OutBack Power OGHESS8015A Mojave Energy Storage System User Manual

June 12, 2024
OutBack POWER

OutBack Power OGHESS8015A Mojave Energy Storage System

OutBack Power OGHESS8015A Mojave Energy Storage System

Dimension

Dimension

  • Be ready for anything with off-grid capability
  • Easily start motors and compressors commonly found in freezers and HVAC systems, outpacing other energy storage systems
  • Seamlessly AC-couple with UL 1741-SA listed grid-tied inverters up to 8kW for easy addition to existing solar PV systems
  • Takes up just two square feet of floor space and fits between most garage doors and their side walls
  • Connect to the intuitive user interface via integrated Wi-Fi hotspot and a smartphone, tablet or laptop
  • Access OPTICS RE™ system monitoring via Ethernet or Wi-Fi internet connection
  • Easily add a generator or other secondary AC source
  • Quickly and easily install with mounting plate and roomy integrated wiring compartment
  • Financing options available: outbackpower.com/financing

The Mojave™ platform combines the latest power electronics and control technology with the old-school muscle and practical features that define OutBack Power™.
The Mojave™ Energy Storage System (ESS) continues the impressive legacy of robust off-grid and grid-hybrid performance for which OutBack Power’s FX, FXR and Radian platforms are well known. But it doesn’t stop there. The Mojave™ ESS includes the battery and integrated controls and communications for faster, clutter-free installation.
The Mojave™ Lithium ESS comes ready to AC-couple with most gridtied inverters. It’s the easy way to add the economic and resilience benefits of energy storage to existing residential PV systems.
On-grid or off, be ready for anything.

Specifications

Model: OGHESS8015A

Grid Interactivity

Supported Operating Modes:| Immediate battery backup power, grid support (UL 1741 SA), net metering, non-export, off-grid, maximum independence
Islanding Protection:| Yes – IEEE 1547 compliant
Supported Interconnection Standards:| IEEE 1547-2003, IEEE 1547.1-2005
Grid Interconnection Standards:| HECO Rule 14H v2.0 SRD, CA Rule 21b Phase 1, 2, and Functions 1 and 8 of Phase 3, and PREPA
External Transfer Switch:| Mojave™ inverter utilizes built-in transfer switch, no external Auto Transfer Switch (ATS) required
Inverter

AC Voltage:| 120/240VAC (split-phase)
AC Frequency:| 60Hz
Max Peak/Continuous AC Output Power without Mojave or EnergyCell Battery:| 10000VA / 8000VA (derate above 40°C), compatible EnerSys®  battery required
Max Peak/Continuous AC Output Power without External Transfer Switch:| 10000VA / 8000VA (derate above 40°C), compatible EnerSys®  battery required
Peak Motor Starting Current:| 60A at 240VAC (14.4kVA) for 32ms,

60A continues at lower voltage until motor starts

Max Peak/Continuous Output Current:| 42A / 34A
Total Harmonic Distortion:| Typical: <2% | Max: <5%
Power Factor at Rated Power:| 1
Idle Power:| Invert Mode, No Load: 100W | Idle: 10W
AC Coupling:| Up to 8kW
Ground Fault Isolation Detection:| Included / yes
Charge Battery from AC:| Yes
Maximum Split Phase Imbalance:| 3.960kVA (33A at 120V)
Battery

Capacity Nameplate/Usable:| 14.8kWh / 11.8kWh usable (80% of 14.8kWh)
Reserve and Recovery Battery Capacity:| 3kWh of 14.8kWh
Nominal Battery Voltage:| 48 to 55.9V
Battery Voltage Range:| 40 to 64VDC
Max Charging Current Peak/Continuous:| 200A
Max Discharge Current Peak/Continuous:| 200A
Integrated DC Disconnect Rating:| 250A
Scalability:| One Mojave™ inverter to one Mojave battery
Battery Chemistry:| Lithium Nickel Manganese Cobalt (NMC)
Battery Capacity (State of Health) at End of Warranty Period:| 80%
Resolution of Measurement of Battery Voltage:| 0.1V
Mechanical

Weight (lb/kg) :| Inverter: 133 / 60
Battery: 455 / 260
Shipping: 688 / 308
Dimensions W × H × D (in/mm) :| Inverter: 16 × 38 × 11.25 / 406 × 965 × 286
Battery: 24 × 44 × 12.25 / 610 × 1118 × 311
Shipping: 40 × 51 × 48 / 1016 × 1295 × 1219
Chassis Type:| Indoor-only, vented, NEMA 1, IP2X
Cooling:| Forced air convection
Additional Features

Listings/Certifications:| UL 1741 SA, CSA 22.2 No. 107.1, IEEE 1547-2003, IEEE 1547.1-2005
RoHS:| Yes, directive 2011/65/EU
Operating Temperature Range:| −4 to 122°F (−20 to 50°C)
Warranty Duration:| 10 years or 46Mwh
Field-Upgradable Firmware:| Yes, internet (default), local Wi-Fi, Ethernet or USB
EM Radiation Immunity:| 20V/m
Supported Communications Interfaces:| CAN with Mojave™ ESS product only
System Monitoring:| OPTICS RE™ for Mojave™ ESS connected to the internet
System Setup:| Mojave™ ESS setup page via Mojave™ Wi-Fi hotspot (computer or mobile device not provided)
Disconnect Breaker for Backup Loads:| Built-in 50A circuit breaker
Inverter Bypass Switch:| Automatic

Nominal Capability and Surge Power

Nominal Capability and Surge Power

Cumulative Energy Discharge Per Year (11.8kWh/day)

Cumulative Energy Discharge Per Year \(11.8kWh/day\)

Customer Support

World Headquarters
2366 Bernville Road
Reading, PA 19605 USA
+1 610-208-1991 / +1 800-538-3627
EnerSys EMEA

EH Europe GmbH
Baarerstrasse 18
6300 Zug Switzerland

EnerSys Asia
152 Beach Road
Gateway East Building #11-08
Singapore 189721 / +65 6431-3700

For OutBack Power™ product questions and
additional information please contact us:
Headquarters: +1 360-435-6030 | Technical Support: +1 360-618-4363
[email protected] | www.outbackpower.com

For more information visit www.enersys.com © 2022 EnerSys. All Rights Reserved. Trademarks and logos are the property 2 of EnerSys and its affiliates unless otherwise noted. Subject to revisions without prior notice. E.&O.E.


OutBack Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

OutBack POWER User Manuals

Related Manuals