GENIUS Lynx 04 24V Central Panel Board
Product Information
General Characteristics
The LLYYNNXX 0033 is a versatile product designed for automated system
installations. It is equipped with various features to ensure safety and
efficient operation.
Technical Specifications
- Control unit power supply: 24Vdc
- Absorbed power: 500mA
- Motor max. load: 24Vdc, 15W max.
- Accessories max. load: 24Vdc, 15W max.
- Flashing lamp max. load: 24Vdc
- Max load of courtesy light/indicator-light: 24Vdc
- Operating ambient temperature: N/A
- Protection fuses: N/A
- Function logics: Automatic/Stepped
- Opening/closing time: By self-learning at installation
- Pause time: By self-learning at installation
- Thrust force: Two selectable levels
- Deceleration time: 1.5 or 3 selectable seconds
Terminal Board Inputs
- Radio connector
Terminal Board Outputs
- Rapid connector 5 pins
- 24 Vdc power supply to accessories
- 24Vdc motor
- 24 Vdc Flashing lamp
- 24Vdc Indicator – Courtesy light
Characteristics of Toroidal Transformer 230V~
N/A
Characteristics of Toroidal Transformer 115V~
N/A
Characteristics of Optional Batteries
N/A
Characteristics of Outdoor Enclosure
N/A
Product Usage Instructions
Installation Instructions
- Before starting the installation, read the instructions carefully.
- Ensure that packing materials such as plastic and polystyrene are not accessible to children, as they can be potential sources of danger.
- Store these instructions for future reference.
- This product is designed for specific use as indicated in the documentation. Any other use can compromise its operation and pose a safety risk.
- GENIUS is not liable for improper use or use other than intended.
- Avoid installing the equipment in an explosive atmosphere.
- Ensure that mechanical parts conform to the relevant safety standards.
- Before performing any work on the system, cut off electrical power.
- The installation must comply with the applicable safety standards.
- Follow the recommended power supply and wiring connections specified in the instructions.
Maintenance Instructions
N/A
Troubleshooting Instructions
N/A
FAQ
-
Q: Can I install the equipment in an explosive atmosphere?
A: No, it is not recommended to install the equipment in an explosive atmosphere as it poses a serious safety risk. -
Q: What should I do before attempting any work on the system?
A: Cut off the electrical power to ensure safety before performing any work on the system.
IMPORTANT NOTICE FOR THE INSTALLER
GENERAL SAFETY REGULATIONS
-
ATTENTION! To ensure the safety of people, you must read all the following instructions. Incorrect installation or incorrect use of the product could cause serious harm to people.
-
Carefully read the instructions before beginning to install the product.
-
Do not leave packing materials (plastic, polystyrene, etc.) within reach of children as such materials are potential sources of danger.
-
Store these instructions for future reference.
-
This product was designed and built strictly for the use indicated in this documentation. Any other use, not expressly indicated here, could compromise the good condition/operation of the product and/or be a source of danger.
-
GENIUS declines all liability caused by improper use or use other than that for which the automated system was intended.
-
Do not install the equipment in an explosive atmosphere: the presence of inflammable gas or fumes is a serious danger to safety.
-
The mechanical parts must conform to the provisions of Standards EN 12604 and EN 12605.
For non-EU countries, to obtain an adequate level of safety, the Standards mentioned above must be observed, in addition to national legal regulations. -
GENIUS is not responsible for failure to observe Good Technique in the construction of the closing elements to be motorized, or for any deformation that may occur during use.
-
The installation must conform to Standards EN 12453 and EN 12445. The safety level of the automated system must be C+E.
-
Before attempting any job on the system, cut out electrical power.
-
The mains power supply of the automated system must be fitted with an all-pole switch with a contact opening distance of 3mm or greater. The use of a 6A thermal breaker with an all-pole circuit break is recommended.
-
Make sure that a differential switch with a threshold of 0.03 A is fitted upstream of the system.
-
Make sure that the earthing system is perfectly constructed, and connect metal parts of the means of the closure to it.
-
The automated system is supplied with an intrinsic anti-crushing safety device consisting of a torque control. Nevertheless, its tripping threshold must be checked as specified in the Standards indicated at point 10.
-
The safety devices (EN 12978 standard) protect any dangerous areas against mechanical movement Risks, such as crushing, dragging, and shearing.
-
Use of at least one indicator light is recommended for every system, as well as a warning sign adequately secured to the frame structure, in addition to the devices mentioned at point 16.
-
GENIUS declines all liability as concerns safety and efficient operation of the automated system if system components not produced by GENIUS are used.
-
For maintenance, strictly use original parts by GENIUS.
-
Do not in any way modify the components of the automated system.
-
The installer shall supply all information concerning the manual operation of the system in case of an emergency and shall hand over to the user the warnings handbook supplied with the product.
-
Do not allow children or adults to stay near the product while it is operating.
-
Keep remote controls or other pulse generators away from children, to prevent the automated system from being activated involuntarily.
-
Transit through the leaves is allowed only when the gate is fully open.
-
The user must not attempt any kind of repair or direct action and contact qualified personnel only.
-
Anything not expressly specified in these instructions is not permitted.
CONTROL BOARD FOR BARRIERS 24 Vdc
OPERATING INSTRUCTIONS
INSTALLATION INSTRUCTIONS
GENERAL CHARACTERISTICS
Thanks to its high-powered microprocessor, this control unit for 24 Vdc
automatic barriers, offers a wide range of functions and adjustments,
including deceleration and motor control.
A sophisticated electronic control monitors the power circuit at all times and
disables the control unit in the event of malfunctions that could impair the
efficiency of the electronic clutch.
Main settings and function modes are executed by dip switches, whereas the
timing, and also power of the motor are adjusted through self-learning at
installation. 8 built-in LEDs constantly indicate the status of both the
control unit and gearmotor.
TECHNICAL SPECIFICATIONS
Control unit power supply | 24V- (+6 -10%) 50 / 60 Hz |
---|---|
Absorbed power | 3W |
**otor max. load** | 80W |
Accessories max. load | 24Vdc 500mA |
Flashing lamp max. load | 24Vdc 15W max. |
**ax load of courtesy light indicator light** | 24Vdc 15W |
max.
Operating ambient temperature| -20°C +50°C
Protection fuses| 2
Function logics| Automatic / Stepped
Opening closing time| By self-learning at installation
Pause time| By self-learning at installation
Thrust force| Two selectable levels
Deceleration time| 1.5 or 3 selectable seconds
Terminal board inputs
| 24 V- power supply – / Battery power supply / Opening and closing limit-
switch / START / STOP / CLOSE / Opening and closing safety devices
Radio connector| Rapid connector 5 pins
Terminal board outputs| 24 Vdc power supply to accessories /
24Vdc motor / 24 Vdc Flashing lamp 24Vdc / Indicator – Courtesy light
Control board dimensions| 90 x 175 mm.
Characteristics of toroidal transformer 230V~|
Prim.230V- / Sec. 22V- / 80VA
Characteristics of toroidal transformer 115V~|
Prim.115V- / Sec. 20V- / 80VA
Characteristics of optional batteries| 12V / 4 Ah / dimens.
90 x 70 x 108 mm.
Characteristics of outdoor enclosure| 305 x 225 x 125 mm.
IP55
Attention : different output values on voltage 24V~ are possible according to the mains voltage. Before starting, always check the transformer output voltage. It shall not exceed 26V~ both for the 230V~ power supply and 115V~ power supply. Voltage is to be measured loadless, i.e. when the transformer is supplied with power but disconnected from the board.
INSTRUCTIONS
WARNING : To ensure people’s safety, all warnings and instructions in this booklet must be carefully observed. Incorrect installation or use of the product could cause serious harm to people.
- Make sure there is an adequate differential switch upstream of the system as specified by current Standards, and install a thermal breaker with an all-pole switch on the electric mains.
- To lay electric cables, use adequate rigid and/or flexible tubes.
- Always separate connection cables of low voltage accessories from those operating at 115 / 230 V~.
- To prevent any interference whatever, use separate sheaths.
Fitting the buffer batteries
Observe the following instructions to fit the buffer batteries (optional) (see
fig.1):
- Place the battery support, Ref. A, behind the fastening cross piece of the spring (Ref. B) and fix it with both M5 screws supplied.
- Position the batteries (optional) and if necessary secure them employing plastic clamps (not supplied).
Note : The support has been designed to house 2 batteries having the characteristics and dimensions specified in the table of paragraph 2.
