CHOICEMMED AMERICA BP201 Wrist Blood Pressure Monitor Instruction Manual

June 17, 2024
CHOICEMMED AMERICA

CHOICEMMED AMERICA BP201 Wrist Blood Pressure Monitor

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-
product

Product Information

Specifications:

  • Model: BP201
  • Language: English
  • Instruction Guide Version: 1.0
  • Manufacturer: Manual Hub
  • Website: https://manual-hub.com/

IMPORTANT INFORMATION:

  • Please read this instruction manual thoroughly so that you completely understand the operations, cautions, performance, and limitations of this monitor. After reading this manual, please keep it for future reference.
  • You should not use this blood pressure monitor for self-diagnosis, self-treatment, or to change medication without consulting your physician or other health care professional. Should you have any doubt or question about your blood pressure measurements, you should consult your physician or other health care professional.
  • This device contains high-precision parts; therefore, avoid exposing it to extreme temperature or humidity, direct sunlight, shock, and dust.
  • Do not attempt to calibrate or repair this monitor. If you have any questions regarding the function or operation of this monitor, please contact our service agent so we can provide you with accurate information.
  • Should the monitor or cuff need cleaning, use a dry, soft cloth or a cloth dampened with water and a mild detergent. Never use alcohol, benzene, thinner, or other harsh chemicals to clean the monitor or cuff.
  • Remove and replace the batteries if the monitor is not used for more than 6 months. Alkaline batteries are recommended.

PRECAUTION FOR USE:
The BP201 Wrist Automatic Blood Pressure Monitor is designed to be operated by anyone who is eighteen years and older or by medical professionals to monitor blood pressure (systolic and diastolic) and pulse rate.

BEFORE YOU START:
Please make sure you have installed 2 AAA (3 volt) batteries (alkaline batteries recommended). To install batteries or replace them if the Low Battery symbol appears on the display, proceed as follows:

Battery Loading:

  1. Remove the battery compartment cover by gently pushing down on the arrow and sliding the cover forward.
  2. Place batteries with positive (+) and negative (-) terminals into the compartment and make sure they match the indicated terminals in the compartment.
  3. Close the battery cover by gently sliding it into the compartment and pressing it into place.

Note: When the LCD display shows a Low Battery signal, the batteries must be replaced for accurate readings. Do not use rechargeable batteries with a voltage of 1.2V each because they are not suitable for this product and will cause inaccurate readings. Remove the batteries if the monitor will not be used for six months or longer to avoid damage from the possibility of leaking batteries. All the measurements will remain in the memory should the batteries become drained, removed, or replaced.

MONITOR COMPONENTS:

  • MEMORY Button / Clock Setting
  • ON/OFF Button / Clock Adjusting
  • LCD Display
  • Systolic Indicator
  • Diastolic Indicator
  • Pulse Indicator

DISPLAY OF LCD:

Mode for LCD display:

  1. Date: Month – Day
  2. Time: Hour – Minute
  3. Systolic Blood Pressure (unit: mmHg)
  4. Diastolic Blood Pressure (unit: mmHg)
  5. Pulse (unit: beat/minute)
  6. WHO BP Classification Indicator
  7. Inflation / Deflation Indicator
  8. Blood Pressure Measurement Unit
  9. Low Battery Indicator
  10. Irregular heartbeat Indicator
  11. Memory Record Number

IMPORTANT INFORMATION

  • Please read this instruction manual thoroughly so that you completely understand the operations, cautions, performance, and limitations of this monitor. After reading this manual, please keep it for future reference.
  • You should not use this blood pressure monitor for self-diagnosis, self-treatment or to change medication without consulting your physician or other health care professional. Should you have any doubts or questions about your blood pressure measurements, you should consult your physician or other health care professional.
  • This device contains high-precision parts; therefore, avoid exposing it to extreme temperature or humidity or to direct sunlight, shock, and dust.
  • Do not attempt to calibrate or repair this monitor. If you have any questions regarding the function or operation of this monitor, please contact our service agent so we can provide you with accurate information.
  • Should the monitor or cuff need cleaning, use a dry, soft cloth or a cloth dampened with water and a mild detergent. Never use alcohol, benzene, thinner, or other harsh chemicals to clean the monitor or cuff.
  • Remove and replace the batteries if the monitor is not used for more than 6 months. Alkaline batteries are recommended.

PRECAUTION FOR USE
The BP201 Wrist Automatic Blood Pressure Monitor is designed to be operated by anyone who is eighteen years and older or by medical professionals to monitor blood pressure (systolic and diastolic) and pulse rate.

BEFORE YOU START
Please make sure you have installed 2 AAA (3 volt) batteries (alkaline batteries recommended), to install batteries or replace them if the “Low Battery” symbol appears on display), proceed as follows:

Battery Loading

  • Remove the battery compartment cover by gently pushing down on the arrow and sliding cover forward.
  • Place batteries with positive “+” and negative “-“ terminals into the compartment and make sure they match the indicated terminals in the compartment.
  • Close the battery cover by gently sliding it into the compartment and pressing it into place.

Note:

  • When the LCD display shows a “Low Battery” signal, the batteries must be replaced for accurate readings.
  • Do not use rechargeable batteries with a voltage of 1.2Veach because they are not suitable for this product and will cause inaccurate readings.
  • Remove the batteries if the monitor will not be used for six months or longer to avoid damage from the possibility of leaking batteries.
  • All the measurements will remain in the memory should the batteries become drained, removed, or replaced.

MONITOR COMPONENTS

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig-
\(4\)

  • “MEMORY” Button /Clock Setting
  • “ON/OFF” Button / Clock Adjusting
  • LCD Display
  • Systolic Indicator
  • Diastolic Indicator
  • Pulse Indicator

DISPLAY OF LCD

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig-
\(5\)

Mode for LCD display:

  1. Date: Month – Day
  2. Time: Hour – Minute
  3. Systolic Blood Pressure (unit: mmHg)
  4. Diastolic Blood Pressure (unit: mmHg)
  5. Pulse (unit: beat/minute)
  6. WHO BP Classification Indicator
  7. Inflation / Deflation Indicator
  8. Blood Pressure Measurement Unit
  9. Low Battery Indicator
  10. Irregular heartbeat Indicator
  11. Memory Record Number

TIPS FOR BLOOD PRESSURE MONITORING

  • Relax for about 5 minutes before measurement.
  • Do not smoke or ingest caffeine at least 30 minutes prior to measurement.
  • Remove any constricting clothing or watch and place the cuff on a bare wrist.
  • Keep still and do not talk until the measurement is complete.
  • The cuff must be neither too tight nor too loose. Using a little force, you should be able to place two fingers between the cuff and your wrist.CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig- \(6\)

TAKING A MEASUREMENT

POSTURE FOR TAKING BLOOD PRESSURE MONITOR

  • Make yourself comfortable and sit-up straight
  • Place the wrist with cuff in front of you on the table with the palm up. Do not bend your wrist or curl your fingers.
  • Cuff should be at the same height as your heart.

HOW TO WRAP THE CUFF

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig-
\(7\)

  • Place the cuff around a bare wrist ½ or ¾ of an inch above the wrist joint on the opened-hand side of the wrist.
  • Keep the cuff at the same level as your heart.
  • Unless your physician recommends otherwise, use the left wrist to measure pressure.
  • The cuff should be snug but not too tight. You should be able to insert two fingers between the cuff and your wrist.

LCD DISPLAY FOR TAKING BLOOD PRESSURE
After you are in a comfortable position, press the “ON/OFF” button. The device will verify itself showing all “8s”, then LCD will show “00”.

CLOCK AND DATE ADJUSTMENT

  • When the monitor is turned off, press ON/OFF and the ‘MEMORY’ buttons for 3 seconds at the same time. The number of the year will blink on the LCD display. When the MEMORY button is again pressed and released, the month will blink. Repeat the process and the day of the month, the hour and minute will blink.

  • When the number that you wish to set is blinking, each time you press and release the ‘MEMORY’ button, the number will increase by one for the year, month, day, hour or minute.
    Note : The hours are displayed as 1 through 24 Rather than 12 AM hours and 12 PM hours

  • When batteries are replaced, the time and date must be reset.

IRREGULAR HEARTBEAT INDICATOR
If an irregular heartbeat is detected, the Irregular Heartbeat symbol will appear and blink in the display window.

DELETING MEASUREMENT FROM THE MEMORY
Press and hold the ‘MEMORY’ BUTTON until all numbers change to ‘ZERO’.

EVALUATING BLOOD PRESSURE FOR ADULTS
The following standards for assessing high blood pressure (without regard to age or gender) have been established as a guide according to WHO (World Health Organization). Please note that other risk factors (e.g. diabetes, obesity, smoking, etc.) need to be taken into consideration and may affect these figures. Always consult with your physician or other health care professional for accurate assessment.

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig-
\(12\)

WHO CLASSIFICATION OF BLOOD PRESSURE

Blood

Pressure Classification

| SBP

(mmHg)

| DBP

(mmHg)

| COLOR INDICATOR
---|---|---|---
Optimal| <120| <80|

GREEN

Normal| 120-129| 80-84
High-Normal| 130-139| 85-89
Stage 1 Hypertension| 140-159| 90-99| YELLOW
Stage 2 Hypertension| 160-179| 100-109| ORANGE
Stage 3 Hypertension| ≥180| ≥110| RED

SPECIFICATION

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig-
\(13\)

TROUBLESHOOTING

Abnormality Probable Reason Corrective action
LCD shows Low Batter symbol Batteries are low. Install new batteries.
The unit does not measure. Readings are too high or too low. The pneumatic
system blocked or cuff is too tightly wrapped. Make certain the cuff is

wrapped around your arm correctly and re-measure.
Pressure system was unstable before measurement.| Measure again. Stay calm. Do not move or speak during measurement.
The cuff position is not correct.| Sit comfortably and still. Make sure the cuff is at the same level at your heart.
An irregular heartbeat symbol occurs.| Irregular heartbeat| Relax for about 5 minutes and measure again. If the symbol appears again, consult your physician or other health care professional.
Incorrect operation| Some interference in inflation or wrong operation during measuring| Refer to the inflation step in “Taking blood pressure” and process again.

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig-
\(12\)

Box Contents

  • 1 Wrist Blood Pressure Monitor
  • 1 Plastic Carrying Box
  • 1 Product Instructions
  • 2 AAA Alkaline Batteries

Symbols

CHOICEMMED-AMERICA-BP201-Wrist-Blood-Pressure-Monitor-fig-
\(13\)

LIMITED ONE-YEAR WARRANTY

ChoiceMMed America Co. warrants to the original purchaser that this equipment will be free from defects in materials and workmanship for a period of one year from the date of purchase. To obtain full warranty coverage, please be sure to complete your product registration within 30 days from date of purchase.

REGISTER ONLINE:
Visit www.choicemmedamerica.com/register

Fill out required information If you are unhappy with this product, we’ll replace it or give you your money back. For questions or comments, or to report any problems, please email support@choicemmedamerica.com.

Distributed by: ChoiceMMed America Co. 2558 Pearl Buck Road, Suite 8A Bristol, PA 19007
© 2014 ALL RIGHTS RESERVED Revised Date: July 23, 2014 Ver1.0

Frequently Asked Questions

Can I use this blood pressure monitor for self-diagnosis?

No, it is not recommended to use this blood pressure monitor for self- diagnosis. Please consult your physician or other health care professional for accurate medical advice.

How should I clean the monitor and cuff?

Use a dry, soft cloth or a cloth dampened with water and a mild detergent to clean the monitor and cuff. Never use alcohol, benzene, thinner, or other harsh chemicals.

What type of batteries should I use?

We recommend using 2 AAA (3 volt) alkaline batteries for optimal performance.

How often should I replace the batteries?

If the monitor is not used for more than 6 months, it is recommended to remove and replace the batteries to ensure accurate readings.

Can I use rechargeable batteries?

No, do not use rechargeable batteries with a voltage of 1.2V each as they are not suitable for this product and may cause inaccurate readings.

Will the measurements be saved if the batteries are replaced?

Yes, all the measurements will remain in the memory even if the batteries are drained, removed, or replaced.