DELL Networking C150 Systems Chassis Based Switches User Guide

June 17, 2024
Dell

Dell Networking
C150 and C300 Systems
Quick Start Guide
Regulatory Model:
C150/C300

Networking C150 Systems Chassis Based Switches

Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
If you purchased a Dell n Series computer, any references in this publication to Microsoft Windows operating systems are not applicable.

Information in this publication is subject to change without notice.
© 2013 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, KACE™, FlexAddress™ and Vostro™ are trademarks of Dell Inc. Intel”, Pentium”, Xeon®, Core™ and Celeron” are registered trademarks of Intel Corporation in the U.S. and other countries. AMD” isa registered trademark and AMD Opteron™, AMD Phenom™, and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows”, Windows Server™, MS-DOS and Windows Vista © are either trademarks or registered trademarks of Microsoft C orporation in the United States and/or other countries. Red Hat Enterprise Linux” and Enterprise Linux™ are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® is a registered _ trademark and SUSE ™ is a trademark of Novell Inc. in the United States and other countries. Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Citrix”, Xen”, XenServer” and XenMotion™ are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware™, Virtual SMP”, vMotion™, vCenter™, and vSphere™ are registered trademarks or trademarks of VMWare, Inc. in the United States or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Regulatory Model: C150/C300
2013-11 P/NOJVTD9 Rev. AOl

About this Guide

This document is intended as a Quick Start Guide to get new systems up and running and ready for configuration. For complete installation and configuration information, refer to the following documents:

Documentation C150 C300
Hardware installation and power-up instructions Installing and Maintaining
the C150 System Installing and Maintaining the C300 System
Software configuration FTOS Configuration Guide FTOS Configuration Guide
Command line interface FTOS Command Line Reference Guide FTOS Command Line

Reference Guide
Latest updates| FTOS Release Notes for Cseries| FTOS Release Notes for Cseries

Installing the Hardware

This guide assumes all site preparation has been performed before installing the chassis.
Installing the Chassis
To install the C150/300 chassis, Dell Networking recommends that you complete the installation procedures in the order presented below.
NOTE: Unless stated otherwise, the installation instructions below apply to both the C150 and C300 chassis.
Always handle the system and its components with care. Avoid dropping the switch or its field replaceable units.
CAUTION: Always wear an ESD-preventive wrist or heel ground strap when handling the chassis and its components. As with all electrical devices of this type, take all necessary safety precautions to prevent injury when installing this system. Electrostatic discharge (ESD) damage can occur if components are mishandled.

Installing the Chassis in a Two-Post Rack
WARNING: Use an equipment lift or pallet jack when lifting or moving the chassis. Install the chassis into the rack before inserting chassis components.
Lift the C150/300 chassis only from the bottom. Lifting by the chassis shelves or power supply openings might damage the chassis.
WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:

  • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
  • When mounting this unit in a partially filled rack, load the rack from thebottom to the top with the heaviest component at the bottom of the rack.
  • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.

Follow these steps to install the chassis into a 19-inch equipment rack:

Step Task
1 Determine the chassis mounting location in the equipment rack.
2 Orient the bar with the arrows pointing upward. The smooth side of the bar

should face outward.
3| Attach the bar to the equipment rack brackets using the mounting screws provided by the rack manufacturer.
4| Use an equipment lift to align the chassis rack-mount holes with the equipment rack holes, and situate the chassis on top of the equipment rack bar.
5| Insert screws (provided with your rack) through the chassis rackmounting bracket and into the equipment rack,
and tighten them.
Rack Mounting the C150 Chassis

Installing Power Modules
CAUTION: Do not install the Power Supply 1200W-AC and Power Supply 1600W- AC in the same chassis. The line cards will power down and data may be lost.
If there is a failure in the power supply, it must be replaced. Power supplies are not field serviceable.
The C150 has six power supply slots at the front-bottom of the chassis. The C300 has eight power supply slots at the front-bottom of the chassis. The slots accept either AC Power Supplies (PSUs).
AC Power Supplies

