Security information

  1. To reduce the risk of an electrical blow, electricity on the protective switch or the safety box went out before starting.
  2. All wiring must correspond to the NASI/NFPA 70-1999 National Electric Code and local electrical regulations. The electrical installation must be carried out by a qualified and approved electrician.
  3. The connection box and support construction must be assembled safely and 35 pounds (15.9 kilos) must be able to transport reliably. Use only output boxes listed with the labeling “Accepted for fans with a weight of 35 (15.9 kilos) or less.”
  4. The fan must be installed with a minimum distance of 2.1 m (7 feet) from the posterior edge of the wings to the floor.
  5. Do not operate the reverse switch if the fan wings are moving. You have to turn off the fan and stop the wings before reversing the direction of the wing.
  6. Do not place objects on the road to the wings.
  7. To avoid lesions or damage to the fan and other objects, be careful if you work on the fan or clean it.
  8. Electrical diagrams only serve as a reference. The lighting rates that are not delivered with the fan must be listed and marked with the valve model that will be installed for use. The switches must be general-use switches UL. Take into account the instructions for the appropriate installation included in the lighting rates and the switches.
  9. After the electrical connections have been made, the size staircase must be turned up and carefully pushed to the plug box. The cables must be distributed in such a way that the ground connected driver and the device head are next to the socket. All fixing screws must be verified before installation and, if necessary, followed.

WARNING : To reduce the risk of injury, knife supports (also known as flanges) cannot be folded during installation or after installation. Do not put any object on the path of the wings.
WARNING : Remove rubber motor attacks at the bottom of the fan before mounting the wings or trying the engine.
WARNING : To avoid the risk of a fire or an electrical blow, this fan should not be used with a semiconductor speed controller.
WARNING : To avoid a possible electric shock, tum off the current in the main security box before wiring. If you feel that you do not have enough knowledge or experience in electrical wiring, communicate with a licensed electrician.
WARNING : Electrical diagrams only serve as a reference. The optional use of a lighting rate must be on the list and marked with this fan for use.
WARNING : To reduce the risk of fires, electrical discharges, or injuries, assemble the device in a socket with the inscription accepted for fans with a weight of 35) or less. It is marked and use the screws supplied with the plug

TECHNICAL INFORMATION

PARTS

Parrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG-
\(1\)

REMOTE CONTROLParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG-
\(2\)

Take the finished F4723-SMART out of the packing box

INSTALLING THE FAN:

Tools Required: Phillips screwdriver, pair of pliers, straight slot screwdriver, adjustable wrench, step ladder, and wire cutters.

INSTALLING THE MOUNTING BRACKET:

The ceiling fan must be installed in a location so that the blades are 12(300mm) spacing from the tip of the blade to the nearest objects or walls. When hanging the Fan REMEMBER to turn off the power. Follow the instructions below to hang your fan properly:

  1. For wood ceilings, Secure the mounting bracket to the ceiling is capable of carrying a load of at least 100lbs (45kgs) with two long mounting screws and washers provided. Be sure at least 0.12°(30mm) of the screw is threaded into the supportParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(4\)
    Note
    Check whether it is securely installed

  2. For installing to outlet box, secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the moving weight of the fan (at least 100 lbs). Use a UL-listed metal outlet box. Do not use a plastic outlet box. Figure 1 & 2 examples to mount the outlet box.Parrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(5\)

  3. Use a Phillips screwdriver to loosen the screw in the direction of the arrow shown in the figure, and place the screw for subsequent installationParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(6\).

  4. Install the suspension system components of the product as shown in the diagramParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(7\).

  5. To prevent loose, the drop ball groove must be engaged with the hanger lugParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(8\)

  6. Safety rope installation procedureParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(9\).

  7. Remote control wiringParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(11\)

  8. Wiring and installation of lighting fixturesParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(12\).

  9. Lampshade installation

  10. Installing E26 bulb

  11. The product installation is completeParrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG- \(15\)

Remote controller

INSTRUCTION OF INSTALLATION AND OPERATIONParrot-Uncle-F4723-SMART-52
-Broxburne-Smart-Fan-Light-FIG- \(16\)

INSTALLING RECEIVER IN CEILING FAN

Safety precautions:
WARNING : HIGH VOLTAGE! Disconnect power by removing a fuse or switching off the circuit breaker. Do not use with solid-state fans. Electrical wire must meet all local and national electrical code requirements. Supply for fan must be 110/120 volt, 60Hz. Maximum fan motor amps: 1.0, Maximum light watts: 180 incandescent or ballast and LED. Otherwise, power can cause serious injury or death.

Installing receiver in fan:

  • Remove power from the circuit.
    Remove the ceiling fan canopy from the mounting bracket.

  • Disconnect existing wiring between the ceiling fan and Supply in the electrical junction box.

  • Make connections as follows, using the wire nuts supplied:

CAUTION:
Ceiling Angle Shall Not Exceed 30 Degrees,For the Mounting Controller, Model: RE-028W

CONNECT TO

  • Green fan wire ….Bare supply wire
  • Red or Black receiver wire(AC IN L) ….Red or Black supply wire
  • White receiver wire(AC IN N) ….White supply wire
  • White receiver wire(TO MOTOR N) ….White fan wire
  • Black receiver wire(TO MOTOR L) ….Black fan wire
  • Blue receiver wire(FOR LIGHT) …. Blue light wire
  • Purple receiver wire (FOR REV) ….Purple rev wire

Parrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG-
\(17\)

If other fans or supply wires are different colors, have this unit installed by a qualified licensed electrician

  • Push all connected wires up into the junction box.
  • Lay the brown antenna wire on top of the receiver, and put the receiver into the mounting bracket.
  • Reinstall the canopy on the mounting bracket.
  • Restore power.
  • Install 3-volt battery. (To prevent damage to the transmitter, remove the battery if not used for a long time).
  • Store the transmitter away from excessive heat or humidity.
  • This remote control unit is equipped with roll code combinations. To prevent possible interference from or to other remote units such as garage door openers, car alarms or security systems.

If you find that your fan and light kit go on and off without using your remote control, simply change the code combination in your transmitter and receiver

OPERATING TRANSMITTER:
Operating the buttons on the panel of the transmitter.

  • 3 key -for fan high speed.
  • 2 key-for fan medium speed.
  • 1 key-for fan low speed.
  • OFF key-for fan off.
  • REV key-for fan rev.
  • LIGHT key for light on and off.
  • LIGHT+ key-for light dimmer +.
  • LIGHT- key-for light dimmer —

YOUR REMOTE NOW HAS FULL CONTROL OF THE FAN AND LIGHT

TROUBLESHOOTING GUIDE

  • Receiver power?
  • Receiver wired correctly?
  • Fan manual speed control in the highest position?
  • The light kit switch turned on?
  • The good battery in the transmitter ?

If there are two or more ceiling fans installed in the same house, to prevent your ceiling fans from being affected by the remote control of the adjacent ceiling fans, first turn the switch in each remote control transmitter to the CODE(locked) position (see the schematic diagram FIG1) Remarks: The standard state of the transmitter is in the common code COM. (Power-off means you need to use a wall switch to shut down the power of the ceiling fan, if you do not have a wall switch, please power off the whole room from the air circuit breaker for each room)

After installing the remote control receiver on the ceiling fan

  1. Turn on the power of the 1# ceiling fan receiver (the power of the 2# receiver is kept in a power-off state), within 30 seconds after the fan power is turned on, press the LEARN button corresponding to the 1# transmitter, then The receiver will learn the transmitter code. When the transmitter code is learned successfully, the light of the ceiling fans will flash twice, and then it can be used normally.
  2. Turn on the power of the 2# ceiling fan receiver (the power of the 1# receiver is kept in the power-off state), within 30 seconds after the fan power is turned on, press the LEARN button corresponding to the 2# transmitter, then The receiver will learn the transmitter code.
    When the transmitter code is learned successfully, the light of the ceiling fans will flash twice, and then it can be used normally. And so on, only one ceiling fan is powered on each time the corresponding transmitter learns.

FCC Statement

  1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital, under Part 15 or the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna.

  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.

WARNING
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH A WALL CONTROL/SWITCH.

Size of product

Parrot-Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-
FIG- \(20\)Parrot-
Uncle-F4723-SMART-52-Broxburne-Smart-Fan-Light-FIG-
\(21\)

AFTER INSTALLATION

WOBBLE”
The fan blades have been adjusted in the factory to minimize any wobble
NOTE : CEILING FANS TEND TO MOVE DURING OPERATION BECAUSE THEY ARE MOUNTED ON A RUBBER CROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE CEILING, IT WOULD CAUSE EXCESS VIBRATION. MOVEMENT OF A FEW CENTIMENTERS IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE MOUNTING BRACKET AND DOWNROD ARE SECURE.

BALANCING A WOBBLING CEILING FAN:

  1. Check that all blade and blade arm screws are secure.
  2. Most fan wobbling problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure this distance. Rotate the fan until the next blade is positioned for measurement. Repeat for each blade. The distance deviation should be equal to 1/8″(0.32cm).
  3. If the blade wobble is still noticeable, interchanging two adjacent (side-by-side) blades can redistribute the weight and possibly result in smoother operation.

WARNING :
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE ARM WHILE INSTALLING, BALANCING THE BLADES, OR CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.

NOISE
When it is quiet(especially at night) you may hear occasional small noises. This is normal. Please allow a 24- hour “breaking-in” period, most noises associated with a new fan disappear during that time.

CARE AND CLEANING

  1. Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to avoid scratching the paint finish. Please make sure to turn o X electricity power before you clean your fan
  2. Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
  3. Motor has permanently lubricated ball bearing. No need to oil
    NOTE : MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT ANY CLEANING OR REPAIRS.