CONNECTIONS AND OPERATION
TERMINAL BOARD M1
24V power supply
Terminals 1-2 This is the input to which the secondary winding of the
transformer, powered at 24 V~ 50/60 Hz, should be connected. When power is
supplied by the transformer, this is signaled by the POWER LED lighting up.
Batteries
- Terminals 3-4. The control unit is designed to operate with two buffer batteries (optional item) with minimum characteristics as indicated on the table in paragraph 2. When powered, the control unit keeps the batteries charged.
- The batteries begin to operate when the transformer no longer supplies power.
N.B.: power supplied by batteries should be considered an emergency the number of possible operations depends on the quality of the batteries, the structure to be moved, and time elapsing since mains power failed, etc, etc..
N.B.: observe the power polarity of the batteries
Accessories
- Terminals 5-6. Output for powering external accessories (24 Vdc).
NB.: Maximum load of accessories is 500 mA.
NB.: observe power supply polarity
Gearmotor
Terminals 7-8. Connect the motor to a power supply of 24Vdc 80W max.
TERMINAL BOARD M2
Earthing
Terminal 9. Connect the mains earth cable.
N.B.: This connection is essential to ensure the control unit operates
correctly
Opening limit-switch
Terminals 10-11. The status of this input is signaled by the FCA LED. Connect
the limit switch activating the opening movement. The effect differs depending
on the programming affected with dip-switch 3. If not using the limit switch,
jump the input.
Closing limit-switch
Terminals 10-12. The status of this input is signaled by the FCC LED. Connect
the limit switch activating the closing movement. If not using the limit
switch, jump the input..
Flashing lamp
Terminals 13-14. Use a flashing light with a steady light (flashing is
produced by the control unit) on the operating voltage of 24 Vdc 15W max. It
is useful to connect it before programming, as it indicates its phases. It
produces a pre-flashing steady light for 0.5 seconds when opening, and for 1.5
seconds when closing. If the automatic logic is ON, when it reaches the
opening stop-point, the flashing light stays on with a steady light for 5 sec
signaling to the user that it will close automatically. When the gate is open,
the flashing light is OFF, and only flashes when the safety devices are
engaged for a maximum time of 10 sec, after which the flashing light goes OFF
even with the safety devices engaged.
Indicator-light/Courtesy light
Terminals 13-15. This terminal is in parallel with the lamp-holder on the
card. Use a 24Vdc 15W max lamp. The effect differs depending on the
programming affected with dip-switch 7.
TERMINAL BOARD M3
Close
Terminals 16-21. The status of this input is signaled by the CLOSE LED. Any
device (e.g. push-button, radio control, etc.) can be connected to this
circuit. By closing a contact, the circuit generates a pulse for the total
closing of the gate.
Start
Terminals 17-21. The status of this input is signaled by the START LED. Any
device (e.g. push-button, radio control, etc.) can be connected to this
circuit. By closing a contact, the circuit generates a pulse for the total
opening and/or closing of gate. Its operating mode is set by dip-switch 5.
Closing Photocells
Terminals 18-21. The status of this input is signaled by the FTC LED. Any
safety device (e.g. photocells, safety edge, etc.) can be connected to this
circuit. By opening a contact, the circuit protects the closing motion.
N.B.: If safety devices are not connected, fit a jumper at input. To install
several safety devices, connect the NC contacts in series.
Stop
Terminals 19-21. The status of this input is signaled by the STP LED. Any
device (e.g. push-button, pressure switch, etc.) can be connected to this
circuit. By opening a contact, the circuit stops gate movement. The set cycle
will restart only if a successive opening or closing pulse is received.
N.B.: If STOP devices are not connected, fit a jumper at input. To install
several STOP devices, connect the NC contacts in series.
Opening Photocells
Terminals 20-21. The status of this input is signaled by the FTO LED. Any
safety device (photocells, safety edges, etc.) can be connected to this
circuit, which, by opening a contact, has a safety effect on the opening
motion.
N. B.: If no safety devices are connected, fit a jumper at the input. To
install several safety devices, connect the NC contacts in series.
FITTING A REMOTE CONTROL RECEIVER CARD
The control unit is designed to house a 5-pin radio-receiver module.
Installation procedure: turn off the power and fit the module on connector M5
inside the control unit.
ATTENTION : To avoid damaging the receiver and thus irreparably
jeopardizing its operation, the receiver must be fitted while observing
the direction specified in paragraph 9 (Connection layout).
This is done, by observing the receiver instructions on the memory storage of
the remote control. When the remote control has been stored, it acts just like
any command device on START.
CONTROL LEDS
LED | LIGHTED | OFF |
---|---|---|
POWER – power supply | **ains power** | No power or batteries |
FCA – opening limit-switch | Disengaged | Engaged |
FCC – closing limit-switch | Disengaged | Engaged |
CLOSE | Engaged | Disengaged |
START | Engaged | Disengaged |
FTC – closing safety device | Disengaged | Engaged |
STP – stop | Disengaged | Engaged |
FTO – opening safety device | Disengaged | Engaged |
N.B.: LED status is shown in bold when the automated system is closed and the control unit is powered.
PROGRAMMING
NB.: Programming must be done while the control unit is powered off the mains, through the transformer. Programming is not possible by using the buffer batteries only. This ensures that all times and functions of the control unit are correctly programmed. Programming of work times, deceleration, and electronic clutch is executed in self-learning. At this stage, leaf movement is at a slow speed. Procedure:
- Release the automated system, take it to about midway through opening travel, and then lock it.
- Power up the control unit (power ON is signaled by the POWER LED).
- Turn switch S2 to PROG: the flashing lamp goes on at a steady light to signal programming.
- Press the push-button connected to the START terminals or the remote-control, if data has been stored. The first operation the automated system performs must be CLOSING.
- If the application moves to open, touch the two RESET pins with a screwdriver the control unit will immediately stop the movement generated by the automated system.
- Cut power to the control unit, reverse polarity of the two cables powering the motor, and repeat the operation at point 1.
- After the START command is given, the automated system moves to close, until it reaches the closing stop or limit switch if supplied.
- After about two seconds, the automated system restarts opening automatically until it reaches the opening stops or limit switch if supplied.
- The control unit begins counting pause time. After the required time has elapsed, press the START command again, and the automated system will close completely.
- The programming is now finished. Turn switch S2 back to OFF the flashing lamp goes off.
FUSES
FUSE | SAFETY DEVICE | FUSE | SAFETY DEVICE |
---|---|---|---|
F1 =T10A250V – 5×20 | Motor /Power supply | F2 =F3.15/250V – 5×20 |
Logic/ Accessories output
OPERATIONAL DIAGRAM
TABLE 1: FUNCTION LOGICS AND SETTINGS
| SW1| SW2| SW3| SW4| SW5| SW6| SW7|
SW8
---|---|---|---|---|---|---|---|---
Electronic clutch
Maximum force, minimum sensitivity
| |
ON
| | | | | | |
Minimum force, maximum sensitivity| | OFF| | | | | | |
Automatic closing| | | | | | | | |
ON| | | ON| | | | | |
OFF| | | OFF| | | | | |
Deceleration on opening limit switch
ON, from limit-switch forward
| | | |
ON
| | | | |
OFF, immediate stop at limit-switch| | | | OFF| | | | |
Condo operation
Not accepting START on opening and pause
| | | | |
ON
| | | |
OFF| | | | | OFF| | | |
START command operation
Opens – stop – closes – stop – opens -….
| | | | | |
ON
| | |
Opens – closes – opens – closes -…..| | | | | | OFF| | |
Deceleration time| | | | | | | | |
3 seconds| | | | | | | ON| |
1.5 seconds| | | | | | | OFF| |
Courtesy light selection light
Courtesy light goes off after 90 sec
| | | | | | | |
ON
|
Light ON during opening, pause and closing| | | | | | | | OFF|
Limit switch selection
Both limit-switches installed
| | | | | | | | |
ON
No limit-switch or opening limit-switch only| | | | | | | | | OFF
| 8| | | | | | | |
The descriptions and illustrations contained in the present manual are not binding. GENIUS reserves the right, whilst leaving the main features of the types of equipment unaltered, to undertake any modifications to holds necessary for either technical or commercial reasons, at any time and without revising the present publication.
Distributors stamp:
GENIUS S.p.A.
Via Padre Elzi, 32 24050 – Grassobbio BERGAMO-ITALY tel. 0039.035.4242511 fax.
0039.035.4242600 info@geniusg.com
www.geniusg.com