AMANA DS01E PTAC Packaged Terminal Air Conditioner Instruction Manual

June 17, 2024
Amana

AMANA-logo

AMANA DS01E PTAC Packaged Terminal Air Conditioner

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
product

Product Information

Specifications

  • Product Name : PTAC Wireless Kits (DT01G, DS01E, DD01E)
  • Manufacturer: Goodman Company, L. P.
  • Trademark : Maytag Corporation
  • Year of Manufacture: August 2010

Product Usage Instructions

Installation Precautions

Before beginning the installation, please take note of the following important instructions:

  • Ensure that wires are properly run from the thermostat location to the unit location, and from the door sensor location to the PTAC location.
  • If room numbers are to be configured, follow the designated procedure in the manual.
  • Access the front mounting screw by tilting the bottom of the front forward and lifting it slightly up and forward.
  • Detach the cabinet front from the chassis.
  • Mount the antenna as high up on the control panel as possible and as far to the right as possible, ensuring it does not interfere with the reinstallation of the PTAC.
  • Reattach peripherals to their mounted backplates.
  • Install optional security screws if desired.
  • For DT01G Kit, mark holes for screw location on the polymer room front. Remove the antenna housing and drill two 1/8″ holes where marked. Some units may already have predrilled holes in the correct location.

Antenna Installation for DT01G Kit

A DT01 antenna must be installed on the digital PTAC to allow the operation of either the DS01 remote RF thermostat or a DD01* combination PIR motion sensor and door switch. Follow these steps for antenna installation:

  1. Disconnect power to the unit by unplugging the power cord at the wall outlet or subbase, or disconnecting power at the fuse box or circuit breaker.
  2. Remove the antenna cable and route it through the opening in the bottom of the antenna housing.
  3. Prepare the DT01* antenna for mounting.
  4. Mount the antenna as high up on the control panel as possible and as far to the right as possible, ensuring it does not interfere with the reinstallation of the PTAC.

FAQ

  • Q: What precautions should I take during installation?
    • A : As a professional installer, it is important to be familiar with the product and follow all safety precautions. Thoroughly read the Instruction Manual and pay special attention to all safety warnings. It is your responsibility to install the product safely and instruct the customer on its safe use.
  • Q: Can I use existing practices instead of the precautions listed in the Installation Manual?
    • A : The precautions listed in this Installation Manual are intended to supplement existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence.

The following installation instructions are for a typical installation.
Please contact your PTAC salesperson for additional assistance and explanation prior to ordering materials or cutting openings.

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to know the product better than the customer. This includes all safety precautions and related items. Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings. Often during installation or repair it is possible to place yourself in a position that is more hazardous than when the unit is in operation.  Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use.

Safety is a matter of common sense…a matter of thinking before acting. Most dealers have a list of specific good safety practices…follow them.

The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence.

BEFORE BEGINNING INSTALLATION, PLEASE READ IMPORTANT NOTES BELOW

  • If devices are to be powered, field installed wiring will need to be run from thermostat location to unit location and from door sensor location to PTAC location and from wired magnet to sensor location.
  • If wireless platform DP01G, DP01E or DL01E are being utilized, then room numbers MUST BE CONFIGURED in the control board prior to binding wireless devices.
  • All units must have DT01G antenna for wireless devices to communicate properly. Sequence of installation:
    • 1) Mount the peripherals
    • 2) Verify operation of the door sensor
    • 3) Program room numbers
    • 4) Bind peripherals
    • 5) Reattach peripherals to their mounted backplates
    • 6) Install optional security screws
  • Installation and videos are available on our website at www.amana-ptac.com.
  • Use only one DD01E Passive Infrared Motion Sensor (PIR) door switch combination device and/or one DS01E to one DigiSmart™ PTAC unit.

Antenna Installation For DT01G Kit

A DT01 antenna must be installed on the digital PTAC to allow operation of either the DS01 remote RF thermostat or a DD01* combination PIR motion sensor and door switch.

