biamp Apprimo Touch 8i Control Panels User Guide
- June 17, 2024
- biamp
Table of Contents
Apprimo
Touch 8i Control Panel
Installation and Operation Guide shown on the attached Table Mount
PRODUCT DESCRIPTION
The Apprimo Touch 8i is an 8″ control panel for any room that requires a more complex level of control, while still being a stylish and discreet interface that fits in any type of interior design.
FEATURES
- 8″ capacitive touch LCD interface
- Scratch-resistant glass
- Display brightness can adjust automatically to the ambient light level
- Customizable user interface to fit customers’ control requirements and corporate identity
- PoE powered (IEEE 802.3at Class 3, 15W) for simple, single CAT5e/CAT6 cable installation
CONTENTS
Apprimo Touch 8i
(with table mount attached)
Reset Pin
3 m (10 ft) Cat5 cable
PRODUCT INSTALLATION
Table Installation
- Remove cover from the bottom of the table mount.
- Insert network cable into port on the back of the control panel.
- Reattach the cover routing the cable through the notch in the latch and stand.
- Follow on-screen prompts to complete the installation.
OPERATION
A simple touch will wake up the control panel. It provides a method of
interacting with or controlling the room system. The initial interface and on-
screen prompts make use of the control panel default setup.
Note: More options can be enabled upon setup, including user proximity to
“wake up” the panel.
INFORMATION and SOFTWARE LINKS
Information regarding setup and configuration:
- Biamp Control on Cornerstone – search for articles about the Apprimo 8i
- Project Designer: Option to configure the user interface on the Apprimo 8i Available by request here.
MAINTENANCE
Cleaning: Use a soft cloth (microfiber recommended) to clean the glass
and cabinet. Do not use abrasives or solvent-based cleaning products. If
necessary, use a specially formulated screen cleaner on a soft cloth to wipe
any smears off the control panel. Wipe with a dry cloth to remove any residual
moisture.
Settings: Insert reset pin into the designated hole in the top of the
control panel rear. A simple press will bring up the device settings screen.
Note: Inserting the pin in the other hole will initiate a device reboot.
ACCESSORIES (OPTIONAL)
It is necessary to remove the Table Mount from the control panel in order to mount the panel to any of the accessory wall mounting options. The instructions to remove the table mount are on the next page. Do this before proceeding with the accessory mount instructions. Clicking the links in the table below will take you to the chosen instructions.
Model Name | Description | Mounting Type** |
---|---|---|
Apprimo 8-WMA | Angled wall mount bracket | To drywall or gang box |
Apprimo 8-WMF | Flat wall mount bracket | To drywall or gang box |
Apprimo 8-WMC | Concrete (surface) wall mount | To a solid surface wall |
Apprimo 8-WML | Low profile wall mount bracket | For drywall / sheet rock |
Apprimo 8-WMA/WMF: Any existing gang box must be flush with the mounting
surface. This may require recessing or removing the gang box prior to
installing the mounting plate on the wall.
Failure to follow this instruction will result in the control panel not siting
firmly and flush against the wall.
- Shown connected to a single gang box (US). Mounting base plate will accept most gang box types.
** Anchoring / mounting hardware and gang boxes are not included and must be appropriate for the surface and conform to local building codes
Determine placement on the wall
-
The center of the control panel would typically be located between 102 – 165 cm (40″ – 65″) above the finished floor. Route Cat 5e/6 cable to the location. There are channels and/or knockouts on the base plates for cable routing if installing on a solid wall. The Low Profile mounting option is designed work with network cabling inside the wall space.
Note: Follow local guidelines for accessible wall controls. Installations complying with US ADA guidelines the top of the panel should not exceed 122 cm (48″) from the floor.
Remove table mount from the control panel -
Remove cover from the rear of the table mount.
-
Remove screw holding table mount to control panel.
-
Remove mount by sliding it down and then lifting up.
Install Flat or Angled Wall Mount (Apprimo 8-WMF, Apprimo 8-WMA)
The control panel can be mounted to a wall with or without a gang box. Most
gang box styles are supported.
NOTE: The wall plate may be shipped attached to the flat or angled base.
Use a small flat screwdriver to release the latched tab and lift the wall
plate away from the base.
-
Attach wall plate directly to the wall with screw anchors or screw it to a gang box (most gang box styles are supported). Orient the plate with the arrows pointing up.
IMPORTANT: Any existing gang box must be flush with the mounting surface. This may require recessing or removing the gang box prior to installing the mounting plate on the wall. Failure to follow this instruction will result in the control panel not siting firmly and flush against the wall. Both Flat and Angle wall mounting options are shown below. The Angle Mount has a notch to route the cable through if mounted on a solid wall. -
Attach wall mount base to control panel – fit clips in control panel back (a), and slide up (b).
-
Secure base with a screw.
-
Insert network cable into port on the back of the control panel.
-
Mount the panel on the wall plate by hanging it on the top tabs then rotating in and clipping into the bottom tab. Ensure the tab is fully engaged (see circled views).
Install Concrete Wall Mount (Apprimo 8-WMC)
NOTE: The wall plate may be shipped attached to the concrete mount base.
Use a small flat screwdriver to release the latched tab and lift the wall
plate away from the base.
- Securely attach wall plate directly to the wall with concrete anchors (or construction adhesive). Orient the plate with the arrows pointing up.
- Attach wall mount base to control panel – fit clips in control panel back (a), and slide up (b).
- Secure base with a screw.
- Insert cable plug in the jack and route cable down or up. An opening is available if the cable is routed down (a). There is a small knockout at the top of the mount that should be removed (b) to route the cable up.
- Mount the panel on the wall plate by hanging it on the top tabs then rotating in and clipping into the bottom tab. Ensure the tab is fully engaged in the base’s slot.
Install Low Profile Mount Bracket (Apprimo 8-WML)
Network cabling must be routed to the desired panel location.
-
Cut a rectangular hole in the wall (drywall or sheet rock).
Dimensions H x W: 90 x 122 mm (3.5 x 4.8″)
Note:The hole must have clearance of 25mm (1″) on either side of the hole to accommodate the full clamp rotation. -
Insert the bracket into the hole.
-
Screw the clamps down to secure the plate in the wall.
-
Attach baseplate to control panel – fit clips in control panel back (a), slide up (b), and secure with screw (c).
-
Plug network cable in the back of the control panel and feed excess wire into the wall.
-
Position the panel’s backplate aligned with, and against all four magnets in the low profile bracket. The panel will be held securely on the wall.
CONTACT US
Email:support@biamp.com
Web:support.biamp.com
Warranty:biamp.com/legal/warranty-information
Safety & Compliance: biamp.com/compliance
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA
W:www.biamp.com
17AUG2023
Documents / Resources
|
biamp Apprimo Touch 8i Control
Panels
[pdf] User Guide
Apprimo Touch 8i Control Panels, Apprimo Touch 8i, Control Panels, Panels
---|---
References
- Home - Biamp Cornerstone
- Biamp-Downloads
- Biamp Control - Biamp Cornerstone
- Biamp Project Designer
- Warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>