must be arranged to provide the inlet to the Carbon Filter on the desired side. See instructions on Page 6 for reversing the Mounting Bracket if necessary.
Electrical Supply
The Stealth requires 12v power supply, drawing 1 amps when activated. Alternately a 12V power adapter can be used to connect to 110V.
Operation:
The Stealth Flex has a instantaneous flow sensing switch which detects water flow and immediately activates the UV. The Stealth Flex will sense that water is moving when you open the faucet. The sensor will notice a minimum of 0.3 litres per minute flow rate. LED technology allows it to instantly switch ON the UV chamber to full power and effectiveness with no warm up necessary. It draws minimal power when it is in standby mode.
MOUNTAING BRACKET INSTRUCTION
1) NOT FLOW DIRECTION FROM CARBON FILTER TO UV UNIT IT MAY BE NECESSARY TO REVERSE MOUNTING BRACKET **6.
**
2) TO REVERSE REMOVE BRACKET SCREWS 4 X4.
3) REPOSITION BRACKET 6.
STEALTH FLEX INSTALLATION
Tools required:
No 2 Philips Head Screwdriver
Tube Cutter (Optional)
General Practices
- Read all instructions before use.
- Remove the Stealth Flex from Packaging, ensure contents are complete.
- Do not power on UV without water connected and initial flushing.
- For installation location, consider ease of access for filter changes, minimum bend radii of tubing, and access to electrical connections.
- Do a quick test fit before beginning installation.
- Use appropriate connection fittings compatible with the inlet and outlet fittings.
Instructions
- Turn off water supply, and/or all pumps supplying pressure to the water system.
- Determine plumbing layout. Stealth may be mounted with inlet on the right or left hand side of the unit. See Page 4,5 and 6. Plan for adequate space for inlet and outlet plumbing to have a clean approach, and to be secured to minimize movement and vibration when installation is complete. PEX tube (1) may be trimmed using Tube Cutter, or may bend to fit irregular spaces and installations.
- Install Filter Mounting Bracket (6) to top of filter housing for Right or Left inlet. Note IN and OUT sides of filter. IN should come from water supply, and OUT should connect to PEX tube (1) and on to UV Unit (3). See Page 4 and 6.
- Remove Carbon Filter (1) and set aside.
- Holding Filter Mounting Bracket (6) in place, attach to wall with provided Wood Screws (5) using No 2 Philips Head Screwdriver. Screws are self tapping. Do not over-tighten screws, substrate material may strip if over-tight end. If mounting in a material other than wood, metal, or plastic, substitute appropriate fasteners.
- Push PEX Tube (2) into Filter OUT connection. See instructions Page 11 for using Push To Connect Fittings. Once connected, pull on the tube to tension the Push To Connect fitting to create seal.
- Remove blue clip on flow sensor. Push other end of PEX Tube (2) into Flow Sensor side of UV unit(3). Replace blue clip to secure collar.
- Select 3/8” (17) or 1/2” (16) Barbed Adapter to fit local plumbing. Supplied Barbed fittings will work with Braided PVC tube, as well as some PEX tubing. For other fittings, see Tips or consult www.guzzleh2o.com. Push barbed fittings into local plumbing, and secure with worm drive hose clamp.
- Insert stem of Barbed fittings (16 or 17) into INLET of Carbon Filter, and OUTLET of UV unit (3). See Push To Connect Fitting Instructions Page 12 & 13.
- Connect power cable cable (8) to 12V power supply. RED cable connects to positive (+) terminal. BLACK cable connects to negative (-) terminal. Connect barrel plug to underside of UV unit. Trim power cable length as necessary. See Wiring Diagram Page 11.
- Secure UV Purification Chamber (3) and PEX tube (2) as necessary to minimize movement. Note correct orientation of UV Purification Chamber (Page 14).
- Install Carbon Block Cartridge (1). Insert and turn clockwise to lock in place.
- Turn on water supply. Determine that there are NO LEAKS.
- Turn on power to UV and test operation. GREEN light indicates power is ON. BLUE light indicates UV system is ACTIVE when water flows. BLUE light should turn off when water flow stops. See Status Light Codes Page 15.
- Flush carbon fines out of new Carbon Filter. Run 3-5 gallons of water through Stealth Flex to remove carbon fines from new Carbon Filter. You will see black sediment in water as fines are removed.
- Have a drink of clean water!
STEALTH FLEX OPERATION
When power is connected to the Stealth, after startup, the green indicator LED
illuminates to indicate it is on STANDBY MODE (see page 9). In this mode, the
Stealth is ready to purify water, but has not yet activated the UV
purification chamber.
The UV purification function of the Stealth activates automatically by sensing
water flow and activating the UV purification chamber when water is moving. A
few seconds after the water stops, the Stealth turns the purification chamber
off. Water flow typically is started and stopped by using your faucet. UV
purification activity is indicated by the BLUE LED indicator light. The sensor
requires a minimum of 0.3 liters per minute of flow to activate.
LED technology allows the UV purification chamber to instantly activate and
perform at full effectiveness. The UV chamber does not require any time to
“warm up.”
The Stealth can be left on STANDBY MODE indefinitely. The UV function should
only activate when water is running.
Pulsecare:
When the UV unit is in Standby Mode, and water is not flowing, the UV unit
will periodically activate to clean the UV chamber. This prevents
microbiological pathogens from migrating through the chamber due to natural
colonization and transport. While inactive, the UV will flash for 1 second
every 30 minutes.
If system is left off for more than 12 hours, contamination from
microbiological migration is possible, and water lines should be sanitized.
SEALTH FLEX BRACKET MOUNTING PATTERN
SCALE 1:1
SEALTH FLEX WIRING DIAGRAM
BARREL PLUG 10 INTO UV UNIT
TO DISCONNECT PUSH TO CONNECT FITTINGS
1) PRESS COLLAR TO RELEASE FITTING
2) PULL FITTING OUT OF SOCKET
TO INSTALL PUSH TO CONNECT FITTING
1) INSERT TUBE INTO SOCKET
2) PULL FITTING TO ENGAGE SEAL
INSTALL UV UNIT IS SHOWN TO ELIMINATE TRAPED AIR POCKETS
LED STATUS CODES
BLUE | GREEN | MEANING | SOLUTION |
---|---|---|---|
OFF | ON | Unit is receiving adequate power; UV-C disinfection is off; water is | |
not flowing | |||
ON | ON | Unit is receiving adequate power; UV-C disinfection is active; water | |
is flowing | |||
BLINKING AT STARTUP | OFF | UV Pulse Care Enabled | |
ALTERNATE BLINKING | Thermal Error | Verify there is adequate flow through unit, |
no obstructions in unit, and water temperature meets specification
ON| FLASHING| LED Status Error| UV lamp replacement needed – contact Guzzle
H2O
CHANGING CARBON FILTER
WHEN TO CHANGING THE CARBON BLOCK FILTER
Carbon block filter cartridge (1) should be changed after 750 gallons of use. Actual capacity may vary depending upon quality of water filtered. Reduced water flow rate through filter or at the faucet is an indication that the carbon block filter element should be changed.
HOW TO CHANGE CARBON BLOCK FILTER
Shut off water pressure, and open faucet to drain and depressurize water line. Place a towel below filter canister to catch any water that may drain. Twist the carbon block filter canister (1) counter clockwise and pull. Install a new carbon block filter cartridge by inserting and turning clockwise to lock. Turn on water pressure, let water run. Run 5 gallons of water through system to dislodge and remove any loose carbon fines. Close faucet and check for leaks.
LED CHAMBER MAINTENANCE FREE
The LED UV chamber has a lifespan of 10,000 hours of activated operation. It does not need to be replaced as a maintenance item.
WINTERIZING
FREEZING TEMPERATURES CAN DAMAGE STEALTH AND CAUSE WATER SYSTEM LEAKS AND
DAMAGE
Temperatures below 32F (0C) can damage the Stealth Flex causing leaks and loss
of performance. Follow WINTERIZATION PROCEDURES to prepare Stealth for
freezing conditions.
WINTERIZATION PROCEDURES
In below freezing temperatures, water MUST BE REMOVED from the Stealth Flex or damage may occur to the UV unit and carbon filter. Follow these procedures in addition to any recommendations that may come with the rest of your water system. See diagram page 18.
- Remove carbon cartridge (1). Twist counterclockwise and pull out of socket.
- Insert Cap (7) and turn clockwise to secure and seal .
- Use air to push water out of the Stealth Flex. Open the faucet. Pump compressed air into the water system via a blowout valve and push air and water through the UV unit and out the faucet. Water should come out of open faucet. Pulse air until no more water is expelled through faucet, and water is removed from UV unit.
- Close the faucet.
ALTERNATIVELY TO THIS PROCEDURE, anti-freeze fluid may be used to protect the Stealth Flex
from freezing conditions. Remove CARBON BLOCK CARTRIDGE (1) as described on page 18 and follow manufacturer instructions for distributing food safe anti- freeze fluid throughout the system including the Stealth Flex to prevent damage from water from freezing.
FREEZING TEMPERATURES CAN DAMAGE STEALTH AND CAUSE WATER SYSTEM LEAKS AND
DAMAGE
Temperatures below 32F (0C) can damage the Stealth Flex causing leaks and loss of performance. Follow WINTERIZATION PROCEDURES to prepare Stealth for freezing conditions.
WINTERIZATION PROCEDURES
-
TURN OFF WATER PRESSURE
-
TURN ON CARBON CARTRIGE COUNTER CLOCKWISE TO UNLOCK FROM FILTER BASE
-
INSTALL FILTER CAP INSERT AND SOCKET AND TURN CLOCKWISE TO LOCK IN PLACE
-
FOLLOW INSTRUCTION TO BLOW OUT WATER SYSTEM ARE FILL WITH ANTIFREEZ SOLUTION
STEALTH SYSTEM TIPS AND TROUBLE SHOOTING
- Secure all hoses and cables connecting to the Stealth Flex. Loose and vibrating connections can lead to water leaks and faulty electrical connections.
- After replacing carbon filter cartridge with a new filter, some visible black carbon fines may be dislodged in new carbon filter. This is normal, allow approximately 5 gallons of water to pass to remove carbon fines.
- For best performance, filter and purify water as close to point of use as possible. The Stealth should be the last thing your drinking water passes through before faucet. For whole system filtration, consult Guzzle H2O.
- For installation, consider ease of access, max length and minimum bend radius of piping, electrical connections when selecting installation location. Use appropriate pipe and tubing compatible with supplied barbed fittings.
- Note that the UV unit may be attached with push to connect fittings directly to a faucet. This creates a very space saving installation.
- The carbon filter will cause a 3-5 psi pressure drop in line pressure as it filters water. This may cause automatic pressure water pumps to cycle on and off as pressure limit is reached. This is normal. Adjust pump pressure to accommodate, or consult Guzzle H2O for higher flow options.
- Stealth Flex should be installed in a protected, watertight area. It is very rugged, but not made for outdoor installation.
- There are various inlet and outlet attachments that accommodate PEX tubing, and faucet connections. Consult Guzzle H2O for options for specific plumbing connections.
- Periodically clean onboard water tanks by shock treating with bleach or chlorine. This will reduce buildup of contaminants. The carbon block filters will do an excellent job of removing any residual chlorine from cleaning efforts.
- Label carbon filter cartridge with install date to track when it is time to replace.
- A 110V power adapter is available for installations requiring connection to mains power.
- Use double sided tape to hold mounting bracket to wall to secure mounting screws.
- Replacement filters are available on a subscription basis from www.guzzleh2o.com for automatic re-order every 6 months.
FOR SUPPORT OR TECHNICAL ASSISTANCE FROM GUZZLE H2O PLEASE EMAIL US AT INFO@GUZZLEH2O.COM
PRODUCT SPECIFICATIONS AND CAPACITIES
MAXIMUM FLOW RATE; TAP WATER: 2.1 GALLONS (8.0 LITRES) / MIN
FLOW RATES AND CAPACITIES ARE FOR IDEAL CONDITIONS. FLOW RATES AND CAPACITIES MAY BE REDUCED BY CARBON BLOCK FILTER AGE, WATER QUALITY, OR WATER PRESSURE
ACTIVATED CARBON BLOCK FILTER 0.5 MICRON NOMINAL
REDUCES: NSF Particulate Class I sediment, chlorine taste and odor, VOCs, NSF 41 emerging contaminants, lead, mercury, PFAS, microplastics, turbidity, . Will not remove heavy metals or toxins
CHANGE AFTER: 750 gallons OR 6 month use, whichever comes first
LED UV-C PURIFICATION: 99.99% REDUCTION IN PROTOZOA, BACTERIAL, AND VIRUSES
Based on 3rd Party Testing to US EPA Ultraviolet Disinfection Guidance Manual
Tested and Certified by NSF International against NSF Standard 55 for
Performance, Materials and Structural Integrity
10,000 hour lifespan
MAXIMUM SYSTEM PRESSURE 120 PSI (8.3 Bar)
MINIMUM SYSTEM PRESSURE 30 PSI
SYSTEM TEMPERATURE MIN: 32F (0C) / MAX 113F (45C)
POWER DRAW ACTIVE 1 AMP
POWER DRAW STANDBY MODE 0.1 AMP
NSF LISTED AND FDA APPROVED MATERIALS
CUSTOMER SUPPORT
SCAN HERE TO FIND PARTS,
MANUALS, AND RESOURCES
FROM GUZZLE H2O
WWW.GUZZLEH2O.COM
GUZZLE H2O LLC WWW.GUZZLEH2O.COM
INFO@GUZZLEH20.COM
363 JEWETT BLVD, WHITE SALMON, WA USA
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>