TRANE TPLA0A0361EA80A Ceiling Cassette Instruction Manual
- June 17, 2024
- Trane
Table of Contents
TRANE TPLA0A0361EA80A Ceiling Cassette
Product Information
Specifications
Unit Type| Cooling Capacity| Heating Capacity| Electrical| Refrigerant Piping|
Dimensions (W x D x H)| Weight
---|---|---|---|---|---|---
CEILING CASSETTE| 36,000 BTU/H| 38,000 BTU/H| 208/230V AC| R410A| 33-1/16″ x
33-1/16″ x 11-3/4″ [840 x 840 x 298 mm]| 57 lbs. [26 kg]
Product Usage Instructions
Installation
- Make sure there is a space of at least 1/4 inch or more in the ceiling for installation.
- Ensure there is a ceiling height of 118-1/8 inches (3000mm) or more between the indoor unit and any obstacles.
- The distance between the top of the unit and the ceiling slab should be at least 70-7/8 inches (1800mm) or more from the floor.
- Connect the indoor unit to the outdoor unit using the provided terminal block.
- Install the optional parts such as the signal receiver, corner pocket vane motor, wall ceiling grille, and grille as per the instructions.
- Ensure proper wire entry for the remote controller and fresh air intake hole.
- Connect the drain hole and branch duct hole as needed.
Operation
- Use the wired remote controller (PAC-SF40RM-E) for controlling the indoor unit. A wireless remote controller cannot be used.
- Refer to the user manual for detailed instructions on using the wired remote controller.
- The I-SEE sensor corner panel needs to be set up using the remote controller for proper functioning.
- Make sure to perform regular maintenance and cleaning of the unit for optimal performance.
Frequently Asked Questions (FAQ)
Q: Can I use a wireless remote controller with this product?
- A: No, this product can only be used with the wired remote controller (PAC-SF40RM-E).
Q: What is the recommended ceiling height for installation?
- A: The recommended ceiling height is 118-1/8 inches (3000mm) or more between the indoor unit and any obstacles.
Q: What is the refrigerant used in this product?
- A: This product uses R410A refrigerant.
Q: How do I connect the indoor unit to the outdoor unit?
- A: Connect the indoor unit to the outdoor unit using the provided terminal block.
GENERAL FEATURES
- Space-efficient ductless installation
- Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency
- Airflow settings for high and low ceiling applications
- Individual vane settings for direct/indirect airflow control or variable airflow patterns
- Knockouts for outside-air intake and branch-duct run
- Filter indicator signal
- Easy-to-clean, washable filter (optional high-efficiency filter available -requires multi-function casement)
- Built-in condensate lift mechanism
- Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
- Multiple control options available:
- kumo cloud® smart device app for remote access
- Third-party interface options
- Wired or wireless controllers
Specifications | System |
---|---|
Unit Type | TPLA0A0361EA80A |
Cooling Capacity1, 3 | BTU/H |
Heating Capacity2, 3 | BTU/H |
Electrical | Voltage, Phase, Frequency |
Guaranteed Voltage Range | V AC |
Voltage: Indoor – Outdoor, S1-S2 | V AC |
Voltage: Indoor – Outdoor, S2-S3 | V DC |
Short-circuit Current Rating [SCCR] | kA |
Indoor Unit | MCA |
Fan Motor Full Load Amperage | A |
Airflow Rate at Cooling, Dry | CFM |
Airflow Rate at Cooling, Wet | CFM |
Airflow Rate at Heating, Dry | CFM |
Sound Pressure Level [Cooling] | dB[A] |
Sound Pressure Level [Heating] | dB[A] |
Drain Pipe Size | In. [mm] |
Condensate Lift Mechanism, Maximum Distance | In. [mm] |
Coating on Heat Exchanger | — |
External Finish Color | White Munsell 6.4Y 8.9/0.4 |
Unit Dimensions | W x D x H: In. [mm] |
298]
Package Dimensions| W x D x H: In. [mm]| 34-19/64 x 35-35/64 x 16-37/64 [871 x
903 x 421]
Unit Weight| Lbs. [kg]| 57 [26]
Package Weight| Lbs. [kg]| 89 [40]
Refrigerant| Type| R410A
Piping| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
- Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.
- For reference to connected capacity charts, please refer to Multi-zone Outdoor Unit Operational Performance.
INDOOR UNIT ACCESSORIES
TPLA0A0361EA80A
Control Interface | 3-Pin Connector | □ PAC-715AD |
---|---|---|
Airline ZBS Wired Blueface Principal Controller White | □ AZZBSBLUEFACECB | |
Airline ZBS Wired Blueface Principal Controller White | □ AZZBSBLUEZEROCB | |
Airline ZBS Wired Lite Controller White | □ AZZBSLITECB | |
Airline ZBS Wireless Lite Controller White | □ AZZBSLITERB | |
Airline ZBS Wireless Think Controller White | □ AZZBSTHINKRB | |
CN24 Relay Kit | □ CN24RELAY-KIT-CM3 | |
IT Extender | □ PAC-WHS01IE-E | |
Kumo station® for kumo cloud® | □ TAC-WHS01HC-E | |
Procon BACnet® and Modbus® Interface | □ PAC-UKPRC001-CN-1 | |
Remote Operation Adapter‡ | □ PAC-SF40RM-E | |
Thermostat Interface | □ PAC-US445CN-1 | |
USNAP Adapter | □ PAC-WHS01UP-E | |
Wireless Interface for Kumo cloud® | □ PAC-USWHS002-WF-2 | |
Remote Sensor | Flush Mount Remote Temperature Sensor | □ PAC-USSEN002-FM-1 |
Flush Mount Temperature Sensor | □ PAC-USSEN001-FM-1 | |
Remote Temperature Sensor | □ PAC-SE41TS-E | |
Wireless temperature and humidity sensor for Kumo cloud® | □ PAC-USWHS003-TH-1 | |
Wired Remote Controller | Deluxe Wired MA Remote Controller† | □ TAR-40MAAU |
Simple Ductless Wired Remote Controller | □ PAC-SDW01RC-1 | |
Simple MA Remote Controller† | □ TAC-YT53CRAU-J | |
Touch MA Controller† | □ TAR-CT01MAU-SB | |
Wireless Remote Controller | Kumo touch™ RedLINK™ Wireless Controller | □ MHK2 |
Lockdown bracket for remote controller | □ RCMKP1CB | |
Wireless MA Receiver | □ PAR-SR32MA-E | |
Wireless MA Remote Controller | □ TAR-FL32MA-E | |
Wireless Remote Contoller | □ PAR-SL101A-E | |
Wireless Signal Receiver Panel | □ PAR-SR4LU-E | |
Casement | Multi-function Casement | □ PAC-SJ41TM-E |
Condensate | Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor | |
(208/230V) [recommended] | □ X87-721 | |
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor | □ |
X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| □ C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| □ COMBI
Disconnect Switch
| (30A/600V/UL) [fits 2” X 4” utility box] – Black| □ TAZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| □ TAZ-MS303W
Filter| High Efficiency Filter Element**| □ PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| □ TLP-41EAEU
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| □
MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| □ MPLS385812T-65
Shutter Plate| Shutter Plate| □ PAC-SJ37SP-E
Space Panel| Space Panel| □ PAC-SJ38AS-E
NOTES:
- PAC-SF40RM-E (Unable to use with wireless remote controller)
INDOOR UNIT DIMENSIONS: TPLA0A0361EA80A
- FORM# TPLA0A0361EA80A – 202312
- Specifications are subject to change without notice.
- © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.