  • There are two types of power supplies: Power Supply 1200W-AC and Power Supply 1600W-AC. The minimum and the redundant power supplies required to operate is listed in the table below. Dell Networking recommends the redundancy configuration.
    | | Voltage| Minimum PSUs| Minimum with
    Redundant PSUs
    ---|---|---|---|---
    C150| Power Supply 1200W
    AC/Power Supply 1600W-AC| 100-120 200-240| 1 1| 2
    2
    C300| Power Supply 1200W
    AC/Power Supply 1600W-AC
    Power Supply 1200W
    AC Power Supply 1600W-AC| 100-120
    200-240
    200-240| 2
    2
    1| 3
    3
    2
  • To protect against high-voltage shock, install a power supply blank on all unused power supply slots.
  • Connect the AC power supply to the appropriate branch circuit protection as defined by local electrical codes.
  • Verify that the remote power source complies with the system input power specifications.

WARNING: Use only the AC power cord supplied with the AC power supply.
Do not supply power to your system until the power supplies and fan tray are installed, and RPMs and line cards have been installed.
WARNING: This product relies on the building’s installation for short- circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors).
WARNING: The C300 does not have a main disconnect device installed. It is the responsibility of the installer to provide a suitable disconnecting device in the building installation and ensure that it is located/installed near the equipment and is easily accessible.
WARNING: The C300 and C150 operates in either of two voltage ranges. The different power supply configuration supported is listed in the table below. As a safety precaution, do not install more than the recommended maximum number of PSUs (given by the table below), as this causes high leakage current. Install blank panels in all unused PSU slots.

| Voltage| Frequency| Maximum PSUs
---|---|---|---
C150| 100-120
200-240| 50/60Hz
50/60Hz| 5 primary + 1 redundant
5 primary + 1 redundant
C300| 100-120
200-240| 50/60Hz
50/60Hz| 7 primary + 1 redundant
7 primary + 1 redundant
Step| Task
---|---
1| Verify the switch is in the OFF (left) position.
2| Secure the retaining latch in the unlatched position by tightening the screw into the threaded hole.
3| Slide the power supply into the top left-most power supply slot.
Dell Networking recommends installing power supplies starting from the left side, top row of the chassis, leaving no blank slots between units.
4| Lower the retaining latch, and tighten it into place.
5| Plug the AC power cord into the power receptacle in the face of the power supply.
6| Plug the power cord into an AC power outlet.

NOTE: The higher power of PoE+ (30W/port) is available only with Power Supply 1600W-AC and the PoE+ line card. When using PoE line card or PoE+ line card and Power Supply 1200W-AC, only 15.4W/port power is available. The maximum power per port is listed in the table below.

| Power Supply 1200W-AC| Power Supply 1600W-AC at  lowline (100-120V)| Power Supply 1600W-AC  at
highline (200-240V)
---|---|---|---
PoE linecard| 15.4W/port| 15.4W/port| 15.4W/port
PoE+ linecard| 15.4W/port| 30W/port| 30W/port

Installing RPMs and Line Cards
The C150 system accommodates four Line Cards and two Route Processor Modules (RPMs).
The C300 System accommodates eight line cards and two Route Processor Modules (RPMs).
RPMs
The C-Series system requires at least one Route Processor Module (RPM); two are recommended.

  • One RPM provides 48 Gigabits of bandwidth to each line card.

  • Two RPMs provides 96 Gigabits of bandwidth to each line card.

  • Blanks are required in empty slots to control airflow for adequate system cooling, personal safety, and EMI containment during operation.
    All chassis slots must be installed with operational modules or blanks. Always replace cards and blank panels immediately.

  • The blank panels for RPMs and line cards are different sizes (RPM blanks are smaller); be sure that blank panels are installed in the correct slots.

  • RPMs are hot-swappable. High Availability is supported.

  • If your system contains two RPMs, both RPMs must have the same software image.

  • RPMs are interchangable between the C300 and the C150 only if they are running FTOS version 7.6.1.0 or later.

CAUTION: RPMs are designed to be installed in either the R0 or R1 slot. Do not force RPMs into line cards slots. RPMs are keyed differently than line cards to prevent improper installation.
Line Cards
Line cards are hot-swappable. Any line card can be inserted into any line card slot. On the C150, line card slots are numbered 0 to 3. On the C300, Line card slots are labeled 0 to 7. The slot numbering labels can be seen when the fan tray is installed.