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig1

Preparation

  1. Disconnect power to the unit by unplugging the power cord at the wall outlet or subbase, or disconnect power at the fuse box or circuit breaker.
  2. If the cabinet front is screwed to the chassis, remove the 1/4” screw (or screws). See following figure.
  3. Remove cabinet front from chassis by tilting the bot-tom of the front forward, lifting slightly up and for-ward.
  4. Mount the antenna as high up on the control panel as possible and as far to the right as possible in a location that will not interfere with the reinstallation of the PTAC polymer room front. Mark holes for screw location. Re-move antenna housing and drill two 1/8” holes where marked. Some units may have the holes already pre-drilled in the correct location.
    1. Remove antenna cable and route cable through open-ing in bottom of antenna housing.
  5. Mount antenna housing with two screws as shown in figure. (NOTE: The Amana® brand logo should be in the lower right hand corner).
  6. Plug wire harness from antenna into connector on the control board to the right of the master switch, being careful not to bend and/or break the wires when you connect the cable to the PTAC. Gently push the con-nector into place by pushing on the edge of the connec-tor with your thumb nails. Avoid pushing directly on the wires.
  7. Restore power to the PTAC unit.
  8. Reinstall the polymer room cover.

NOTE : The LED must be oriented at the top of the antenna housing (the Amana® brand logo will be on the lower right) for proper unit operation.

Thermostat Installation for DS01E Kit

NOTE : A DT01 must be installed on the digital PTAC unit for the DS01 to be operable.  Skip these steps if not installing.

  1. Select thermostat mounting location about five feet above the floor, on an inside wall, out of direct sun-light, away from sources of radiant heat (lamps, fire-places, heating and air conditioning equipment, etc.), away from windows or door to the outside, and avoid areas with poor air circulation. If the PIR in the ther-mostat is to be used with a
    • DD01* device as a 2nd mo-tion sensor, point the thermostat towards the area where you are requiring additional motion sensing.
    • Ensure location is out of the path of foot traffic where a person might accidentally bump into the thermostats and damage the device.
  2. Remove thermostat from mounting plate by pulling apart at the bottom of the thermostat about 1”, and slide thermostat up to release from the top of the mounting plate.
  3. Place thermostat mounting plate against the wall at de-sired location and mark placement of mounting holes. Make sure the UP arrow is pointing up on the mounting plate.
  4. If mounting in drywall, tap plastic anchors into wall. For other surfaces, drill a 3/16” hole.
  5. Screw mounting plate to the wall. DO NOT SNAP THER-MOSTAT INTO PLACE UNTIL AFTER BINDING PROCESS. See Binding Instructions on page 10.
  6. Install four (4) AA batteries (included) into the back of the thermostat. Terminals are marked “+” and “-” for polarity.

NOTE : Do not install thermostat on wall plate until all con-figuration settings and binding processes have been com-pleted.

WIRED POWER OPTION

  1. If the option for wired power is used, the two thermo-stat wires (20 gauge minimum field supplied) can be connected to the thermostat.
  2. Route wires through the opening in the mounting plate.
  3. Loosen set screws on wired terminal and insert wires into the opening. Tighten set screws. (See following figure for powered connection with 2 jumpers).
  4. Connect wires at PTAC unit to terminal pins C and R. The wire harness kit PWHK01C is required for this con-nection.

BATTERY CONNECTION

NOTE : For battery connection the 2 jumpers must be posi-tioned as shown above, with jumpers on the center & left pins.

POWERED CONNECTION

NOTE : For powered connection, the 2 jumpers must be positioned as shown above, with jumpers on the center & right pins.

Mounting Sensor/Door Magnet Installation for DD01E Kit

DD01E must be mounted on the top door frame as close to the door as possible in the horizontal position.

A DT01E must be installed in the PTAC unit for the DD01E to be operable.

Skip these steps if not installing.

  1. Remove motion sensor from mounting plate by pulling apart.
  2. Mount the back plate on the door trim directly above the door using the enclosed screws. (Position so the UP arrow is pointing up.) Mount the DD01E as low as pos-sible on the door frame to be as close to the moving part of the door as possible without interfering with the door opening or closing. Choose a location for mount-ing the back plate  that will provide good coverage of the PIR for motion into the room. Make sure that the DD01E will not interfere with the normal opening and closing of the door.
    • DD01E Mounting
    • DO NOT SNAP MOTION SENSOR IN PLACE UNTIL AFTER BINDING PROCESS.See Binding Instructions, page 10.

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig5

  1. Install two (2) AA batteries (included) into the back of the thermostat. Terminals are marked “+” and “-” for polarity. Do NOT put batteries into the device until AFTER the magnet location is selected to test.

WIRED MAGNET AND POWERED DOOR SENSOR OPTION

In cases where there is no top door frame, the sensor will need to be mounted on the wall next to the door. In these cases a wired magnet (a field supplied single pole single throw wired magnet) can be recessed or surface mounted and wired to the door sensor. The magnet will be a recessed style magnet with wired switch. The wires for the sensor (20 gauge field supplied) in the magnet will need to be run during construction. Two wires will be run from the door sensor location to the PTAC unit; the remaining two wires will be run from the magnet location to the sensor location. The door sensor has four (4) terminal locations for wired power and/or wired magnets. The two (2) terminals closest to the binding button are for wired magnet and the top two (2) terminals are for wired power.
Run the magnet wires through the opening in the center of the door sensor wall plate.

