SAVE THESE INSTRUCTIONS
This manual contains important instructions for the OutBack PSX-240 Autotransformer. All of the AC wiring to the circuit breakers terminals is to be torqued according to the torque specs in the Mechanical Installation section of this manual. Wiring to these terminals must meet the requirements of the National Electric Code (NEC). The terminals will accept up to 10AWG. Use copper conductors only with insulation rated for 75˚ C. See the AC WIRING CONNECTIONS section of this manual for more information.
- For equipment grounding hook up, see the system configuration sections in this manual. This product is intended to be installed as part of a permanently grounded electrical system per the NEC.
- Installation must be performed by a licensed installer familiar with local and national wiring codes.
- The equipment ground on the PSX-240 is marked with this symbol:
GENERAL PRECAUTIONS
- Before using the PSX-240, read all instructions and cautionary markings on (1) the PSX-240 and (2) all appropriate sections of this installation and operation manual.
- The PSX-240 is approved for indoor mounting only in any position.
- Do not disassemble the PSX-240. Refer servicing to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire. To reduce risk of electric shock, disconnect all wiring before attempting any maintenance or cleaning. Turning off the PSX-240 may not reduce this risk.
- No terminals or lugs are required for hook-up of the AC wiring. AC wiring must be copper wire and rated for 75°C or higher.
ADDITIONAL NOTICES
- For instructions on mounting, see the Mechanical Installation section of this manual.
- All installations must comply with local and national electrical codes and standards.
- All installations must comply with local and national codes for structural installation.
Outback Power PSX-240 User’s Guide
Introduction
Congratulations on your purchase of the PSX-240 autotransformer. Please take time to read this basic instruction sheet covering common applications.
Basic Description
The PSX-240 is an autotransformer containing, in it’s raw form, two sets of windings in a 1:1 ratio.
Two 25 Amp AC breakers provide the input/output connection points for the unit. Below is the schematic for the internal wiring of the PSX-240
Outback Power PSX-240 User’s Guide
Configuration
Two basic configurations exist for the PSX-240 with the factory wiring arrangement.
- 120VAC to 240VAC step up transformer
- 240VAC to 120VAC step down/balancing transformer
Step-Up Transformer Configuration
In the step up transformer configuration, Hot leg L1 is connected to one of the 25A breakers on the PSX-240. 240VAC power is available across the two 25A breakers.
Outback Power PSX-240 User’s Guide
Step Down/Balancing Configuration
The step-down configuration for the PSX-240 is essentially the opposite of the step-up configuration. L1 and L2 (240VAC) power is applied to the 25A breakers of the PSX-240. 120VAC is then available from either L1 or L2 to system neutral. This configuration inherently provides balancing for the 240VAC source.
Outback Power PSX-240 User’s Guide
Mechanical Installation of the PSX-240
NOTICE! Please read and understand the IMPORTANT SAFETY INSTRUCTIONS
section at the front of this manual for before proceeding.
The PSX240 may be installed on a vertical or horizontal surface utilizing the
four mounting holes on the back of the unit with #10×2” screws.
AC Wiring Torque Specs
Torque specs for the 25A breakers are printed on the side of the breaker housing. The correct torque for the breakers is:
- 20 in-lbs
The torque for the screws in the neutral bus bar varies depending on the hole in which the wiring is installed. The larger of the two hole sizes in the neutral bar is the MAIN HOLE, the smaller holes are the TAP HOLES.
Main Holes | Tap Holes |
---|---|
1/0 to 14 AWG – 50 in-lbs | #6-#14AWG- 40 in-lbs |
WARRANTY
OutBack Power Systems
Two-Year Limited Warranty
OutBack Power Systems Inc. warrants that the products it manufactures will be
free from defects in materials and workmanship for a period of two (2) years
subject to the conditions set forth below. The limited warranty is extended to
the original user and is transferable. The limited warranty term begins on the
date of invoice to the original user of the product. The limited warranty does
not apply to any product or part thereof damaged by a) alteration or
disassembly, b) accident or abuse, c) corrosion, d) lightning, e) reverse
polarity, f) repair or service provided by an unauthorized repair facility, g)
operation or installation contrary to instructions pertaining to the product.
OutBack Power Systems’ liability for any defective product or any part thereof
shall be limited to the repair or replacement of the product, at OutBack Power
Systems’ discretion. OutBack Power Systems does not warrant or guarantee the
workmanship performed by any person or firm installing its products. THIS
LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER
RIGHTS THAT VARY FROM STATE TO STATE (OR JURISDICTION TO JURISDICTION).
OUTBACK POWER SYSTEMS’ RESPONSIBILITY FOR MALFUNCTIONS AND DEFECTS IN HARDWARE
IS LIMITED TO REPAIR AND REPLACEMENT AS SET FORTH IN THIS LIMITED WARRANTY
STATEMENT. ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT
NOT LIMITED TO ANY IMPLIED WARRANTIES OF AND CONDITIONS OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE LIMITED
WARRANTY PERIOD SET FORTH ABOVE AND NO WARRANTIES, WHETHER EXPRESS OR IMPLIED,
WILL APPLY AFTER SUCH PERIOD. SOME STATES (OR JURISDICTIONS) DO NOT ALLOW
LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY
NOT APPLY TO YOU.
OUTBACK POWER SYSTEMS DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES SET FORTH
IN THIS LIMITED WARRANTY STATEMENT OR LIABILITY FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION ANY LIABILITY FOR PRODUCTS
NOT BEING AVAILABLE FOR USE. SOME STATES (OR JURISDICTIONS) DO NOT ALLOW THE
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE
EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU.
During the two year period beginning on the invoice date, OutBack Power
Systems will repair or replace products covered under this limited warranty
that are returned to OutBack Power Systems’ facility or to an OutBack Power
Systems authorized repair facility, or that are repaired on site by an OutBack
Power Systems authorized repair technician. To request limited warranty
service, you must contact OutBack Power Systems at
360-435-6030 within the limited
warranty period. If limited warranty service is required, OutBack Power
Systems will issue a Return Material Authorization (RMA) Number. Mark the
outside of the package with the RMA number and include a copy of the purchase
invoice in the package. You must ship the products back to OutBack Power
Systems in their original or equivalent packaging, prepay shipping charges,
and insure the shipment or accept the risk of loss or damage during shipment.
OutBack Power Systems will ship the repaired or replacement products to you
freight prepaid if you use an address in the continental United States, where
applicable. Shipments to other locations will be made freight collect
REGISTRATION
Your purchase of an OutBack Power Systems product is an important investment. Registering your products will help us maintain the standard of excellence you expect from us in terms of performance, quality and reliability. Please take a moment to register and provide us with some important information.
- Name:
- Address:
- City, State, Zip Code, Country: ___
- Telephone Number: __
- E-Mail: ____
- Sold by: ___
- Installer: ___
- Purchase Date: _____
- Model Number:____
- Serial Number: __
- Circle all that apply:
- Off-Grid Installation Residential Installation
- North America Location Utility Connected Installation
- Commercial Installation Other ____
Mail to: Attn: Warranty Registration
- Outback Power Systems 19009 62nd Ave. NE Arlington, WA 98223 PSX-240 User’s Guide
- P/N: 900-0043-1
- Rev. A – Released 4/25/2005
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>