  • The LC-CB-GE-48P and LC-CB-10GE-8P line cards are interchangeable between the C300 and C150 only if the chassis is running FTOS version 7.6.1.0 or later.
  • Blanks are required in empty slots to control airflow for adequate system cooling, personal safety, and EMI containment during operation. All chassis slots must be installed with operational modules or blanks. Always replace cards and blank panels immediately.

Installing RPMs and Line Cards
WARNING:
Always wear an ESD-preventive wrist or foot-heel ground strap when handling RPMs or line cards. Place RPMs and line cards on an antistatic surface when they are not installed. Electrostatic discharge (ESD) damage can occur when components are mishandled.
CAUTION: Unlock the levers before inserting the line card into the chassis.
Fully engage the locking mechanism after the card has been inserted; not doing so might damage the card below it when that lower card is inserted.
NOTE: The fan tray face panel has slot number markings for the RPMs and line cards. Insert the fan tray before the line cards to simplify RPM and line card installation.

Step Task
1 Extend the left and right card levers by first pressing gently down on the

thumb tabs in the ejector levers and then pulling the ejector levers simultaneously until they are in the open position.
2| Hold the card assembly by the metal carrier edges. Avoid touching the printed circuit board and connector pins.
3| Align the card with the guide, and gently slide it into any line card slot until the card is about halfway into the slot.
NOTE: Use the markings on the fan tray to determine which slots are for the RPMs and which are for the line cards.
4| Continue sliding the card until you feel the connectors engage with the chassis backplane.
5| Rotate the levers toward the card to seat the backplane connectors and line card in place. Push on the knurled section of the levers until the thumb tabs pop up and lock the unit in place.
  CAUTION: Installing a card without fully engaging the locking mechanism might damage the EMI seal on the card below it when that card is inserted.
6| Install a blank panel in all slots that do not have a card, and secure it with the screws provided.

Installing the Fan Tray
The C-Series chassis contains one field-replaceable fan tray. There are two types of fan tray that may be installed: one contains six fans that run at varying speeds depending on system temperature; the other one contains six fans that run at a constant speed. For both types of trays, air flows through the system toward the fans (right to left) and is exhausted on fan-side of the chassis. The fan tray is accessible from the front of the chassis.
WARNING: To ensure proper temperature and airflow control, the fan tray must always be installed and operating properly.
NOTE: The system does not have an air filter so take special care in making sure that the installation site and the chassis itself are cleaned regularly.

Step Task
1 Slide the fan tray into the fan slot.
2 Gently push on the front of the tray until it stops. The fan tray should be

flush with the chassis.
3| Use a #2 Phillips screwdriver to secure the fan tray into place by tightening the screws at the top and bottom of the fan tray.

NOTE: The fan tray LED will remain lit when the chassis is powered up and the fan tray is functioning properly.
Power Up Sequence
Before you supply power to the chassis, Dell Networking recommends that you re-inspect your equipment rack and chassis.
CAUTION: Never operate the system without a fan tray.
To supply power to the system:

Step Task
1 Verify that the power source complies with the system input power

requirements.
2| Energize the remote power source or outlet.
3| On the C150, toggle the switch on the AC power supplies to the ON (right) position.
On the C300, toggle the switch on the AC power supplies to the ON (top) position.
4| The power supply LEDs should be green. If these LEDs are not lit green:
• Check that the unit is properly installed.
• Verify the power source.
• If the power supply cannot be verified, power off all modules and replace the unit.
5| The fan tray LED should be green (online). You should be able to hear the air flowing through the chassis. If the fans are not operating properly
or air is not flowing through the chassis:
• Power off all power supplies.
• Verify that the fan tray is properly installed.
• If the fan tray LED remains unlit, power down the unit, and replace the fan tray.

After you supply power to the system, the following should occur:

  • The fan tray should be operating.
  • The green (online) fan tray, RPM, and line card LEDs should be lit and remain lit as long as the system is receiving power and is operational.