CONNECTING MAGNET
Using a pocket-size straight blade screwdriver push down on the terminal button to open the socket, insert wire into the socket and release the terminal button. Insert one wire into each of the two (2) terminals. See image below for wire locations.

POWER CONNECTION
If using the wired powered option for the door sensor, using a pocket size straight blade screw driver, push down on the terminal button to open the socket. Insert wire into socket and release the terminal button. Insert one wire into each of the two (2) terminals. See following for wire locations. Connect the power wires from the door sensor to the PTAC

on terminals C & R. The wire harness kit PWHK01C is required for this connection.

Viewed from the back with the power block in the upper right corner.

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig6

Note : For battery connection, the jumper must be placed as shown above

Note : For a 24v powered connection, the jumper must be placed as shown above

Door Magnet Installation

NOTE : Magnet buckets are shipped from the factory with the magnets in position A. The position may change based on the door and door frame alignment.

Mount the door magnet holder on the front of the door where it will be as close as possible to the bottom of the motion sensor but no more than 1/8″ from the bottom center of the motion sensor (DD01E) when the door is closed.
Select the correct slot in the magnet holder (there are three slots) to obtain 15/16″ from the back of the sensor mounting plate to the center of the magnet. (If you can easily slide a business card between the magnet and the DD01E sensor, unit is properly placed vertically.) See the image below for magnet and sensor alignment.
Screw in place with the 2 screws provided. Open and close the door to make sure that the magnet holder and motion sensor will not interfere with the normal opening and closing of the door. See images on pages five and six.

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig8

Do NOT install batteries until you are ready to test the magnet location with DD01E.

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig9AMANA-DS01E-PTAC-Packaged-
Terminal-Air-Conditioner-fig9 AMANA-DS01E-
PTAC-Packaged-Terminal-Air-Conditioner-fig10

Select one of the three slots that place the magnet 15/16” from the sensor mounting plate on the door frame. See the following examples. The door frame and door usually will not align. Place the holder on the door and select the slot that places the magnet as close as possible to the 15/16” depth from the back of the DD01E mounting plate.

CONSTRUCTION STYLE

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig11

ABOVE SHOWS MAGNET 15/16” FROM THE SENSOR MOUNTING PLATE IN DIFFERENT SLOT POSITIONS

NOTE : Two (2) 1/4” spacers are provided in this kit for instances where the door is recessed behind the door trim. See Construction style 4 above. There is a line on the bottom of the DD01E to assist in aligning the magnet in the proper bucket location. Above graphics are for example only. Always measure and place the magnet in the proper slot to obtain the 15/16” needed between the magnet and the sensor mounting plate on the door frame.

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig12

IMPORTANT NOTE : When properly installed, the center line mark on the bottom of the DD01E will line up with the center of the line of the magnet holder containing the magnet. Choose magnet position A, B, or C to align the magnet 15/16” from the back of the DD01E.

Door Sensor Operation Verification

NOTE : Do NOT attempt to bind a DD01E unless proper operation has been validated.
To verify that the door sensor is installed properly:

  1. Install batteries into DD01E and snap the sensor onto the wall plate.
  2. Close the door. Green light in the lens should illuminate. Open the door and the green light will turn off. Repeat this step several times to ensure the door sensor is operating correctly.

The procedure must be accomplished within one minute. If not accomplished within one minute, remove batteries and repeat Steps 1 & 2.

Configuration Settings

The PTAC control will automatically self-configure to work with the wall thermostat (DS01E Kit) if installed and bound. The PTAC control will automatically self-configure to activate pre-configured energy management routine when the DD01E is installed and bound to the PTAC. Additionally, the setback times and setback temperatures can be changed using the configuration settings. If you are using DP01* Front Desk Platform, the PTAC control will need to be configured to identify its room number placement.

Standard and DS01E Configuration

To enter configuration feature mode:

Press and continue to hold the up and down arrow keys and quickly press the OFF key twice within a two (2) second time frame. You will see “ – – “ displayed. Once you are in the configuration program, you can use the HEAT button to move UP the various configuration settings or the COOL button to move DOWN the configuration settings. The + or – keys will move up or down the selectable codes that you can change for each configuration setting. Ensure that you are in the proper configuration setting before pressing the + or – key as you may accidentally change a setting that you did not intend to change.

The display will alternate between displaying the feature code C 1 and the option code 0 (factory default setting).

Press the HEAT button one time to get into C1 mode and then the display will alternate between C1 and 0 – the factory default. If an RF DS01* has been bound to the unit the display will alternate between C1 and rE. The lower right dot on the display will flash.

DP01A, DP01E or DL01E

*Entering Room Number (Skip if not using DP01 Front Desk Platform)**

  1. The PTAC control can be set for a 4-digit room number. To select the first two digits (floor), press the HEAT key until C4 appears, then press the up down arrows to select the first two digits.

  2. To select the last two digits of the room number, press the HEAT key until C5 appears, then press the up and down    arrows to select the last 2 digits of the room number.

    • For example for Room “201”, press the HEAT key until  C4 appears, then press the up  down arrows Next to select the last two digits of the room number, press the HEAT key until C5  appears, then press the up and down  arrows to select “01”: C5=01
  3. If a room contains more than one unit (a suite), a suffix must also be entered to identify which unit is in the main room and which unit(s) are in the bedroom(s). Master unit ALWAYS MUST have a 01 suffix and slaves a suffix or 02, 03, etc. To select the room # suffix, while still in configuration mode, press the HEAT key until r5 appears.
    Then press the up and down arrows to select the room # suffix. Example: For the unit serving the main living area in room 224, press the HEAT key until r5 appears, then press the up and down  arrow keys to it may not be necessary to configure the suffix for the main room.

    • For the bedroom unit closest to the main room in room 224, press the up and down  01 (r5 =01) appears in the display) Press the OFF key to exit configuration mode.
  4. If a property identifies rooms by an alpha character (such as WINGS), a prefix must also be entered to identify room numbers (example: A-115). To select the room # prefix, while still in configuration mode, press the HEAT key until r4 appears. Then press the up and down arrows to select the room # prefix. Contact the manufac-turer to have the prefix show as the correct letter on the platform.

Binding of RF Devices

  • CAUTION
    • DO NOT HAVE TWO GROUPS OF PEOPLE BINDING UNITS IN THE PROPERTY AT THE SAME TIME. RADIO FREQUENCY (RF) GOES THROUGH WALLS AND UP TO 400′.

IMPORTANT NOTE : If wireless platform DP01*, DP01E or DL01E are being utilized, then room numbers MUST BE CONFIGURED in the control board prior to binding wireless devices.

DO NOT ATTEMPT TO BIND MORE THAN ONE ROOM AT A TIME AT THE SAME PROPERTY!!!

RF TRANSMITS THROUGH WALLS.

The wireless devices (DS01E and or DD01E must be bound to the PTAC DT01E control for proper in-room communication. Ensure the unit is powered but in the OFF position.

NOTE : Both the DS01E and the DD01E must be bound to the PTAC unit during the same “learn” opera-tion. If you need to rebind one device – then you must rebind both devices during the same learn mode event. All must be bound at one time.

  1. Press and hold OFF button on the PTAC until appears.
  2. Press and then immediately release the white tactile button on the back of the DS01* thermostat. should now be displayed on the PTAC LED display. If  does not show on the display in 1-2 seconds, then press and release the white button a second time. Skip this steif there is no thermostat.
  3. Press and then immediately release the white tactile button on the back of the DD01* motion sensor. or should now be displayed on the PTAC LED display. If or    does not show on the display in 1-2 seconds,   then press and release the white button a second time.
    • NOTE : If both a DD01 and a DS01 are being bound, then the display will show .   
  4.  Press “OFF” on the PTAC touchpad to exit the binding sequence.
    • Skip if there is no motion sensor.
  5. Slide top of the thermostat down onto the wall plate and then snap into place.
  6. Provided optional security screws may be used in lower corners of the thermostat.AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-fig19
  7. Snap motion sensor onto motion sensor mounting plate.
  8. Provided optional security screws may be installed on right and left side of the sensor.
  9. If you wish to change from the factory default settings, configure the device or devices that were bound. See the next section for configuration choices.

NOTE : If a wireless device is replaced or added, all devices (including those previously bound) will need to be bound/re-bound to the unit. See directions above.

CONFIGURATION SETTINGS CHART

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig20

Setback Temps – DD01E

The DD01 and the DigiSmart™ control can be programmed for 3 different times to activate temperature setbacks. The current factory default temperature setbacks in v2.5 software release are: 2º from set point in 30 minutes, 3º in one (1) hour, and 6º in three (3) hours. For each time, you can select a setback temperature. The amount of setback is the number of degrees the control will operate from guest’s setting in degrees F. If a change to the factory default temperature settings is desired, use the following instructions.

