EUREKA 4380 Upright Vacuum Cleaner Owner’s Manual

June 17, 2024
Eureka

EUREKA-LOGO

EUREKA 4380 Upright Vacuum Cleaner

EUREKA-4380-Upright-Vacuum-Cleaner-PRODUCT

Product Information

  • Specifications:
    • Model: [Model]
    • Type: [Type]
    • Serial No.: [Serial No.]
    • Volts: [Volts]
    • Amps: [Amps]
    • Hertz: [Hertz]
  • General Information:
    • The cleaner is designed to pick up dirt and dust particles. Avoid picking up hard or sharp objects with the cleaner to prevent hose clogs.
  • Service Information:
    • The instructions in this booklet serve as a guide to routine maintenance.
    • For additional service information, please contact our toll-free number for the nearest Eureka Authorized Warranty Station. Please have the model, type, and serial numbers ready when you call.
    • USA: 1-800-282-2886
    • Mexico: 5670-6169
    • Canada: 1-800-282-2886
    • If you prefer, you can also write to The Eureka Company at the following addresses:
    • In the USA: The Eureka Company, Service Division, 807 North Main Street, Bloomington, Illinois 61701, USA.
    • In Canada: The Eureka Company, 866 Langs Drive, Cambridge, Ontario N3H 2N7.
    • Please refer to The Eureka Limited Warranty for complete service information.
  • Important Safeguards:
    • When using an electrical appliance, basic precautions should always be followed, including the following:
    • READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER.
    • Do not service the vacuum cleaner with wet hands.
    • If the vacuum cleaner is dropped into water, do not use it before returning it to a service center.
    • Do not run the vacuum cleaner over the cord and keep the cord away from heated surfaces.
    • Clean or replace filters regularly to maintain optimal performance.
    • Keep hands and body away from openings and moving parts.
    • Do not operate the vacuum cleaner in a storage position while using attachments.
    • Check and replace the belt as needed.
    • Please save these instructions for future reference.
  • How to Assemble:
    • CAUTION: Assemble the cleaner before using.
    • CAUTION: Make sure the on/off switch is in the off position before plugging in.
    • NOTE: Features may vary by model yet all parts assemble the same.

FAQs

  • Q: What should I do if I encounter assembly problems or have questions?
    • A: For assembly problems or questions, please contact Eureka’s Customer Service Division at 1-800-282-2886, Monday through Saturday, between 7 a.m. and 8 p.m., Central Standard Time.
  • Q: How can I get replacement parts?
    • A: For replacement of broken or missing items to be shipped directly to you, please call 1-800-438-7352, Monday through Friday, between 8 a.m. and 4:45 p.m., Central Standard Time.
  • Q: Can I use this product in Mexico?
    • A: Yes, for inquiries in Mexico, please call 5670-6169.

IMPORTANT SAFEGUARDS

When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER.

WARNING

To reduce the risk of fire, electric shock, or injury:

  • Do not use it outdoors or on wet surfaces.
  • Do not leave the vacuum cleaner when plugged in. Turn off the switch and unplug the electrical cord when not in use and before servicing.
  • Do not allow it to be used as a toy. Close attention is necessary when used by or near children.
  • Use only as described in this manual. Use only the manufacturer’s recommended attachments.
  • Do not use a damaged cord or plug. If the vacuum cleaner is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center before use.
  • Do not pull or carry by cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord. Keep the cord away from heated surfaces.
  • Do not use extension cords or outlets with inadequate current carrying capacity.
  • Turn off all controls before unplugging.
  • Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
  • Do not handle the plug or vacuum cleaner with wet hands.
  • Do not put any objects into openings. Do not use any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
  • This vacuum cleaner creates suction and contains a revolving brush roll. Keep hair, loose clothing, fingers, and all parts of the body away from openings and moving parts.
  • Do not place cleaner on furniture or stairs as the brush roll may cause damage. Place cleaner on the floor with the handle in the storage position while using attachments.
  • Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
  • Do not use it without a cyclonic cassette or filter(s) in place.
  • Belt pulleys can become hot during normal use. To prevent burns, avoid touching the belt pulley when servicing the drive belt.
  • Use extra care when cleaning on stairs.
  • Do not use to pick up flammable or combustible liquids such as gasoline, or use in areas where they may be present.
  • Store your cleaner indoors in a cool, dry area.
  • Keep your work area well-lighted.
  • Unplug electrical appliances before vacuuming them.