When you supply power to the chassis, the system performs a series of power-on self tests. RPM and line card LEDs blink as the diagnostic programs run. No user interaction is required at this point. Observe the process on your console monitor. When the boot process is complete, the card LEDs remain online (green) and the console monitor displays the Command Line Interface (CLI) prompt.

Specifications

Chassis Physical Design

Parameter C150 Specifications C300 Specifications
Height 15.7 inches (39.88 cm) 22.7 inches (57.66 cm)
Width 17.5 inches (44.45 cm) 17.4 inches (37.58 cm)
Depth 15.3 inches (38.86 cm) 14.4 inches (44.20 cm)
Chassis weight 38 lbs (17.24 kg) with factory installed components
86.63 lbs (39.29 kg) fully loaded 55 lbs (24.95 kg) with factory installed

components
152.27 lbs (69.07 kg) fully loaded

Environmental Parameters

Parameter C150 Specifications C300 Specifications
Temperature -40° to 158°F (-40°C to 70°C)
(storage temperature) -40° to 158°F (-40°C to 70°C)

(storage temperature)
Relative humidity| 5 to 95% (non-condensing)| 5 to 95% (non-condensing)

AC Power Requirements
Power Supply 1600W-AC

Parameter C150 Specifications C300 Specifications
Nominal input voltage 100-240 V 50/60 Hz 100-240 VAC 50/60 Hz

Maximum AC Power Supply Input Current (Based on 1200 W
output for 100/120 V and 1600 W output 200/240 V lines)| 14 A @ 100 V per AC Power Supply
11 A @ 120 V per AC Power Supply
9 A @ 200 V per AC Power Supply
7 A @ 240 V per AC Power Supply| 14 A @ 100 V per AC Power Supply
11 A @ 120 VAC per AC Power Supply
9 A @ 200 VAC per AC Power Supply
7 A @ 240 VAC per AC Power Supply
Maximum System| 6,897 KVA @ 100/120 V| 9,667 KVA @ 100/120 V
Power Input| 7,315 KVA @ 200/240 V| 12,596 KVA @ 200/240 V
Parameter| C150 Specifications| C300 Specifications
---|---|---
Maximum power consumption| 1,647 W @ 100/120 V
1,555 W @ 200/240 V| 2,707 W @ 100/120 V
2,726 W @ 200/240 V
Maximum Thermal
Output at 100/120 V| 5,618 BTU/hour| 9,235 BTU/hour
Maximum Thermal
Output at 200/240 V| 5,304 BTU/hour| 9,299 BTU/hour

Power Supply 1200W-AC

Parameter C150 Specifications C300 Specifications
Nominal input voltage 100-240 V 50/60 Hz 100-240 VAC 50/60 Hz

Maximum AC Power Supply Input Current (Based on 1200 W
output for both 100/120 V and 200/240 V lines)| 14 A @ 100 V per AC Power Supply
11 A @ 120 V per AC Power Supply
7 A @ 200 V per AC Power Supply
6 A @ 240 V per AC Power Supply| 14 A @ 100 V per AC Power Supply
11 A @ 120 VAC per AC Power Supply
7 A @ 200 VAC per AC Power Supply
6 A @ 240 VAC per AC Power Supply
Maximum System Power Input| 4,261 KVA @ 100/120 V
4,165 KVA @ 200/240 V| 8,274 KVA @ 100/120 V
8,088 KVA @ 200/240 V
Maximum power consumption| 1,304 W @ 100/120 V
1,208 W @ 200/240 V| 2,361 W @ 100/120 V
2,175 W @ 200/240 V
Maximum Thermal
Output at 100/120 V| 4,449 BTU/hour| 8,055 BTU/hour
Maximum Thermal
Output at 200/240 V| 4,122 BTU/hour| 7,420 BTU/hour

Installing the Software

Navigating CLI Modes
The FTOS prompt changes to indicate the CLI mode. You must move linearly through the command modes, with the exception of the end command which takes you directly to EXEC Privilege mode; the exit command moves you up one command mode level.
Console Access
The console port is an asynchronous serial port. If you connect a device to these ports, it must be capable of asynchronous transmission.

Step Task
1 Install an RJ-45 copper cable into the console port. Use a rollover cable

to connect the C150 or C300 console port to a terminal server.
2| Connect the other end of the cable to the DTE terminal server.
3| Your terminal or terminal emulation mode must be set to VT100 with the following settings:
9600 baud rate (To avoid autobaud input, the default is set to a 9600 BPS.)
No parity 8 data bits 1 stop bit Window Terminal Emulator option set to NO 24 lines X 80 characters No flow control

Cable and Adapter Pin Assignments
Use the console port on the RPM of the C150 or C300 to connect to a terminal port, PC serial port, or a terminal server to configure and monitor your system.
An RJ-45 Ethernet cable is required to connect to the Ethernet port.
The console port is an RJ-45 and the pinouts are listed in Table 2-1.
Table 2-1. Pin Assignments for Console Port (RJ-45)

Pin Signal Input/Output
1 NC (unused
2 DTR Output
3 TxD Output
4 GND
5 GND
6 RxD Input
7 DSR Input
8 NC (unused

Accessing the Console with a DB-9 Adapter
You can connect to the console using an RJ-45 to RJ-45 rollover cable and an RJ-45 to DB-9 female DTE adapter (labeled “TERMINAL”) to a terminal server (for example, PC).
Table 2-2. Pin Assignments Between the Console and a DTE Terminal Server

Console Port| RJ-45 to RJ-45| Rollover Cable| RJ-45 to DB-9 Adapter| Terminal Server Device
---|---|---|---|---
Signal| RJ-45 Pinout| RJ-45 Pinout| DB-9 Pin| Signal
RTS| 1| 8| 8| CTS
DTR| 2| 7| 6| DSR
TxD| 3| 6| 2| RxD
GND| 4| 5| 5| GND

Table 2-2. Pin Assignments Between the Console and a DTE Terminal Server

Console Port| RJ-45 to RJ-45| Rollover Cable| RJ-45 to DB-9 Adapter| Terminal Server Device
---|---|---|---|---
Signal| RJ-45 Pinout| RJ-45 Pinout| DB-9 Pin| Signal
GND| 6| 4| 5| GND
TxD| 5| 3| 3| TxD
DSR| 7| 2| 4| DTR
CTS| 8| 1| 7| RTS

Accessing the Console with a DB-25 Adapter
You can connect to the console port using an RJ-45 to RJ-45 rollover cable and an RJ-45 to a DB-25 female DTE adapter.
Table 2-3. Pin Assignments Between the Console and a DTE Terminal Server

Console Port| RJ-45 to RJ-45| Rollover Cable| RJ-45 to DB-25 Modem Adapter| Terminal  Server Device
---|---|---|---|---
Signal| RJ-45 Pinout| RJ-45 Pinout| DB-25 Pinout| Signal
RTS| 1| 8| 5| CTS
DTR| 2| 7| 6| DSR
TxD| 3| 6| 3| RxD
GND| 4| 5| 7| GND
GND| 5| 4| 7| GND
RxD| 6| 3| 2| TxD
DSR| 7| 2| 20| DTR
CTS| 8| 1| | RTS

Default Configuration
A version of the Dell Networking Operating System (FTOS) is pre-loaded onto the chassis, however the system is not configured when you power up for the first time (except for the default host name, which is Force10). You must configure the system using the Command Line Interface (CLI).
Configure Layer 2 (Data Link) Mode
Use the switchport command in INTERFACE mode to enable Layer 2 data transmissions through an individual interface. The user cannot configure switching or Layer 2 protocols such as the spanning tree protocol on an interface unless the interface has been set to Layer 2 mode.

Step Task Command Syntax Command Mode
1 Enable the interface. no shutdown INTERFACE
2 Place the interface in Layer 2
(switching) mode. switchport INTERFACE

To view the interfaces in Layer 2 mode, use the show interfaces switchport command in the EXEC mode.
Configure a Host Name
The host name appears in the prompt. The default host name is force10.

  • Host names must start with a letter and end with a letter or digit.
  • Characters within the string can be letters, digits, and hyphens.
Task Command Syntax Command Mode
Create a new host name.  hostname name CONFIGURATION

Access the System Remotely

You can configure the system to access it remotely by Telnet.
The C150 and C300 systems have a dedicated management port and a management routing table that is separate from the IP routing table.
Configuring the system for Telnet is a three-step process: Step| Task
---|---
1| Configure an IP address for the management port.
2| Configure a management route with a default gateway.
3| Configure a username and password.

