FASELASE 2D Lidar S5 Industrial Obstacle Sensor User Manual
- June 17, 2024
- FASELASE
Table of Contents
Industrial 2D LiDAR
S5
USER MANUAL
(Version V8.01.8)
For more info & supports, please visit http://www.top1sensor.com
Specifications
Items | Parameters |
---|---|
Scanning range I | 0.15-5m@I O%, 3m@2% |
Measurement error 1 | ±3cm@5m@l 2Hz |
Scanning angle range | 360. |
Angle resolution | 0.3· |
Scanning frequency 3 | 12Hz |
Input & Outpu t Interface | 1/0 output:3xl/O NPN: 1/0 input:2x l/O NPN |
Interface of setting | USB |
Mini mum distance resolution | I cm |
Laser source | Laser diode 905nm, ImW; |
Class I Laser Eye Safety Requirements
Power supply| DC 12-36V, Starting current> I.SA (@12V),
Power consumption<4W
Volume| 777763 mm
Starting time| Sseconds
Operating temperature range| -1o c-+so’C
Storage temperature range| -2o·c- +1o’C
Protection level| IP66
Weight| 310 g
Table 1: Specification
Notes:
-
The device can measure up to3 meters when the reflectivity of the target is 2%;
The device can measure up to 5 meters when the reflectivity of the target is 10%. -
The measurement accuracy is ±3cm when the measurement range achieves 5 m and scanning frequency is 12Hz.
-
The default rotating speed is 12 revolutions per second.
Dimensional drawing
The operating mode
3.1 Fixed device
Fixed the base of the sensor with 4-M3*10 screws
3.2 Connect the device
3.2.1 Wiring
Pins | Function | Color | Description |
---|---|---|---|
1 | +12±15% | Red | DC power supply +12V |
2 | GND | White | DC power ground |
3 | Tx | Yellow | External connection TTL Rx |
4 | Rx | Green | External connection TTL Tx |
5 | GND | Black | Connect to internal GND |
6 | I/O_1 Out | Orange | NPN output 1 |
7 | I/O_2 Out | Brown | NPN output 2 |
8 | I/O_3 Out | Gray | NPN output 3 |
9 | I/O_1 In | Purple | NPN input 1 |
10 | I/O_2 In | Blue | NPN input 2 |
Table 2: Instruction of pins signal
Group | Input in |
---|---|
I/O_1 In | I/O_2 In |
Group 1 | L (low level) |
Group 2 | H (high level) |
Group 3 | L (low level) |
Group 4 (default) | H (high level) |
Table 3: input correspondence table
Note: the maximum external voltage of I/O is 36V, and the maximum output current is 200mA. If the current exceeds this range, the device will be damaged.
3.2.2 Power supply
Under normal circumstances, the power supply is 12V~36V. The current needs
more than 1.5A (rated 12V) when the device is starting. Send the operation
instruction to device in the monitoring software, if the device doesn‟t
respond accordingly, first check whether the voltage/current of the device is
within the required range. If the starting current is too low, the device
cannot start normally; if the voltage/current is too high, the device element
will be burned out.
3.2.3 Drive installation and operation
Visit http://www.top1sensor.com/ to download product files of the
corresponding model. Install the serial port driver after decompressing the
software. Usually, you need to separately insert the conversion board into the
USB port of the computer separately without powering on the device, then
proceed to the next step after the serial port is successfully installed.
Before power on the . Lidar, USB must be connected to the host computer. If
power on the Lidar first and then connect the USB to computer, the mouse may
be uncontrolled. Please pay attention to the operation sequence. After the
installation is successful, run “FaseLase LiDAR Point Cloud Data Acquisition
and Analysis System V8.02.exe” to work normally.
Data acquisition
Run “FaseLase LiDAR point cloud data acquisition and analysis system
V8.02.exe”program, then pop-up the communication setting window (as shown
Figure 6). The setup steps as follow,
① Select Device: S5,
② Select Serial Port:COM4,(the serial port can automatically be identified by
computer)
③ Select Band Rate: 921600, it is not be modified.
Click „Yes‟ to enter the monitoring window (as shown Fig 7).
Stop bit 1, data bit 8, parity none.
Click protect area button , pop-up protect area interface(as shown Figure 8)
① Set up voltage required for the current I/O input group;
② Select the input group through the drop-down menu;
(3) The number of current group and the total number of areas of all groups;
(4) The group where the current liDAR internal scanning detection is located;
Select the group to be set through the drop-down menu in the setting window.
There are 4 groups to choose from. Each group supports three different
protection areas. For example, numbers 1-3 refer to protection area 3 in group
- Read device area: read the protection area information written in the current
liDAR Save all to device: information about each protection area of the 4
groups is written into the liDAR
Delete all: delete all information of 12 groups
Save selected area to device: write the currently selected information of the protection area into the liDAR, other numbers remain unchanged;
As shown in the figure 9, “current input Group is Group4”, the connected
voltage state of the liDAR IO_In1 and IO_In2 is high. In the wiring state of
IO_In, the liDAR calls three region protection areas in the fourth group. The
blue line in the interface is the effect diagram of data point cloud actually
measured by LiDAR. Protect 3 is a polygon with 4 vertices and 46 data points
(the largest quadrilateral in the figure is the protect 3, it is expressed as
“3:46″), it meets the condition of sensitivity 5 (Sensitivity 5 means that the
trigger condition is met if there are at least 5 data points in the area), it
triggers the output of low level of IO_Out3 (originally, IO_Out3 was always
high level, but changed to low level output after meeting the trigger
condition). At the same time, all the edges of the figure of protect 3 changed
from green to red, the font of ” Protect 3″ also changed from green to red,
and the front panel indicator light of the lidar changed to the corresponding
state. Similarly, polygons in protect 1 and protect 2 have no data points,
which does not meet the trigger condition of sensitivity 5. Therefore, high
level signals are output at IO_Out1 and IO_OUT2 respectively.
Click the STOP button to stop the motor before modifying the Lidar Settings.
Otherwise, communication failure will occur. After pausing, click the “read
all areas” button first (the
graphics saved by the software may be inconsistent with the graphics stored by
the Lidar), so that the graphics saved in the Lidar can overwrite the graphics
cached in the software. For example, if you want to set image of protect 1in
Group 4, click the left mouse button in column 4-1 and move the mouse to the
right grid diagram. Click the left mouse button at any position to set the
first coordinate point. As long as the graph is not closed, click the left
mouse button can add a new point every time and automatically connect with the
previous point. After each click, the coordinate of the point will be
displayed on the right side of the point. Click the left mouse button on the
edge of the closed graph to add coordinates, drag to change the graph,
currently supports up to five vertices.
Right-click the mouse at the coordinate point to pop up the option box. By editing the status of the point, you can also choose to edit area, delete point, delete area, or delete group, delete all at once. “load file ” and “save as file” can save 12 set areas in 4 groups in files with ini suffixes, making it easier to load files directly next time.
In the edit mode, you can fine-tune the position of the coordinate point by
input the specific coordinate value, you can also set the level mode of the
output of the protection area in the
triggered state (output high level or set to output low level when breaking
into the region protection area), you can also choose whether the protection
area is polygon or sector.
Sensitivity refers to the threshold of the number of trigger points in the
area protection, for example, the sensitivity of area protection 1 is 5, this
protect area will not trigger the output
level change when there are only 4 points in area protection 1. The selected
area protection will turn into a blue line, and the coordinates of the points
will be displayed. After all Settings are completed, click “save selected
area” or “save all to device” and click to run, and the Lidar is operating in
the newly defined area.
Standard and optional accessories
No. | Items | Qty | Remarks |
---|---|---|---|
1 | S5 | 1 pc | Including a 0.8m |
long data cable
2| TTL to USB| 1 pc|
3| DC +12V power adapter| 1 pc| Optional
4| Protective cover| 1 pc| Optional
5| Mounting bracket| 1 pc| Optional
Table 4: list of configurations