To reduce the risk of electric shock, this appliance has a polarized plug (one blade wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

GENERAL INFORMATION

  • The cleaner is designed to pick up dirt and dust particles.
  • Avoid picking up hard or sharp objects with the cleaner to prevent hose clogs.

Service Information

  • The instructions in this booklet serve as a guide to routine maintenance.
  • For additional service information telephone our toll-free number for the nearest Eureka Authorized Warranty Station.
  • You should know the model, type, and serial numbers when you call:
  • If you prefer, you can write to The Eureka Company, Service Division, 807 North Main Street, Bloomington, Illinois 61701, USA.
  • In Canada write to The Eureka Company, 866 Langs Drive, Cambridge, Ontario N3H 2N7. Refer to The Eureka Limited Warranty for complete service information.
  • DO NOT OIL the motor or the brush roll at any time. The bearings are permanently lubricated and sealed.

Rating Plate

  • The model, type, and serial numbers are indicated on the rating plate located on the back side of the cleaner.
  • For prompt and complete service information, always refer to these numbers when inquiring about service.
    • Model & Type__
    • Serial No. _____
    • MODEL TYPE SERIAL NO.
    • VOLTS AMPS. HERTZ
    • SERVICE INFORMATION: 1-800-282-2886
  • THE EUREKA COMPANY
    • BLOOMINGTON, ILLINOIS 61701
  • Thermal Cut Off
    • This vacuum cleaner has a special thermostat that protects the cleaner in case of motor overheating.
    • If the cleaner suddenly shuts off, push the switch pedal once and unplug the cleaner.
    • Check the cleaner for a possible source of overheating such as a full cyclonic cassette, a blocked hose, or a clogged filter.
    • If these conditions are found, fix them and wait at least 30 minutes before attempting to use the cleaner.
    • After 30 minutes, plug the cleaner back in and turn on the switch. If the cleaner still does not run, then take it to an Eureka Authorized Service Center for repair.

HOW TO ASSEMBLE

CAUTION: Assemble the cleaner before using.

CAUTION: Moving parts, make sure the on/off switch is in the off position before plugging in.

NOTE: Features may vary by model yet all parts assemble the same.

Step A Attach Hose

EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(1\)

  1. Locate the tab on the hose adapter of the extension hose (shortest end).
  2. Insert the hose adapter into the opening on top of the unit. The hose adapter tab must be placed down into the notch.
    • Step B Attach Handle
    • CAUTION: Do not catch the cord under the handle.EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(2\)
  3. From the rear of the cleaner, align the handle with the groove and slide onto the cleaner. If necessary, use the thumb and finger pressure to slide the handle into position.
  4. Once the handle is in place, check that the hose adapter tab is completely secure by pulling up on hose.
  5. Attach the handle with two 5/8 inch screws in the assembly packet. Use either a slotted or Phillips® head screwdriver.
    • Step C Store Hose and Accessories
    • Step D Store Electrical CordEUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(4\)
    • NOTE: For easier access to the bag compartment, when you store the electrical cord use a figure 8 pattern.
    • Step E-Check Cyclonic Cassette
    • Make sure that the cyclonic cassette is fully seated in the vacuum. Place thumbs on cyclonic cassette (marked by arrows above) and push firmly.
    • NOTE: Do not lift the cleaner by the cassette handle, use the carrying handle on the back of the cleaner. See the illustration in Step C.

HOW TO USE

The upright vacuum cleaner design allows use on multiple types of carpeting and upholstery or bare floors with attachments. When using the attachment tools, place the handle in the upright position. Do not place cleaner on furniture or steps as the brush roll may cause damage.

  1. Adjust the cleaner height setting knob to the lowest position for maximum cleaning. Adjust to a higher setting to make pushing easier. For easy adjustments, tilt the cleaner back to move the knob.
  2. Plug the electrical cord into the outlet.
  3. Step on handle release. Pull the handle back to a comfortable position.
  4. Push the On/Off power switch.

Cleaner Height Setting

  • WARNING: Avoid injury. Keep loose clothing, hair, fingers, and all other parts of the body away from any moving part (such as the revolving brush). Turn off the switch and unplug the cleaner before changing the cleaner height setting. The front of the cleaner has an adjustment that raises or lowers the cleaner base to match the type of carpet. With the cleaner cord unplugged, set the adjustment to the lowest setting for maximum cleaning. If the cleaner is difficult to push, move the adjustment to the next highest setting until the cleaner is comfortable to push. The brush roll must reach the carpet for effective cleaning.
  • NOTE: For ease in moving the adjustment knob, place the handle in the operating position and tilt the cleaner back to remove weight from the front wheels.
  • NOTE: When the handle is in an upright position, the brush roll is lifted off the carpet. This is normal. Height adjustment will not change the brush roll level until the cleaner’s handle is moved into the operating position.EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(8\)

THERMAL CUT OFF

This cleaner has a special thermostat that protects the cleaner in case of motor overheating. If the cleaner suddenly turns off, follow this procedure:

  1. Push the on/off pedal once.
  2. Unplug cleaner.
  3. Check for the source of the overheating problem (i.e. full cyclonic cassette, clogged hose or clogged filter).
  4. If a full cyclonic cassette, clogged hose, or clogged filter is found, empty the cyclonic cassette, unclog the hose or replace the filters.
  5. Wait at least 30 minutes before attempting to reuse the cleaner.
  6. After 30 30-minute cool-down period, plug the cleaner in and push the switch pedal. The cleaner should turn on.
  7. If the cleaner still does not operate, take it to any Eureka Authorized Service Center for repair.

How To Use Accessories

NOTE: Do not place cleaner on furniture or steps as the brush roll may cause damage. Place cleaner on the floor with the handle in the storage position while using accessories.

Depending on which cleaner you purchased, you can have any combination of the following accessories.

  1. Remove the hose from the rear of the cleaner.
  2. Place the desired accessory onto the end of the hose or wand.

Always work with the cleaner below you, pulling the hose from the side of the cleaner; not the back or the front of the cleaner.

EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(9\)

  • Dusting Brush is for furniture, blinds, books, lampshades, and shelves. (On some models.)
  • Upholstery Nozzle is for curtains, draperies, cushions, and fabrics. (On some models.)
  • Combination Tool gives two types of cleaning tools. (On some models.)
    • Use the brush side to dust furniture, blinds, books, lamps, and shelves.
    • Use upholstery side for curtains, draperies, cushions, and fabrics.
  • Crevice Tool cleans corners, baseboards, and cushions.
  • Extension Wands (Some models use 1 wand)
  • Nested Extension Wands to add reach.

STAIR CLEANING HOSE (Only on Certain Models)

WARNING: Never position any cleaner on the stairs as this could damage the carpet. Some models will come complete with an extra bonus hose which is ideal for cleaning stairs.

HOW TO ASSEMBLE AND USE

  • Step 1 – Remove the hose attached to the cleaner.
  • Step 2 Connect the hose cuff to the end of the bonus hose.
  • Step 3 – You are ready to clean your stairs.

WARNING

  • Always work with the cleaner below you, pulling the hose from the side of the cleaner; not the back or the front of the cleaner.
  • Ensure it is positioned sideways up against the bottom step.
  • NEVER STAND ANY CLEANER ABOVE YOU.
  • NEVER POSITION ANY CLEANER ON THE STAIRS AS THIS COULD DAMAGE THE CARPET.

Maintenance

Maintenance of Dirt Alert Feature (On some models)

  • The dirt alert sensor uses infrared technology to indicate whether or not floors are clean.
  • When debris breaks the light beam, the red light comes on indicating additional cleaning is needed in this area.
  • If there is no break in the light beam, the floor is clean and no light will come on.
  • When using your new vacuum you may be cleaning deep down hidden dirt missed by your old vacuum causing the light to stay red longer.
  • With frequent cleaning, after the first few times you use your new Eureka vacuum, the red light should go on less.
    • NOTE: The dirt alert feature is not intended to be used for above-the-floor cleaning with attachments.EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(21\)

How to Check the Dirt Alert Sensors

To check if the dirt sensor is working properly.

  1. While the red light is on, tip the vacuum backward on the rear wheels, lifting the brush roll off the carpet a couple of inches.
  2. After a few seconds, the red light should turn off.
    • HINT: New carpeting has loose carpet fibers which will trip the red light sensor beam.

HOW TO MAINTAIN

The instructions in this booklet serve as a guide to routine maintenance. To avoid unnecessary service calls, check the cyclonic cassette, belt, and brush roll often.

To Change Cassette Micron Filter:

NOTE: Turn off the switch and unplug the electrical cord before changing the Cassette Micron Filter. Never operate the vacuum cleaner without the cyclonic cassette or the filter.

Remove the cyclonic cassette by pushing up lever (1), and unhooking (2) by swinging outward from the vacuum body. When replacing the cyclonic cassette, hook at the top where shown (2), and swing back into place until lever (1) snaps into place.

Check and clean the Cassette Micron Filter once a month to maintain good performance. The filter can be cleaned by vacuuming with another cleaner or brushing dust off into the trash. Recommended changing of the Cassette Micron Filter is once every three months.

To Change the Cassette Micron Filter:

  1. Remove the filter frame by grasping the handle on the back of the filter frame and pulling firmly. The filter frame will drop down staying connected at the hinges on the bottom.

  2. Remove the old filter from filter frame and replace with a new filter.

  3. Reconnect the filter frame to the cassette body by swinging filter frame up and pushing against the cassette body until it snaps into place.

  4. Filter Frame

  5. Filter

  6. Cassette Body

Use GENUINE EUREKA replacement filter, 28115A. Look for the GENUINE EUREKA product symbol.

How To Empty Cyclonic Cassette
NOTE: Turn off the switch and unplug the electrical cord before emptying the cyclonic cassette. Never operate the vacuum cleaner without the cyclonic cassette or the filter. FOR INSTRUCTIONS ON HOW TO REMOVE THE CYCLONIC CASSETTE FROM THE CASSETTE BODY, REFER TO PAGE 11.

Emptying the Cyclonic Cassette:

  • It is visible when the dust compartment is full and needs emptying.
  • Lift the screen as shown (3) to empty the cyclonic cassette. It is possible to clean out the cyclonic cassette by using another vacuum.

CAUTION: The cyclonic cassette can be washed in warm water if desired, but strong detergents should not be used. Dry thoroughly before using again.

NOTE: The compartment with the screen (a) will fill much faster with larger dirt particles than the compartment with the cone (b). This is normal, empty the cyclonic cassette when the side with the screen is full, do not wait for the side with the cone to fill.

EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(25\)

Brush Roll

  • The brush roll turns as it sweeps and combs the carpet nap.
  • Remove hair and threads from the brush roll so it continues brushing the carpet.
  • To maintain the most efficient cleaning, the bristles must touch the carpet.
  • To test the bristle length, hold a ruler against the underside of the cleaner. If the bristles no longer touch the ruler, replace the brush roll.

Brush Roll Belt

  • The brush roll belt turns the brush roll to agitate, sweep, and comb the carpet nap.
  • Check the belt regularly to be sure it is in good condition.
  • Replace the belt if it stretches, cracks, or loses tension.
  • Cut away any hair or threads wound around the brush roll or the belt pulley because the buildup could cause the belt to rotate unevenly.

How To Replace Brush Roll Belt

NOTE: Turn off the switch and unplug the electrical cord before replacing the belt. Belt pulleys can become hot during normal use.  To prevent injury, avoid touching the motor pulley when checking the belt.

  1. Lower handle to floor to change belt.
  2. Loosen, but do not remove, two screws to release hood. Lift hood to remove.
  3. Lift left end of brush roll.
  4. Remove and discard belt.
  5. Place new belt around motor pulley.
  6. Place belt around brush roll pulley.
  7. Align left end cap with a square in base. Push the end cap into place; see left side view.
  8. Pull right side of the brush roll to stretch belt. Secure right end cap into base.
  9. Rotate brush roll to seat belt.
  10. Replace the hood. Make sure the hood front is behind the furniture guard. The hood should seat onto self-locating screw tabs.
  11. Tighten screws.

Use GENUINE EUREKA replacement belt, 54312. Look for the GENUINE EUREKA product symbol.

How to Clear Hose Clogs
Note: Turn off the switch and unplug the electrical cord before clearing the hose.

  1. Step on handle release.
  2. Lower the handle until the cleaner is flat on the floor.
  3. Turn the cleaner over so the back side faces up.
  4. Lift the cleaner and rest it against a support or counter.
  5. Pull upward on the attached wand portion of the hose assembly and remove it from the hose retainer.
  6. Check for clogs in the hose retainer and throughout the hose assembly.
  7. Use a tool that will not puncture the hose. Clear any debris from the hose retainer or the hose assembly that could restrict the air movement.
  8. Flexing the hose may help loosen the clog.
  9. After the clog is removed make sure the hose assembly and handle are reassembled onto the unit.
  10. If the clog is hard to remove, check the brush roll area. Remove the hood and clear the hose inlet in the brush roll area.EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(33\)

HEPA Cartridge Filters (Only for models with HEPA cartridges.)

Check the HEPA filters with each disposable dust bag change. Replace twice a year or after every six bag changes.

To remove HEPA cartridge filters

  1. Push down the latch and pull the filter cassette back.
  2. Then lift the filter and remove it.

To replace HEPA cartridge filters

  1. Place the bottom tabs of the filter cassette into slots.
  2. Rotate the filter toward cleaner.
  3. Push upward on the latch to secure it into place.
    • NOTE: To have the benefit of a sealed HEPA system, you must use one of the HEPA cartridge filter systems.

Filters in Filter Frame (Only for models with filter frame)
Check the filter each time the dust cup is emptied or as needed. Replace twice a year as needed.

To remove filters from the filter frame.

  1. Push down the latch and pull the filter frame back.
  2. Then lift the filter up and out of the filter frame.

To replace filters into filter frames.

  1. Place the new filter in the filter frame. Place the bottom tabs of the filter frame into slots.
  2. Rotate the filter frame toward the cleaner.
  3. Push upward on the latch to secure it into place.

Motor Filter
Check the motor filter with each disposable dust bag change. Clean or replace as needed.
To Clean the Motor Filter

  1. Remove the filter from the inside the bag compartment, lower left side.
  2. Shake the filter to remove excess dust. If necessary, the filter can be cleaned by vacuuming with another cleaner.
  3. Reinstall the filter with the stiff/printed side down. Slide under a back ledge and filter retainer. Install with colored/smooth side down.

Micron and HEPA Exhaust Filters (Only for models with the exhaust filter door) Change the micron or HEPA exhaust filter every 3 months.
To Replace Micron or HEPA exhaust filter

  1. Lower the handle. Open the exhaust filter door; push toward the left side.
  2. Grasp filter and pull out.
  3. Push the new filter into a cleaner, smooth side facing out.
  4. Close the exhaust filter door; push toward the right side. Replace all filters with genuine Eureka replacement filters.

How To Change Light Bulb (Only for models with a headlight)
NOTE: Turn off the power switch and disconnect the electrical cord before changing the light bulb.

  1. Lower handle. Remove two screws from the lens cover.
  2. Pull the lens cover from the cleaner.
  3. Pull the light bulb and socket toward the front.
  4. Push the light bulb into the socket; turn to release.
  5. Place the new light bulb into the socket; turn to secure.
  6. Push the light bulb and socket back so the bulb will not touch the lens cover.
  7. Replace the lens cover.
  8. Secure with two screws.EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(38\)
    • Use a 15-watt replacement light bulb, part number 48815.

PROBLEM-SOLVING

NOTE: Turn off the switch and unplug the electrical cord before servicing.

EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(39\)

LIMITED WARRANTY

THE EUREKA LIMITED WARRANTY

What This Warranty Covers

  • Your Eureka cleaner is warranted to be free from all defects in material and workmanship in normal household use for one year.
  • The warranty is granted only to the original purchaser and members of his or her immediate household. The warranty is subject to the following provisions.

What This Warranty Does Not Cover

  • Parts of the cleaner that require replacement under normal use, such as disposable dust bags, filters, drive belts, light bulbs, and brush roll bristles
  • Damages or malfunctions caused by negligence, abuse, or use not per the Owner’s Guide.
  • Defects or damages caused by unauthorized service or the use of other than Genuine Eureka parts.

What The Eureka Company Will Do

  • The Eureka Company will, at its option, repair or replace a defective cleaner or cleaner part that is covered by this warranty. As a matter of warranty policy, the Eureka Company will not refund the consumer’s purchase price.

Warranty Registration

  • Please fill out and return the warranty registration card accompanying your cleaner.

Obtaining Warranty Service

  • To obtain warranty service you must return the defective cleaner or cleaner part along with proof of purchase to any Eureka Authorized Warranty Station.
  • You will find the nearest location in the Yellow Pages, under “Vacuum Cleaners–Service and Repair.” Be certain that the Warranty Station is “Eureka Authorized.”
  • For the location of the nearest Eureka Authorized Warranty Station or service information, telephone toll-free:
    • USA: 1-800-282-2886
    • Mexico: 5670-6169
    • Canada: 1-800-282-2886
    • If you prefer, you can write to The Eureka Company, Service Division, 807 North Main Street, Bloomington, Illinois 61701, USA. In Canada write to The Eureka Company, 866
    • Langs Drive, Cambridge, Ontario N3H 2N7.
    • If it is necessary to ship the cleaner outside your community to obtain warranty repair, you must pay the shipping charges to the Eureka Authorized Warranty Station.
    • Return shipping charges will be paid by the Warranty Station. When returning parts for repair, please include the model, type, and serial number from the data plate on the cleaner.

Further Limitations and Exclusions

  • Any warranty that may be implied in connection with your purchase or use of the cleaner, including any warranty of Merchantability or any warranty for Fitness For A Particular
  • The purpose is limited to the duration of this warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
  • Your relief for the breach of this warranty is limited to the relief expressly provided above.
  • In no event shall Eureka be liable for any consequential or incidental damages you may incur in connection with your purchase or use of the cleaner.
  • Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
  • This warranty gives you specific legal rights. You may also have other rights which vary by state.

GENUINE EUREKA PRODUCT

Questions & Answers about Genuine Eureka Products

  • Q: Why should I use only Genuine Eureka paper bags, belts, and parts in my Eureka vacuum cleaner?
    • A: Using Genuine Eureka Products, which are made to our exacting specifications and engineered with an emphasis on quality, performance, and customer satisfaction, ensures the long life and cleaning efficiency of your vacuum cleaner. Overall, this saves you money and helps to keep your home clean.
  • Q: How can I be sure I am using only genuine Eureka products in my vacuum cleaner?
    • A: Typically, packaged products and paper bags can be identified by a “Genuine Eureka Product” symbol (see illustration above). For further identification assistance, you may call our toll-free number, 1-800-282-2886, for the location of a nearby Eureka Authorized Warranty Station.
  • Q: Are there any differences between “made to fit” or “imitation” and Genuine Eureka paper bags, belts, and parts?
    • A: Yes, there are some very important differences in materials, quality, and reliability. Many customers have mistakenly purchased “imitation” paper bags and parts while thinking they purchased genuine. Unfortunately, many of these customers discovered the differences after they experienced related difficulties.
    • For Genuine Eureka Value, Accept No Imitations!
    • THE EUREKA COMPANY
    • Bloomington, Illinois 61701

SOLD TO

EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(43\)

SHIP TO
EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(44\)

IMPORTANT: Be sure to include your model, type, and serial numbers. These numbers may be found on the rating plate.

  • Model Number:
  • Type:
  • Serial Number:
  • To Order By Phone 1-800- 438-7352*
  • HOURS: Call between 8 a.m. and 4:45 p.m., central standard time Monday through Friday.
  • By FAX 1-309- 823-5789
  • To Answer Problems or Questions for the U.S.A. and Canada call: 1-800- 282-2886*
  • 7 a.m. to 8 p.m. central standard time Monday through Saturday.
  • En Mexico llame all 5670-6169
  • By Mail: Simply fill out this Order Form. Please be sure to include day and evening phone numbers.
  • www.eureka.com.EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(40\)EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(45\)
  • Questions? Do Not Return To Store
  • Call 1-800-282-2886 7 a.m. to 8 p.m., Central Standard Time, Monday through Saturday

Accessory Items in This Carton

EUREKA-4380-Upright-Vacuum-Cleaner-FIG-1 \(42\)

Thank you for selecting an Eureka cleaner.

Don’t Forget to Use Genuine Eureka Belts

  • Caution: Damages caused by the use of non-genuine Eureka parts are not covered by the Eureka Limited Warranty.
  • Part No. 70239B (10/01) Printed in U.S.A.
  • ©1999 White Consolidated Industries, Inc.
  • Upright Vacuum Cleaner Owner’s Guide 4380 – 4480 Series

IMPORTANT

  • Do not return this product to the store.
  • For assembly problems or questions contact: Eureka’s Customer Service Division toll-free at 1-800-282-2886*, 7 a.m. to 8 p.m., Central Standard
  • Time, Monday through Saturday.
  • For replacement of broken or missing items to be shipped direct to you, call 1-800-438-7352, 8 a.m. to 4:45 p.m., Central Standard Time, Monday through Friday. En Mexico llame al 5670-6169
  • www.eureka.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>