NOTE : When first entering the configuration mode, if you see “ – – ” then you have version 2.5 or higher. You can verify the software version by starting with the unit in the OFF position, and while holding down the “+” and “-” buttons , double click the COOL button and then release and push the FAN button within one  second. The unit display will scroll through all of the thermister temperatures and the last item displayed will bs CS (current software) and you will see 25 for v2.5.

Other software versions may have different factory setback defaults. Contact your PTAC representative to determine factory default settings.

WARNING

USE OF SETBACK TEMPERATURES DO NOT USE MOTION SENSING SETBACK TEMPERATURES IN ROOMS WHERE INCAPACITATED PERSONS OR ANIMALS ARE UNABLE TO CHANGE THE CONTROL SETTING. AN UNATTENDED AIR CONDITIONER WITH EXTREME SETBACKS MAY RESULT IN UNDESIRABLE OR UNHEALTHY TEMPERATURES IN THE CONDITIONED SPACE, CAUSING UNDERHEATING, UNDER COOLING, OR DEATH OF PERSONS OR ANIMALS.

4. To select first unoccupied setback temperature, press the HEAT key until d7 feature code comes up. To scroll to a previously viewed feature codes, press the COOL key. Once you have scrolled to the d7feature, press either the up or down arrow to scroll to the desired first unoccupied setback temperature. Cooling example: 720 (guest set point) + 20 (Setback temperature) = 740 (operational set point).

5. Press HEAT key to scroll to d8 first unoccupied setback time. The first unoccupied setback time is the time between when the control determines that the room is not occupied and when the control sets the operatingset point temperature back. The increments are in hours (.1 = 6 mins., .5 = 30 mins., 1 = 1 hour, etc.). Press either
the up or down arrow to the desired first unoccupied setback time. c

6. To select second unoccupied setback temperature, press the HEAT key until d9 comes up. Press either the up or down arrow to the desired second unoccupied setback temperature. Cooling example: 720 (guest set point) + 40 (Setback temperature) = 760 (operational set point).

7. Press the HEAT key to scroll to dA second unoccupied setback time. Press either the up or down arrow to the desired second unoccupied setback time. Example: Operating set point would be 760 instead of 720, one hour (1.0 hour) after guest leaves room.

8. Press the HEAT key to scroll to d6 the third unoccupied setback temperature. Press either the up or down arrow to the desired third unoccupied setback temperature.

9. Press the HEAT key to scroll to dC the third unoccupied setback time. Press either the up or down arrow to the desired third unoccupied setback time.

10. To exit configuration mode: Press the OFF key.

NOTE : Configuration feature mode will also automatically exit if no keys repressed for a period of two (2) minutes.

The changes made in configuration mode are now in effect.
NOTE : Additional codes are present and may be accessed within this menu. Contact the manufacturer for additional information.

Suggested Wireless Thermostat Locations in Typical Room Layouts

Select a thermostat mounting location about five feet above the floor, on an inside wall, out of direct sunlight, away from sources of radiant heat (lamps, fireplaces, heating and air conditioning equipment, etc.), away from windows or door to  the outside, and avoid areas with poor air circulation. Ensure location is out of the path of foot traffic where a person accidentally bumps into the thermostats and damages the device.

NOTE : Due to the motion sensor inside the thermostat, do not point towards a window.

AMANA-DS01E-PTAC-Packaged-Terminal-Air-Conditioner-
fig21

CAUTION

This equipment is authorized for use under the United States Federal Communication Commission Rules and Regulations, Code of Federal Regulations part 15 and must be installed in accordance with the instructions provided in this document. Failure to install or operate this equipment as instructed in this document could void the user’s authority to operate the equipment. This equipment contains no user-serviceable parts. Any modification or repairs to the internal components or to the an- antenna configuration of the equipment without the express written consent of Everex Communications, Inc., could void the user’s authority to operate the equipment.

NOTE : To comply with FCC RF exposure requirements in section 1.1307, a minimum separation distance of 20cm (8 inches) is required between the equipment and all persons.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will occur in a particular  installation. If this equipment does cause harmful interference toradio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • * Reorient or relocate the receiving antenna.
    • Increase the separation between the equipment and the receiver.
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for help.

AMANA is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.

  • Goodman Company, L.P.
  • 5151 San Felipe, Suite 500 • Houston, TX 77056
  • www.amana-ptac.com

© 2009 – 2010 Goodman Company, L.P. 16

References

Read User Manual Online (PDF format)

Loading......