Configure the Management Port IP Address
Assign IP addresses to the management ports in order to access the system remotely.
NOTE: Assign different IP addresses to each RPM’s management port.

Step Task Command Syntax Command Mode
1 Enter INTERFACE mode for the
Management port. interface ManagementEthernet
slot/port INTERFACE
2 Assign an IPv4 or IPv6 address to the interface. ip address {ipv4-address
ipv6- address}/mask CONFIGURATION
3 Enable the interface. no shutdown INTERFACE

Configure a Management Route
Define a path from the system to the network from which you are accessing the system remotely. Management routes are separate from IP routes and are only used to manage the system through the management port.

Task Command Syntax Command Mode

Configure an IPv4 or IPv6 management route to the network from which you are accessing the system.| management route {ipv4-address| ipv6-address}/mask gateway| CONFIGURATION

Configure a Username and Password
Configure a system username and password to access the system remotely.

Task Command Syntax Command Mode
Configure a username and password to access the system remotely. username

username password
[encryption-type] password| CONFIGURATION

Configure the Enable Password
The EXEC Privilege mode is accessed by the enable command. Configure a password as a basic security measure. When using a console connection, EXEC Privilege mode is unrestricted by default; it cannot be reached by a VTY connection if no password is configured. There are two types of enable passwords:

  • enable password stores the password in the running/startup configuration using a DES encryption method.
  • enable secret is stored in the running/startup configuration by using a stronger, MD5 encryption method.

Dell Networking recommends using the enable secret password.

Task Command Syntax Command Mode
Create a password to access EXEC Privilege mode. enable [password secret]
[level level] [encryption-type] password CONFIGURATION

Create a VLAN
The Default VLAN is part of the system startup configuration, and is by default, VLAN 1. You may make another VLAN the Default VLAN. The Default VLAN cannot be deleted, disabled, or configured (you cannot assign it an IP address), and only untagged interfaces can belong to it.
When an interface is configured, a switchport automatically places it in the default VLAN as an untagged interface. All switchports must belong to at least one VLAN, so to remove a switchport from the Default VLAN, you must place it as tagged or untagged in some other VLAN, or remove the switchport configuration.

Task Command Syntax Command Mode

Create a VLAN
Display all VLANs.| interface vlan vlan-id
show vlan vlan-id| CONFIGURATION
EXEC Privilege

Assign Interfaces to a VLAN
A port may either be an untagged member of a single VLAN, or a tagged member of perhaps multiple VLANs.

  • Untagged Ports — ports that do not append an 802.1Q VLAN tag to frames on egress, and do not accept tagged frames on ingress (tagged frames are dropped). Untagged ports must be connected to VLAN-unaware devices.
  • Tagged Ports — ports that append an 802.1Q tag to frames on egress, and accept only tagged frames on ingress (untagged frames are dropped). Tagged ports must be connected to VLAN-aware devices.

When you configure an enabled port as a switchport, the port is placed in the default VLAN. To remove a switchport from the default VLAN, remove the switchport configuration. To move the port to another VLAN, add it to the desired VLAN as either a tagged or untagged member.
To view just the interfaces that are in Layer 2 mode, enter the show interfaces switchport command in the EXEC mode.

Step Task Command Syntax Command Mode
1 Assign a switchport to a VLAN. [tagged untagged] interface

VLAN
2| Display all switchports and the VLANs of which they are members.| show vlan| EXEC Privilege

Assign an IP address to a VLAN
NOTE: An IP address cannot be assigned to the Default VLAN, which, by default, is VLAN 1. To assign another VLAN ID to the Default VLAN, use the default vlan-id vlan-id command.

Task Command Syntax Command Mode

Configure an IP address and mask on
the interface.| ip address ip-address mask [secondary]| INTERFACE

Connecting the Chassis to the Network
Once you have completed the hardware installation and software configuration, you can connect to your company network by following your company’s cabling requirements.

Printed in the U.S.A.
www.dell.com | support.dell.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals