BURCO 444448536 Electric Urn Instruction Manual

June 4, 2024
BURCO

BURCO - LOGO

These instructions cover the Burco C2T and C8T electric
444448536 Electric Urn
Instruction Manual

444448536 Electric Urn

****Please read and keep these instructionsBURCO 444448536 Electric
Urn

C2T C8T
444448536 444448535

Glen Dimplex UK Ltd., trading as, Glen Dimplex Heating & Ventilation Millbrook House, Grange Drive, Hedge
End, Southampton, SO30 2DF. Web: www.gdhv.com| Glen Dimplex Europe Ltd. Airport Road, Cloghran,
Co. Dublin, K67 VE08, Ireland Web: www.glendimplex.com|
---|---|---
Customer Service Tel: +44 [0]344 879 3588
Email: customer.services@glendimplex.com| Customer Service Tel: +353(0)1 842 833 Email:serviceireland@glendimplex.com
www.burco.co.uk

© Glen Dimplex. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex

INTRODUCTION

To ensure you obtain full benefits from your new urn:

  • Please read this instruction booklet carefully and follow all instructions.
  • If you are unsure of any aspect of the installation, use or performance of your appliance, please contact the after-sales number shown on the back page.

Specifications & Technical Data

Model| C2T| C8T
SKU Number| 444448536| 444448535
Height| 315mm| 530mm
Diameter| 210mm| 210mm
Water volume| 2.5 liter| 7.5 liter
Maximum draw off| 2.2 liter| 7.2 liter
Weight| 2kg| 3kg
Voltage| 220-240V ~50Hz
Power rating| 1840-2200W
Ambient Temperature| 5°C – 40°C

INSTALLATION

2.1 Installation Requirements
It is essential that this appliance is installed correctly. Installation should comply with all local electrical, and health and safety requirements.
2.2 Before Connection to Power Supply
Remove all packaging.
Check the appliance for damage. Report any damage immediately to the carrier or supplier.
Remove any protective plastic coating.
Any water in the urn is due to testing and is normal.
Check the available power supply corresponds to that shown on the appliance rating label.
2.3 Location

  • This electric urn is for indoor use only. The location must be frost free.
  • Allow at least 100mm clearance from any wall.
  • Only use on a flat level surface, that is adequate to support the weight when full of water. Do not lift or move the urn when it contains hot water or when the main lead is plugged in. The appliance is only to be installed in locations where its use and maintenance is restricted to trained personnel.
  • The mains lead should reach from the mains socket without straining the connections. Do not let the mains lead hang over the edge of the table or counter and keep it way from any hot surfaces.
  • Do not let the mains lead run across an open space.
  • Do not place the appliance where the main lead could fall into a sink. Do not place the appliance near a hot gas or electric burner

ELECTRICAL CONNECTION

3.1 Fitting a plug:

  • The mains lead of this appliance will already be fitted with a BS1363 13A plug.
  • If the fuse must be replaced, use a 13-amp fuse complying with BS 1362.
  • If the plug is not suitable for your socket, then the plug must be cut off and disposed of safely. An appropriate plug should be fitted as follows:

An appropriate plug must be fitted as follows:
The wires in the mains lead are colored in accordance with the following code:

Wire Colour Wire Name Wire Code
Green & Yellow Wires Earth E
Blue Wire Neutral N
Brown Wire Live L

The wire which is colored green and yellow must be connected to the terminal in the plug which is marked with the letter E or the earth symbol or colored green or green and yellow. The wire which is colored blue must be connected to the terminal which is marked with the letter N or colored black or blue.
The wire which is colored brown must be connected to the terminal which is marked with the letter  L or colored red or brown.
Make sure that the connections are tight and that there are no loose strands of wire and no insulation trapped under the terminals. Tighten the clamp in the plug making sure that it grips the outer covering of the cord. If fitting a BS 1363 13A fused plug, then fit a 13A fuse. Tighten the plug cover securely. If you are in any doubt, consult a qualified electrician.
IMPORTANT:
replace the supply cord if damaged. The supply cord may become warm when the appliance is in use.
WARNING – THIS APPLIANCE MUST BE EARTHED
Electrical connection: 220-240V ~50Hz, 8.4-9.2A, 1840-2200W
IMPORTANT:
This appliance can be used by children aged 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understanding the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
WEEE directive registration no. WEE/598W At end of unit life, dispose of the appliance and any replacement parts in a safe manner, via a licensed waste handler. Units are designed to be dismantled easily and recycling of all materials is encouraged whenever practicable.

USER GUIDE

4.1 Before Use
Fill to the ‘MAX’ line, boil and discard the water twice before general use.
TO AVOID BEING SCALDED, KEEP HANDS AWAY FROM ANY STEAM FROM THE LID WHEN THE URN IS OPERATING OR HAS JUST BEEN SWITCHED OFF.
TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG WHEN NOT IN USE, BEFORE CLEANING, AND BEFORE REPLACING ANY PARTS.
4.2 Filling
IMPORTANT: always put water in the urn before switching it on. Remove the lid by turning it anti-clockwise and filling the urn with the desired amount of water. Do not fill above the ‘MAX’ capacity mark.
WARNING: if the urn is overfilled there is a risk that boiling water will be ejected from around the lid. Underfilling may cause the thermal cut-out to operating (and may shorten the element life). Replace the lid by turning it clockwise to lock. The urn is not suitable for heating liquids other than water, or for heating water containing solids. If the water is being heated for tea making, make the tea in another container.
4.3 Controls
The green power indicator will be illuminated whenever power is connected to the urn. Turn the thermostat to the desired setting, the amber heating indicator will be illuminated whenever the element is on. This will go on and off as the thermostat maintains the selected temperature:

Knob Setting 1 2 3 4 5
Approximate Water Temp (°C) 30 43 56 69 82

THIS URN IS NOT INTENDED TO CONTINUOUSLY BOIL WATER, DUE TO THE HAZARDS OF STEAM AND WATER ESCAPING FROM UNDER THE LID.
If it is necessary to keep the water at an exact temperature, use a thermometer to check. Stir the water before taking the temperature and when the desired temperature has been reached, turn the control knob slowly to the left until a click from the thermostat is heard. The thermostat will then cycle on and off to maintain the temperature.
4.4 Operating the Tap
The tap has two open positions, one self-holding so that the tap remains open, and the other self-closing so that the tap closes as soon as the lever is released. Lift the lever up for the self-holding position, and press the lever down for the self-closing position. Return the lever to the horizontal position to close the tap.
4.5 After use
Turn the control knob to 0 and disconnect from the mains supply.
Water may be left in the urn when not in use for short periods, but to maintain a supply of fresh water, it should be emptied periodically and cleaned out.
WARNING: Only move the urn when it is disconnected and cool.
4.6 Protective cut-out
The heating element is fitted with a thermal cut-out which protects the urn from damage if allowed to boil dry or switched on without water. It is essential to keep the heating element free from scale to ensure the correct operation of this cut-out. Scale can cause the cut-out to operating when water is heating up normally. If the cut-out operates, allow the urn to cool down, drain out any water then press the red reset button situated under the base.

Cleaning

WARNING

  • ALWAYS TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG BEFORE CLEANING, ALLOW THE URN TO COOL
  • THIS URN IS NOT WATERPROOF
  • DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THE APPLIANCE, OR USE A WATER JET IN THE VICINITY OF THE APPLIANCE

5.1 Exterior
Clean with water and detergent. Do not use harsh abrasive cleaners as this could damage the surface finish.
5.2 Interior
Brush any scale or sediment from the element and rinse thoroughly with clean water.
5.3 Descaling
In hard water areas scale will form on the element and interior. This will adversely affect the operation of the urn if allowed to accumulate. Descale on a regular basis, using a proprietary descaler recommended for stainless steel kettles. Follow the instructions provided with the descaling product. Scale build-up can also cause the tap to drip. If this should occur, turn off the power supply and remove he plug. Empty the urn and allow it to cool. Unscrew the top of the tap from the body. Wipe, scrape and break the scale away from the rubber flexible seal and from the sealing surfaces inside the plastic body of the tap. Reassemble in reverse order.
5.4 Troubleshooting:

Fault Possible Cause Remedy
➢ The appliance does not operate ➢ No power to the appliance ➢ Check the

supply socket is switched on.
| ➢ Thermostat or element fault| ➢ Check green power indicator is illuminated
| | ➢ Replace thermostat (the element is not intended to be replaced)

WIRING DIAGRAM ELECTRIC CATERING URN

BURCO 444448536 Electric Urn - fig

SPARES LIST

ALWAYS TURN OFF THE POWER SUPPLY AND REMOVE THE PLUG BEFORE REPLACING ANY PARTS

Part Number Description Qty
82620789 Tap assembly 1
62462 Tap O ring 1
59215 Neon green 1
59214 Neon amber 1
62346 Thermostat 1
62254 Thermostat control knob 1
62657 Reset rod tube 1
62784 Conical spring 1
82610785 Reset rod 1
59108 Cut-out thermostat 1
62801 Limit thermostat 1
62658 Spiderfixes push-on 2
83335504 Handbook 1

GUARANTEE

This electric urn is guaranteed against defective materials or faulty workmanship, for a period of 12 months on labor and 36 months on parts.
This guarantee is given subject to the appliance being used in accordance with the instructions supplied, and on the supply, voltage marked on the rating label. The guarantee is subject to fair wear and tear conditions.
The guarantee does not cover consequential damage arising out of any failure acceptable under the guarantee, nor does it cover damage resulting from misuse, accident or unauthorized alterations to the appliance.
Proof of purchase will be required.
In any communication with the supplier or manufacturer, quote the model and serial number marked on the appliance rating label.
This guarantee does not affect your statutory rights.
The products are intended for commercial use as detailed in these instructions.
The Company has a policy of continuous improvement in product quality and design. The Company, therefore, reserves the right to change the specification at any time.
IMPORTANT: any service call resulting from a lack of regular descaling is not covered by this guarantee and will be chargeable.
PAGE INTENTIONALLY LEFT BLANK
Disregarding the instructions given in this manual in its entirety and any relevant regulations, standards, and code of practice will void the guarantee of this product. Glen Dimplex reserve the right to revise products, literature, and guarantee terms without prior notice due to a policy of continuous improvement
To speak to customer services please contact (UK & ROI):

Glen Dimplex UK LTD.
Millbrook House Grange Drive, Hedge End,
Southampton, SO30 2DF
Telephone: +44 [0]344 879 3588
Fax: 0844 879 3583
Email: customer.services@glendimplex.com
Or
Glen Dimplex Europe Limited
Airport Road, Cloghran,
Co. Dublin, K67 VE08, Ireland
Telephone: +353(0)1 842 833
Email: serviceireland@glendimplex.com
083335504 © ISS 4BURCO 444448536 Electric Urn - icon

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals