dyson SV12 JN.00000 Purifier Cool Gen 1 User Manual

June 17, 2024
dyson

dyson SV12 JN.00000 Purifier Cool Gen 1

Specifications

  • Model: Dyson Purifier Cool Gen1
  • Filter Type: HEPA+Carbon
  • Continuous Monitoring: Yes
  • Auto Mode: Yes
  • Oscillation: Yes
  • Night Mode: Yes
  • Sleep Timer: Yes

Product Usage Instructions

Assembling Your Machine

  • Use both hands to lift your machine out of the box by its base.
  • Do not lift out by the loop amplifier.

Getting Started

  1. Place the remote control on top of the machine with the buttons facing down.
  2. Plug in the machine and switch it on.

Power and Continuous Monitoring:

  • Standby On/Off: Press the Standby On/Off button on your Dyson purifying fan or remote control to stop your machine.
  • It will continue to monitor the air quality.
  • Continuous Monitoring: Press and hold the Auto mode button on the remote control for 5 seconds to turn on continuous monitoring.
  • The LCD screen will indicate when it is active.

Information Menu

  • Press the Information menu button to scroll through the information being monitored by your Dyson purifying fan.
  • It displays information about particulate matter and filter levels on the LCD screen.

Auto Mode

  • To activate Auto mode, set your Dyson purifying fan to Auto mode.
  • The onboard sensors will adjust the settings according to the air quality levels.
  • The machine will pause when target air quality is reached and resume when levels drop.

FAQ:

How often should I replace the HEPA+Carbon filter?

  • The LCD screen will indicate when your filters need replacing based on the remaining filter life displayed.
  • It is recommended to replace the filter as indicated on the screen for optimal performance.

Can I turn off continuous monitoring?

  • Continuous monitoring is turned off by default but can be activated by pressing and holding the Auto mode button on the remote control.
  • It can be turned off in a similar manner or through the settings menu on the machine.
  • Front view of the Dyson Purifier Cool Gen1 fan, showing the amplifier loop and mesh filter cover, screen below the loop amplifier, and outer cover release button on the side.

Assembling your machine

  • Use both hands to lift your machine out of the box, by its base.
  • Do not lift out by the loop amplifier.

Dyson Purifier Cool Gen1

  • Supplied with a combined glass HEPA+Carbon filter.

Getting started

  • The layout of the remote control with the power button on the top left, the airflow speed toggle button in the middle left, and the oscillation button on the bottom left.
  • On the top right-hand side is the Auto mode button, then going downwards is the Night mode button and then the Information menu button at the bottom.

Power and continuous monitoring

Stand-by on/off

Continuous monitoring

  • Press the Standby on/off button on your Dyson purifying fan or remote control to stop your machine. It will continue to monitor the air quality.
  • Continuous monitoring is turned off by default. Once turned on, it will always be active until you turn it off again.
  • With continuous monitoring turned on, your Dyson purifying fan will gather particulate matter information, which is displayed on the LCD screen.

Continuous monitoring

  • Press and hold the Auto mode button on the remote control for 5 seconds to turn it on. The LCD screen will indicate when continuous monitoring is on or off.

Information menu

  • Press this button to scroll through the information being monitored by your Dyson purifying fan.
  • Information about particulate matter and filter levels is shown on the LCD screen.
  • When a particular type of pollutant causes air quality to decrease, a symbol for the pollutant will show on the LCD screen.
  • The remote control with the information button on the bottom right.
  • Indoor particulate matter – 12 seconds
    • Monitors the current particulate matter with a graph showing the last 12 seconds of data.
  • Particulate matter (PM10)
    • Larger microscopic particles up to 10 microns in size, are suspended in the air we breathe.
    • These include dust, mold, and pollen.
  • Particulate matter (PM2.5)
    • Microscopic particles up to 2.5 microns in size, are suspended in the air we breathe.
    • These include smoke, bacteria, and allergens.
  • Filters
    • The remaining filter life is shown on the LCD screen and will indicate when your filters need replacing.

Auto mode

  • Set your Dyson purifying fan to Auto mode and the on-board sensors will intelligently adjust the settings of the machine according to the air quality.
  • Air quality: your machine will pause when the target air quality has been reached, switching on again when the air quality levels drop.
  • Airflow speed: the airflow speed will increase until the target air quality has been reached.

Airflow speed

  • Press the Airflow speed button to increase and decrease the airflow speed.

Oscillation

  • Press the Oscillation button to circulate the air around the room and scroll through the oscillation settings from 0° to 350°.

Night mode and Sleep timer

  • In Night mode, your Dyson purifying fan will continue to monitor and respond to changes, but only using its quietest settings – and with its LCD screen dimmed.
  • Press the Night mode and Sleep timer button to scroll through the timer options.

Changing your HEPA+Carbon filter

  • Before changing your filter, switch off and unplug your Dyson purifying fan.
  • The remaining filter life is displayed on the screen and will indicate when your non-washable filters need replacing.
  • Press the Information button on your remote.
  • You’ll need to reset the filter life on your machine.

Dyson Purifier Cool Gen1

  • Supplied with a HEPA+Carbon filter.
  • To change your HEPA+Carbon filter, push down the buttons on either side of your machine to release the outer cover.
  • Push down on the tabs to remove the filter.
  • Push the replacement filter into the outer cover and make sure the tabs click into place.
  • Put the outer covers into position on your machine and push firmly until they both click securely into position.
  • Plug in switch your machine, and reset your filter life.
  • The air purifier fan with the filter covers open shows a HEPA plus carbon filter located in the filter covers.
  • Arrows demonstrate that the filter covers will need to be assembled onto the base of the machine.

Resetting your HEPA+Carbon filter life

  • It’s important to reset your filter life after you have replaced your filter.

Resetting your HEPA+Carbon filter life

  • Press and hold the Night mode button on your remote control.
  • The display on your machine will count down from five, the filter life will be reset and your machine is ready to use.
  • Press the Night mode and Sleep timer button on the middle right of the remote control, above the Information menu button for 5 seconds.

Looking after your machine

  • To always get the best performance from your Dyson purifying fan, it’s important to regularly clean it and check for blockages.

Cleaning your machine

  • If your machine is dusty, wipe it with a damp lint-free cloth.
  • Look for blockages in the air inlet holes on the filter and the small aperture inside the loop amplifier.
  • Use a soft brush to remove dust and debris.
  • Don’t use detergents or polishes to clean your machine.

Error codes

  • If your machine shows an error code, try turning it off and then on again. If this doesn’t clear the error code contact Dyson Customer Care.
  • For more information and support for your machine go online: www.dyson.com/support

Documents / Resources

| dyson SV12 JN.00000 Purifier Cool Gen 1 [pdf] User Manual
SV12 JN.00000 Purifier Cool Gen 1, SV12 JN.00000, Purifier Cool Gen 1, Cool Gen 1
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals